scholarly journals Magnetoimpedance Effect in CoFeMoSiB As-Quenched and Surface Modified Amorphous Ribbons in the Presence of Igon Oxide Nanoparticles of Water-Based Ferrofluid

2017 ◽  
Vol 2017 ◽  
pp. 1-9
Author(s):  
Zahra Lotfollahi ◽  
Ahmad Amirabadizadeh ◽  
Aleksander P. Safronov ◽  
Igor V. Beketov ◽  
Galina V. Kurlyandskaya

Giant magnetoimpedance (GMI) has been proposed as a powerful technique for biosensing. In GMI biosensors based on the magnetic label detection the change of the impedance of sensitive element under the application of an external magnetic field was analyzed in the presence of magnetic nanoparticles in a test solution. Amorphous ribbon-based GMI biodetectors have an advantage of low operation frequency and low cost. In this work, magnetic and GMI properties of amorphous Co68.6Fe3.9Mo3.0Si12.0B12.5 ribbons were studied in as-quenched and surface modified states both without and in the presence of maghemite ferrofluid. After the surface modification the coercivity was slightly increased and saturation magnetization decreased in good agreement with increase of the surface roughness, a decrease of magnetic elements concentrations in the surface layer, and formation of a surface protective oxide layer. The GMI difference for as-quenched ribbons in absence and in the presence of ferrofluid was measurable for the frequency range of 2 to 10 MHz and the current intensities of 1 to 20 mA. Although the proposed surface modification by the ultrasound treatment did not improve the sensitivity limit for ferrofluid detection, it did not decrease it either.

2020 ◽  
Author(s):  
Ali Lesani ◽  
Somaieh Kazemnejad ◽  
Hengameh Mousavi ◽  
Iman Ramazani Sarbandi ◽  
Mahdi Moghimi Zand

Abstract The employment of Nanotechnology as a valuable tool could be beneficial to patients and also offer new alternatives for Assisted Reproductive Technology (ART). Surface modification by nanoparticles leads to the alteration of surface characteristics (e.g. roughness, elasticity, and surface charge). These alterations affect sperm behavior especially its motility since sperms exhibit wall following behavior and surface accumulation. Moreover, surface modification is an attempt towards mimicking the complex in vivo environment of the female tract (highly folded and ciliated) with continually changing surface topology and also its functions. In this paper, we present the results of investigating the interactions between sperm cells and surface modified substrates using Nano diamond particles. A combinational and low-cost method was used for modification. The results show that the sperm motility parameters are significantly improved from 5 to 85%. Also, the results indicate that in optimized surface modification condition, the sperms swim faster and straighter and the surface facilitates the swimming due to the inherent characteristics of ND particles. Taken together, the replacement of normal with modified surfaces in fertility-aid microfluidic devices can enhance their efficiency and further improve their outcomes.


2018 ◽  
Vol 185 ◽  
pp. 10003
Author(s):  
Zahra Lotfollahi ◽  
Ahmad Amirabadizadeh ◽  
Alexander P. Safronov ◽  
Galina V. Kurlyandskaya

Giant magnetoimpedance (GMI) effect is a powerful technique for magnetic label detection. Co-based amorphous ribbons are cheap materials showing high GMI effect at low operation frequencies for close to zero magnitostriction compositions. In this work magnetic properties and GMI were studied for CoFeMoSiB amorphous ribbons in as-quenched and surface modified states without and in the presence of water-based ferrofluid with electrostatic stabilization of γ-Fe2O3 nanoparticles. Surface modification by ultrasound treatment resulted in appearance of round defects with average diameter of about 150 micrometers. The GMI difference for as-quenched ribbons in absence and in the presence of ferrofluid was measured for the frequency range of 0.5 to 10 MHz. Although proposed surface modification by the ultrasound treatment did not improve the sensitivity limit for ferrofluid detection, it did not decrease it either. Observed changes of GMI are useful for understanding of functionality of GMI biosensors.


2018 ◽  
Vol 185 ◽  
pp. 10001 ◽  
Author(s):  
Elizaveta V. Golubeva ◽  
Anna A. Chlenova ◽  
Elena A. Stepanova ◽  
Galina V. Kurlyandskaya

Fe3Co66Cr3Si16B12 and Fe6Co60Ni10Si14B10 amorphous ribbons were surface modified in toluene at room temperature. Such a treatment resulted in deposition of thin carbon-based layer. As a result of the carbon covering deposition the stress distribution in the near-surface layers was changed due to partial compensation of the initial quenching stresses. Comparative analysis of magnetic and magnetoimpedance properties of as-quenched and surface modified ribbons confirms changes in effective magnetic anisotropy as a result of surface treatment. An increase of the corrosion resistance of the ribbons with carbon covering can be useful for the development amorphous ribbon based magnetic biosensor.


2020 ◽  
pp. 53-58
Author(s):  
A. V. Koudelny ◽  
I. M. Malay ◽  
V. A. Perepelkin ◽  
I. P. Chirkov

The possibility of using bolometric converters of microwave power from the State primary standard of the unit of power of electromagnetic waves in waveguide and coaxial paths GET 167-2017, which has a frequency range from 37,5 to 78,33 GHz, in an extended frequency range up to 220 GHz, is shown. Studies of semiconductor bolometric converters of microwave power in an extended frequency range have confirmed good agreement and smooth frequency characteristics of the effective efficiency factor of the converters. Based on the research results, the State working standard of the unit of power of electromagnetic waves of 0,1–10 mW in the frequency range from 37,5 to 220 GHz 3.1.ZZT.0288.2018 was approved. The technical characteristics of the working standard of the unit of power of electromagnetic oscillations in an extended frequency range from 37,5 to 220 GHz are given.


2020 ◽  
Vol 27 (10) ◽  
pp. 1616-1633 ◽  
Author(s):  
Oana Cristina Duta ◽  
Aurel Mihail Ţîţu ◽  
Alexandru Marin ◽  
Anton Ficai ◽  
Denisa Ficai ◽  
...  

Polymeric materials, due to their excellent physicochemical properties and versatility found applicability in multiples areas, including biomaterials used in tissue regeneration, prosthetics (hip, artificial valves), medical devices, controlled drug delivery systems, etc. Medical devices and their applications are very important in modern medicine and the need to develop new materials with improved properties or to improve the existent materials is increasing every day. Numerous reasearches are activated in this domain in order to obtain materials/surfaces that does not have drawbacks such as structural failure, calcifications, infections or thrombosis. One of the most used material is poly(vinylchloride) (PVC) due to its unique properties, availability and low cost. The most common method used for obtaining tubular devices that meet the requirements of medical use is the surface modification of polymers without changing their physical and mechanical properties, in bulk. PVC is a hydrophobic polymer and therefore many research studies were conducted in order to increase the hydrophilicity of the surface by chemical modification in order to improve biocompatibility, to enhance wettability, reduce friction or to make lubricious or antimicrobial coatings. Surface modification of PVC can be achieved by several strategies, in only one step or, in some cases, in two or more steps by applying several techniques consecutively to obtain the desired modification / performances. The most common processes used for modifying the surface of PVC devices are: plasma treatment, corona discharge, chemical grafting, electric discharge, vapour deposition of metals, flame treatment, direct chemical modification (oxidation, hydrolysis, etc.) or even some physical modification of the roughness of the surface.


2016 ◽  
Vol 34 (1) ◽  
Author(s):  
Walter Sydney Dutra Folly ◽  
Aracy Sousa Senra

ABSTRACT. We describe the construction and testing of a simple and efficient low-cost resistivimeter designed for use in practical classes in Applied Geophysics. The equipment was successfully tested in a vertical electrical sounding (VES) performed on sandy terrain within the campus of the Universidade Federal de Sergipe, Brazil. The VES results were in good agreement with the profiles obtained from two boreholes located approximately 500 m from the test area, clearly demonstrating the efficiency of the equipment and the adopted methodology.Keywords: vertical electrical sounding, electrical resistivity, resistivity profile. RESUMO. Neste artigo, descrevemos a construção e o teste de um resistivímetro de baixo custo, simples e eficiente, concebido para ser utilizado em aulas práticas de Geofísica Aplicada. O equipamento foi testado com a realização de uma sondagem elétrica vertical (SEV) em um terreno arenoso localizado no campus da Universidade Federal de Sergipe, Brasil. Os resultados obtidos nesta SEV apresentaram boa concordância com os perfis observados em dois poços de sondagem localizados a 500 m da área de teste, fato que comprovou a eficiência do equipamento e da metodologia adotada.Palavras-chave: sondagem elétrica vertical, resistividade elétrica, perfil de resistividade. 


2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Min Liu ◽  
Hongmei Li ◽  
Yangsu Zeng

Tungsten trioxide (WO3) was surface modified with Cu(II) nanoclusters and titanium dioxide (TiO2) nanopowders by using a simple impregnation method followed by a physical combining method. The obtained nanocomposites were studied by scanning electron microscope, X-ray photoelectron spectroscopy spectra, UV-visible light spectra, and photoluminescence, respectively. Although the photocatalytic activity of WO3was negligible under visible light irradiation, the visible light photocatalytic activity of WO3was drastically enhanced by surface modification of Cu(II) nanoclusters and TiO2nanopowders. The enhanced photocatalytic activity is due to the efficient charge separation by TiO2and Cu(II) nanoclusters functioning as cocatalysts on the surface. Thus, this simple strategy provides a facile route to prepare efficient visible-light-active photocatalysts for practical application.


1999 ◽  
Author(s):  
Mitsuteru Kimura ◽  
Katsuhisa Toshima ◽  
Harunobu Satoh

Abstract A new type all optical vibration and acceleration sensor using the combination of micromachined Si cantilever and optical fiber is proposed, and its fundamental characteristics are demonstrated. The light emitted from bulb-lens set into the V-groove is reflected at the reflector formed on the Si cantilever and then recoupled into the bulb-lens. Several sensors with different length (0.64–6.0 mm long) of the Si cantilever are fabricated to compare the theoretical resonance frequency fr obtained from the simple model and experimental ones. They had good agreement. From the sensing principle the sensing frequency range of the vibration is suitable below the fr of the Si cantilever of the sensor.


1977 ◽  
Vol 32 (1) ◽  
pp. 57-60 ◽  
Author(s):  
H. E. Gunilla Knape ◽  
Lena M. Torell

Abstract Brillouin spectra of molten CSNO3 were investigated for scattering angles between 40 and 140° and in a temperature interval of 420-520 °C. An Ar+ singlemode laser was used for excitation and the total instrumental width was ~265 MHz. The measured frequency shifts and linewidths of the Brillouin components were used to determine velocities and attenuations of thermal sound waves in the frequency range 2.3-7.0 GHz. A dispersion of 4-5% was found between the present hyper­ sonic velocities and reported ultrasonic velocities. A considerable decrease in attenuation with frequency was observed in the investigated frequency range, with the value at high frequency ap­ proaching the classical attenuation. The results are in good agreement with Mountain's theory of a single relaxation time. The relaxation time of the bulk viscosity coefficient was calculated to 1.2×10-10S.


2021 ◽  
Vol 21 (4) ◽  
pp. 291-298
Author(s):  
Chandana SaiRam ◽  
Damera Vakula ◽  
Mada Chakravarthy

In this paper, a novel compact broadband antenna at UHF frequencies is presented with canonical shapes. Hemispherical, conical and cylindrical shapes have all been considered for antenna configuration. The designed antenna provides an instantaneous frequency range from 370 to 5,000 MHz with omnidirectional characteristics. The antenna was simulated in CST Microwave Studio, fabricated and evaluated; the results are presented. The simulated and measurement results are in good agreement. The antenna has voltage standing wave ratio (VSWR) ≤ 1.9:1 in 400–570 MHz, 2,530–3,740 MHz and 4,180–4,620 MHz; it has VSWR ≤ 3:1 over the operating frequency range 370–5,000 MHz and the measured gain varies from -0.6 to 4.5 dBi over the frequency band. The concept of canonical-shaped antenna elements and the incorporation of triple sleeves resulted in a reduction of the length of the antenna by 62% compared to the length of a half-wave dipole antenna designed at the lowest frequency. The antenna can be used for trans-receiving applications in wireless communication.


Sign in / Sign up

Export Citation Format

Share Document