scholarly journals Fibered Confocal Fluorescence Microscopy for the Noninvasive Imaging of Langerhans Cells in Macaques

2017 ◽  
Vol 2017 ◽  
pp. 1-8 ◽  
Author(s):  
Biliana Todorova ◽  
Nina Salabert ◽  
Sabine Tricot ◽  
Raphaël Boisgard ◽  
Mélanie Rathaux ◽  
...  

Purpose. We developed a new approach to visualize skin Langerhans cells by in vivo fluorescence imaging in nonhuman primates. Procedures. Macaques were intradermally injected with a monoclonal, fluorescently labeled antibody against HLA-DR molecule and were imaged for up to 5 days by fibered confocal microscopy (FCFM). Results. The network of skin Langerhans cells was visualized by in vivo fibered confocal fluorescence microscopy. Quantification of Langerhans cells revealed no changes to cell density with time. Ex vivo experiments confirmed that injected fluorescent HLA-DR antibody specifically targeted Langerhans cells in the epidermis. Conclusions. This study demonstrates the feasibility of single-cell, in vivo imaging as a noninvasive technique to track Langerhans cells in nontransgenic animals.

2015 ◽  
Vol 309 (6) ◽  
pp. L543-L551 ◽  
Author(s):  
Frédéric Chagnon ◽  
Alexandra Bourgouin ◽  
Réjean Lebel ◽  
Marc-André Bonin ◽  
Eric Marsault ◽  
...  

The pathophysiology of acute lung injury (ALI) is well characterized, but its real-time assessment at bedside remains a challenge. When patients do not improve after 1 wk despite supportive therapies, physicians have to consider open lung biopsy (OLB) to identify the process(es) at play. Sustained inflammation and inadequate repair are often observed in this context. OLB is neither easy to perform in a critical setting nor exempt from complications. Herein, we explore intravital endoscopic confocal fluorescence microscopy (ECFM) of the lung in vivo combined with the use of fluorescent smart probe(s) activated by myeloperoxidase (MPO). MPO is a granular enzyme expressed by polymorphonuclear neutrophils (PMNs) and alveolar macrophages (AMs), catalyzing the synthesis of hypoclorous acid, a by-product of hydrogen peroxide. Activation of these probes was first validated in vitro in relevant cells (i.e., AMs and PMNs) and on MPO-non-expressing cells (as negative controls) and then tested in vivo using three rat models of ALI and real-time intravital imaging with ECFM. Semiquantitative image analyses revealed that in vivo probe-related cellular/background fluorescence was associated with corresponding enhanced lung enzymatic activity and was partly prevented by specific MPO inhibition. Additional ex vivo phenotyping was performed, confirming that fluorescent cells were neutrophil elastase+(PMNs) or CD68+(AMs). This work is a first step toward “virtual biopsy” of ALI without OLB.


2007 ◽  
Vol 6 (2) ◽  
pp. 7290.2007.00004 ◽  
Author(s):  
Marie-Sophie Martina ◽  
Jean-Paul Fortin ◽  
Laure Fournier ◽  
Christine Ménager ◽  
Florence Gazeau ◽  
...  

2017 ◽  
Vol 142 (3) ◽  
pp. 396-401 ◽  
Author(s):  
Savitri Krishnamurthy ◽  
Andrea Cortes ◽  
Mirtha Lopez ◽  
Michael Wallace ◽  
Sharjeel Sabir ◽  
...  

Context.— Optical imaging techniques are currently available for imaging tissues without the need for any type of extensive tissue preparation. There are several applications for their potential use in surgical pathology practice. Objective.— To evaluate the feasibility of using a confocal fluorescence microscopy (CFM) platform for ex vivo examination of tissues obtained from surgical resections of breast, lung, kidney, and liver. Design.— Tissue fragments (0.5–1.0 cm) were immersed in 0.6 mM acridine orange for 6 seconds and imaged using a CFM platform at a 488-nm wavelength. The imaged tissues were subsequently fixed in formalin and processed routinely to generate hematoxylin-eosin–stained tissue sections. Mosaics of the grayscale CFM images were studied at different magnifications for recognition of the tissue and were compared with conventional histopathologic examination of hematoxylin-eosin tissue sections. Results.— We imaged 55 tissue fragments obtained from 16 breast (29%), 18 lung (33%), 14 kidney (25%), and 7 liver (13%) surgical excision specimens. Acridine orange labeled the nuclei, creating the contrast between nucleus and cytoplasm and thereby recapitulating the tissue architecture. We could obtain CFM images of good quality within 5 to 10 minutes that allowed recognition of the cytomorphologic details for categorization of the imaged tissue and were similar to histologic examination of hematoxylin-eosin tissue sections. Conclusions.— The ease and speed of acquisition of CFM images together with the resolution and resemblance of the CFM images to hematoxylin-eosin sections suggest that the CFM platform has excellent potential for use in surgical pathology practice.


Sign in / Sign up

Export Citation Format

Share Document