scholarly journals Absence of Relationship between Mitochondrial DNA Haplogroups and Cisplatin-Induced Hearing Loss

2017 ◽  
Vol 2017 ◽  
pp. 1-5 ◽  
Author(s):  
D. Graterol ◽  
C. Mir ◽  
C. Garcia-Vaquero ◽  
I. Braña ◽  
A. N. Pardo ◽  
...  

Background. Many drugs used for cancer chemotherapy produce reactive oxygen species, thus leading to various complications including nephrotoxicity, cardiotoxicity, and ototoxicity. Objective. We have provided a haplogroup analysis of a cohort of cancer patients treated with chemotherapy and compared factors associated with associated hearing loss. Study Design and Methods. This observational cohort study includes a pure-tone audiometry of the patients who underwent chemotherapeutic treatment. Medical history, presence of risk factors for hearing loss, toxic habits, and association with haplogroups have been determined. Results. 40% of patients developed hearing loss after administration of cisplatin, which was bilateral and symmetrical and of high frequencies. The most frequent haplogroup was H with a slight overexpression of groups V and K and a low frequency of groups J and T. No association of the haplogroup types with the hearing loss has been found; however age was revealed as an important determining factor. Conclusions. Ototoxicity caused by cisplatin is manifested as bilateral, symmetrical, and predominantly high frequency hearing loss. Although we did not find a strong correlation of haplogroups with ototoxicity, our results revealed the existence of a risk group of elderly patients over 60, which are more susceptible to hearing loss induced by cisplatin, than young adults, regardless of preexisting hearing loss.

2013 ◽  
Vol 127 (10) ◽  
pp. 952-956 ◽  
Author(s):  
A Goyal ◽  
P P Singh ◽  
A Vashishth

AbstractObjectives:This study aimed to: understand the effect that high intensity noise associated with drilling (during otological surgery) has on hearing in the contralateral ear; determine the nature of hearing loss, if any, by establishing whether it is temporary or persistent; and examine the association between hearing loss and various drill parameters.Methods:A prospective clinical study was carried out at a tertiary centre. Thirty patients with unilateral cholesteatoma and normal contralateral hearing were included. Patients were evaluated pre-operatively and for five days following surgery using high frequency pure tone audiometry, and low and high frequency transient evoked and distortion product otoacoustic emission testing.Results:The findings revealed statistically significant changes in distortion product otoacoustic emissions at high frequencies (p = 0.016), and in transient evoked otoacoustic emissions at both low and high frequencies (p = 0.035 and 0.021, respectively). There was a higher statistical association between otoacoustic emission changes and cutting burrs compared with diamond burrs.Conclusion:Drilling during mastoid surgery poses a threat to hearing in the contralateral ear due to noise and vibration conducted transcranially.


2015 ◽  
Vol 2015 ◽  
pp. 1-5 ◽  
Author(s):  
Veronika Vielsmeier ◽  
Astrid Lehner ◽  
Jürgen Strutz ◽  
Thomas Steffens ◽  
Peter M. Kreuzer ◽  
...  

Objective. The majority of tinnitus patients suffer from hearing loss. But a subgroup of tinnitus patients show normal hearing thresholds in the conventional pure-tone audiometry (125 Hz–8 kHz). Here we explored whether the results of the high frequency audiometry (>8 kHz) provide relevant additional information in tinnitus patients with normal conventional audiometry by comparing those with normal and pathological high frequency audiometry with respect to their demographic and clinical characteristics.Subjects and Methods. From the database of the Tinnitus Clinic at Regensburg we identified 75 patients with normal hearing thresholds in the conventional pure-tone audiometry. We contrasted these patients with normal and pathological high-frequency audiogram and compared them with respect to gender, age, tinnitus severity, pitch, laterality and duration, comorbid symptoms and triggers for tinnitus onset.Results. Patients with pathological high frequency audiometry were significantly older and had higher scores on the tinnitus questionnaires in comparison to patients with normal high frequency audiometry. Furthermore, there was an association of high frequency audiometry with the laterality of tinnitus.Conclusion. In tinnitus patients with normal pure-tone audiometry the high frequency audiometry provides useful additional information. The association between tinnitus laterality and asymmetry of the high frequency audiometry suggests a potential causal role for the high frequency hearing loss in tinnitus etiopathogenesis.


2003 ◽  
Vol 14 (09) ◽  
pp. 525-533 ◽  
Author(s):  
Owen D. Murnane ◽  
John K. Kelly

Click-evoked otoacoustic emission (CEOAE) input/output (I/O) functions were measured in ears with normal hearing and in ears with sensorineural hearing loss above 2000 Hz. The low- to midfrequency CEOAEs obtained from the ears with high-frequency hearing loss were significantly reduced in level compared to the CEOAEs obtained from the ears with normal hearing even though there were no significant group differences in the 250–2000 Hz pure-tone thresholds. The findings are discussed within the context of two hypotheses that explain the low- to midfrequency reduction in transient-evoked otoacoustic emission (TEOAE) magnitude: (1) subclinical damage to the more apical regions of the cochlea not detected by behavioral audiometry, or (2) trauma to the basal region of the cochlea that affects the generation of low-frequency emissions. It is proposed that localized damage at basal cochlear sites affects the generation of low- to midfrequency CEOAE energy.


Author(s):  
Nzanzu Kikuhe ◽  
Heather Hume ◽  
Emily Kakande ◽  
Justine Namwagala

<p class="abstract"><strong>Background:</strong> A case control was carried out to study the prevalence, the pattern and associated factors of hearing loss among Ugandan children with sickle cell anaemia.</p><p class="abstract"><strong>Methods:</strong> One hundred and thirty-two children known sickle cell and one hundred thirty aged matched non-SCA controls were recruited after medical ethics committee approval and informed consent. Two obtain information on socio-demographic characteristics, history, and examination of the participants, a structured questionnaire was administered. Pure tone audiometry (PTA) was used to assess the hearing in a sound-treated room.  </p><p class="abstract"><strong>Results:</strong> Twenty-two of the children had hearing impairment compared to 6 controls. Prevalence of hearing loss found among children with SCA was 17% but in the control group the prevalence found was 5%. Sensorineural hearing loss (SNHL) affected 39%, conductive (CHL) 25% and mixed (MHL) 14% among cases compared to CHL 7%, SNHL 7% and MHL 7% among the controls. The hearing loss varied from mild to moderate (95%). All sickle cell children had high-frequency hearing loss. There was a statistically significant association of hearing loss and neurologic motor deficit.</p><p class="abstract"><strong>Conclusions:</strong> Sickle patients are at risk of developing hearing loss as the study demonstrated a difference in hearing threshold in children living with sickle cell anaemia and the controls. High frequencies were more affected. The neurologic motor deficit was highly associated with hearing loss among patients with SCA compared to controls.</p>


2015 ◽  
Vol 123 (4) ◽  
pp. 1059-1064 ◽  
Author(s):  
Parthasarathy Thirumala ◽  
Andrew M. Frederickson ◽  
Jeffrey Balzer ◽  
Donald Crammond ◽  
Miguel E. Habeych ◽  
...  

OBJECT Microvascular decompression is a safe and effective procedure to treat hemifacial spasm, but the operation poses some risk to the patient’s hearing. While severe sensorineural hearing loss across all frequencies occurs at a low rate in experienced hands, a recent study suggests that as many as one-half of patients who undergo this procedure may experience ipsilateral high-frequency hearing loss (HFHL), and as many as one-quarter may experience contralateral HFHL. While it has been suggested that drill-related noise may account for this finding, this study was designed to examine the effect of a number of techniques designed to protect the vestibulocochlear nerve from operative manipulation on the incidence of HFHL. METHODS Pure-tone audiometry was performed both preoperatively and postoperatively on 67 patients who underwent microvascular decompression for hemifacial spasm during the study period. A change of greater than 10 dB at either 4 kHz or 8 kHz was considered to be HFHL. Additionally, the authors analyzed intraoperative brainstem auditory evoked potentials from this patient cohort. RESULTS The incidence of ipsilateral HFHL in this cohort was 7.4%, while the incidence of contralateral HFHL was 4.5%. One patient (1.5%; also included in the HFHL group) experienced an ipsilateral nonserviceable hearing loss. CONCLUSIONS The reduced incidence of HFHL in this study suggests that technical modifications including performing the procedure without the use of fixed retraction may greatly reduce, but not eliminate, the occurrence of HFHL following microvascular decompression for hemifacial spasm.


2015 ◽  
Vol 123 (6) ◽  
pp. 1500-1506 ◽  
Author(s):  
Parthasarathy Thirumala ◽  
Kristin Meigh ◽  
Navya Dasyam ◽  
Preethi Shankar ◽  
Kanika R. K. Sarma ◽  
...  

OBJECT The primary aim of this study was to evaluate the incidence and discuss the pathogenesis of high-frequency hearing loss (HFHL) after microvascular decompression (MVD) for trigeminal neuralgia (TGN), glossopharyngeal neuralgia (GPN), or geniculate neuralgia (GN). METHODS The authors analyzed preoperative and postoperative audiogram data and brainstem auditory evoked potentials (BAEPs) from 93 patients with TGN, 6 patients with GPN, and 8 patients with GN who underwent MVD. Differences in pure tone audiometry > 10 dB at frequencies of 0.25, 0.5, 1, 2, 4, and 8 kHz were calculated preoperatively and postoperatively for both the ipsilateral and the contralateral sides. Intraoperative monitoring records were analyzed and compared with the incidence of HFHL, which was defined as a change in pure tone audiometry > 10 dB at frequencies of 4 and 8 kHz. RESULTS The incidence of HFHL was 30.84% on the side ipsilateral to the surgery and 20.56% on the contralateral side. Of the 47 patients with HFHL, 20 had conductive hearing loss, and 2 experienced nonserviceable hearing loss after the surgery. The incidences of HFHL on the ipsilateral side at 4 and 8 kHz were 17.76% and 25.23%, respectively, and 8.41% and 15.89%, respectively, on the contralateral side. As the audiometric frequency increased, the number of patients with hearing loss increased. No significant postoperative difference was found between patients with and without HFHL in intraoperative BAEP waveforms. Sex, age, and affected side were not associated with an increase in the incidence of hearing loss. CONCLUSIONS High-frequency hearing loss occurred after MVD for TGN, GPN, or GN, and the greatest incidence occurred on the ipsilateral side. This hearing loss may be a result of drill-induced noise and/or transient loss of cerebrospinal fluid during the course of the procedure. Changes in intraoperative BAEP waveforms were not useful in predicting HFHL after MVD. Repeated postoperative audiological examinations may be useful in assessing the prognosis of HFHL.


AAOHN Journal ◽  
1998 ◽  
Vol 46 (2) ◽  
pp. 67-75 ◽  
Author(s):  
Oi Saeng Hong ◽  
Shu-Pi C. Chen ◽  
Karen M. Conrad

The purposes of this study of airport workers were to a) determine the prevalence and symptoms of hearing loss, and b) identify compliance in using hearing protective devices (HPDs) and its relationship with hearing loss. This cross sectional epidemiological study was conducted with 255 noise exposed and 195 non-noise exposed, full time, male workers at a large metropolitan airport in Seoul, Korea. The three measures used were the self administered Occupational Hearing Questionnaire (OHQ), an audiological assessment, and a record review of baseline hearing and noise levels of locations in which the employee worked. The results showed a significant difference in prevalence of hearing loss (more than 25dB) between the noise and the non-noise exposed groups ( p < .05). About 60.8% of noise exposed workers reported continuous use of the HPDs. The continuous HPD users had significantly lower rates of hearing loss than the occasional users or non-users. The major symptom for workers with low frequency hearing loss was trouble in communication, whereas tinnitus and fullness in the ear were the most common symptoms for the workers with high frequency hearing loss. The airport workers exposed to excessive noise had a great deal of high frequency hearing loss. The degree of hearing loss present reinforces the need for aggressive hearing conservation programs among airport workers exposed to noise.


2016 ◽  
Vol 32 (6) ◽  
pp. 416-422 ◽  
Author(s):  
Deepa L. Sekhar ◽  
Thomas R. Zalewski ◽  
Jessica S. Beiler ◽  
Beth Czarnecki ◽  
Ashley L. Barr ◽  
...  

High frequency hearing loss (HFHL), often related to hazardous noise, affects one in six U.S. adolescents. Yet, only 20 states include school-based hearing screens for adolescents. Only six states test multiple high frequencies. Study objectives were to (1) compare the sensitivity of state school-based hearing screens for adolescents to gold standard sound-treated booth testing and (2) consider the effect of adding multiple high frequencies and two-step screening on sensitivity/specificity. Of 134 eleventh-grade participants (2013–2014), 43 of the 134 (32%) did not pass sound-treated booth testing, and 27 of the 43 (63%) had HFHL. Sensitivity/specificity of the most common protocol (1,000, 2,000, 4,000 Hz at 20 dB HL) for these hearing losses was 25.6% (95% confidence interval [CI] = [13.5, 41.2]) and 85.7% (95% CI [76.8, 92.2]), respectively. A protocol including 500, 1,000, 2,000, 4,000, 6,000 Hz at 20 dB HL significantly improved sensitivity to 76.7% (95% CI [61.4, 88.2]), p < .001. Two-step screening maintained specificity (84.6%, 95% CI [75.5, 91.3]). Adolescent school-based hearing screen sensitivity improves with high frequencies.


2021 ◽  
Vol 3 (1) ◽  
pp. 005-008
Author(s):  
Kiran Naik ◽  
Ravi KS ◽  
Pragati

Background: Hearing loss is often thought of as a natural phenomenon of the aging process. However younger people with repeated usage of ear phone music are reporting nowadays with hearing impairment and more during this COVID pandemic era. In today’s society, these devices are indispensable and are part of day‑to‑day life and because of the restriction on outdoor movement in COVID pandemic more and more people are reliant on ear phone music to allay boredom. Hence, this study was conducted to create awareness regarding prolonged exposure to loud noise either through an MP3 player or cell phone music. Materials and Methods: A prospective study was done compromising 400 students from Shri Adichunchanagiri Institute of Medical Sciences from March 2020 to December 2020. They were divided into four groups using a questionnaire, Group A comprising 100 students who had a habit of listening to music through ear phones at least 2 h a day, Group B comprising 100 students who are used to earphone music less than 1 h per day and Group C comprising of 100 students who very occasionally use ear phones, but hear music mostly through speakers and Group D comprising of 100 students who are not used to ear phone music. All the 400 students studied were attending online classes as per the college schedule which constituted 3-4 hours daily. All the groups were subjected to pure tone audiometry when they reported back to their regular offline classes as the pandemic reduced in January 2021 and the audiogram obtained. Results and Observations: The study revealed high frequency hearing loss in 6% of Group A and 2% in Group B; whereas, in there were no hearing impairment in Groups C and D indicating a significant role of prolonged ear phone music as a cause of high frequency hearing loss in students. The thin percentage and absence of hearing loss in Groups B, C, and D suggests the impact of the duration of exposure also has a role in the pathology. Conclusion: This study proves beyond doubt that the prolonged usage of loud ear phone music is harmful to the ears and also the COVID induced movement restriction precipitated the indiscriminate use of ear phone music which further increased the causation.


Sign in / Sign up

Export Citation Format

Share Document