scholarly journals The Effect of Photovoltaic Panels on the Rooftop Temperature in the EnergyPlus Simulation Environment

2016 ◽  
Vol 2016 ◽  
pp. 1-12 ◽  
Author(s):  
Changhai Peng ◽  
Jianqiang Yang

In this paper, the effects that photovoltaic (PV) panels have on the rooftop temperature in the EnergyPlus simulation environment were investigated for the following cases: with and without PV panels, with and without exposure to sunlight, and using roof materials with different thermal conductivities and for different climatic zones. The results demonstrate that heat transfer by convection, radiation, and conduction in the air gaps between PV panels and the building envelope can be simulated in the EnergyPlus environment when these air gaps are in the “air conditioning zone.” Nevertheless, in most cases, particularly on the rooftop, the air gaps between the PV panels and the building envelope cannot be set as the “air conditioning zone.” Therefore, in this case, none of the EnergyPlus models are appropriate to simulate the effect that PV panels have on the rooftop temperature. However, all the terms of the Heat Balance Model, including the absorbed direct and diffuse solar radiation, net long-wave radiation with the air and surroundings, convective exchange with the outside air, and conduction flux in or out of the surface, can still be used to calculate the temperature and heat flux within the BIPV’s air gap.

2014 ◽  
Vol 472 ◽  
pp. 1047-1051
Author(s):  
Tian Jian Yang ◽  
Yang Li

In order to evaluate the energy-saving effect of Distributed Cooling System (DCS) analytically, the heat balance model of DCS in a TBS is established and then dynamic simulation is employed. The numeral results show that DCS has much better energy-saving effect than traditional air conditioning (AC) and the energy-saving effect is steady all year round.


Atmosphere ◽  
2021 ◽  
Vol 12 (4) ◽  
pp. 524
Author(s):  
Jihui Yuan ◽  
Kazuo Emura ◽  
Craig Farnham

The Typical meteorological year (TMY) database is often used to calculate air-conditioning loads, and it directly affects the building energy savings design. Among four kinds of TMY databases in China—including Chinese Typical Year Weather (CTYW), International Weather for Energy Calculations (IWEC), Solar Wind Energy Resource Assessment (SWERA) and Chinese Standard Weather Data (CSWD)—only CSWD is measures solar radiation, and it is most used in China. However, the solar radiation of CSWD is a measured daily value, and its hourly value is separated by models. It is found that the cloud ratio (diffuse solar radiation divided by global solar radiation) of CSWD is not realistic in months of May, June and July while compared to the other sets of TMY databases. In order to obtain a more accurate cloud ratio of CSWD for air-conditioning load calculation, this study aims to propose a method of refining the cloud ratio of CSWD in Shanghai, China, using observed solar radiation and the Perez model which is a separation model of high accuracy. In addition, the impact of cloud ratio on air-conditioning load has also been discussed in this paper. It is shown that the cloud ratio can yield a significant impact on the air conditioning load.


2018 ◽  
Vol 40 (2) ◽  
pp. 220-236 ◽  
Author(s):  
Irfan Ahmad Gondal

This study presents an innovative concept of a compact integrated solar-thermoelectric module that can form part of the building envelope. The heating/cooling modes use the photovoltaic electrical current to power the heat pump. The experimental analysis was carried out and the results of coefficient of performance were in the range 0.5–1 and 2.6–5 for cooling and heating functions, respectively. The study demonstrates that thermoelectric cooler can effectively be used for heating, ventilation, and air conditioning applications by integrating with solar panels especially in cooling applications. The system is environmentally friendly and can contribute in the implementation of zero energy buildings concept. Practical application: In order to help address the challenge of climate change and associated environmental effects, there is continuous demand for new technologies and applications that can be readily integrated into day-to-day life as a means of reducing anthropogenic impact. Heating, ventilation, and air conditioning, as one of the largest energy consumers in buildings, is the focus of many researchers seeking to reduce building energy use and environmental impact. This article proposes using facades and windows that have an integrated modules of solar photovoltaic cells and thermoelectric devices that are able to work together to achieve heating and cooling effects as required by the building without requiring any external operational power.


2005 ◽  
Vol 36 (4-5) ◽  
pp. 381-396 ◽  
Author(s):  
A. Rutgersson ◽  
A. Omstedt ◽  
Y. Chen

In this paper, which reports on part of the BALTEX project, various components of the heat balance over the Baltic Sea are calculated using a number of gridded meteorological databases. It is the heat exchange between the Baltic Sea surface and the atmosphere that is of interest. The databases have different origins, comprising synoptic data, data re-analysed with a 3D assimilation system, an ocean model forced with gridded synoptic data, ship data and satellite data. We compared the databases and found that the greatest variation between them is in the long- and short-wave radiation values. However, considerable upward long-wave radiation is followed by considerable downward short-wave radiation, so the total radiation component is partly compensated for in the total budget. The variation in the total heat transport in the databases therefore appears smaller (1.5±3 W m−2) as the average and one standard deviation. The turbulent heat fluxes estimated from satellite data have very low values; this can largely be explained by the method of calculating air temperature, which also produces an unrealistic stratification over the Baltic Sea. The ERA40 data was compared with measured values: there, we found a certain land influence even in the centre of the Baltic proper. The indicated turbulent heat fluxes were too large, mainly in the fall and winter, and the sensible heat flux was too large in a downward direction in spring and summer.


Buildings ◽  
2021 ◽  
Vol 11 (10) ◽  
pp. 491
Author(s):  
Jorge González ◽  
Carlos Alberto Pereira Soares ◽  
Mohammad Najjar ◽  
Assed N. Haddad

Linking Building Information Modelling and Building Energy Modelling methodologies appear as a tool for the energy performance analysis of a dwelling, being able to build the physical model via Autodesk Revit and simulating the energy modeling with its complement Autodesk Insight. A residential two-story house was evaluated in five different locations within distinct climatic zones to reduce its electricity demand. Experimental Design is used as a methodological tool to define the possible arrangement of results emitted via Autodesk Insight that exhibits the minor electric demand, considering three variables: Lighting efficiency, Plug-Load Efficiency, and HVAC systems. The analysis concluded that while the higher the efficiency of lighting and applications, the lower the electric demand. In addition, the type of climate and thermal characteristics of the materials that conform to the building envelope have significant effects on the energetic performance. The adjustment of different energetic measures and its comparison with other climatic zones enable decision-makers to choose the best combination of variables for developing strategies to lower the electric demand towards energy-efficient buildings.


2016 ◽  
Vol 20 (3) ◽  
pp. 827-830
Author(s):  
Lijuan Wang ◽  
Yuhui Di ◽  
Hui Yin ◽  
Yanfeng Liu ◽  
Jiaping Liu

The objectives of the paper are to analyze human convection, radiation, evaporation, respiration, conduction, and diffusion heat losses when the operative temperature increases from 26-34.4?C and then decreases from 34.4-26?C with a ratio of 1.4?C per 5 minutes. A energy balance model is used for sedentary subject. The results show that during temperature rising, all the heat losses are linear functions of temperature, while during temperature dropping, the convection, diffusion, and respiration heat losses are quadratic functions of temperature. The results are useful for thermal comfort evaluation and heating, ventilation, and air conditioning design.


2009 ◽  
Vol 48 (4) ◽  
pp. 693-715 ◽  
Author(s):  
Toru Kawai ◽  
Mohammad Kholid Ridwan ◽  
Manabu Kanda

Abstract The authors’ objective was to apply the Simple Urban Energy Balance Model for Mesoscale Simulation (SUMM) to cities. Data were selected from 1-yr flux observations conducted at three sites in two cities: one site in Kugahara, Japan (Ku), and two sites in Basel, Switzerland (U1 and U2). A simple vegetation scheme was implemented in SUMM to apply the model to vegetated cities, and the surface energy balance and radiative temperature TR were evaluated. SUMM generally reproduced seasonal and diurnal trends of surface energy balance and TR at Ku and U2, whereas relatively large errors were obtained for the daytime results of sensible heat flux QH and heat storage ΔQS at U1. Overall, daytime underestimations of QH and overestimations of ΔQS and TR were common. These errors were partly induced by the poor parameterization of the natural logarithm of the ratio of roughness length for momentum to heat (κB−1); that is, the observed κB−1 values at vegetated cities were smaller than the simulated values. The authors proposed a new equation for predicting this coefficient. This equation accounts for the existence of vegetation and improves the common errors described above. With the modified formula for κB−1, simulated net all-wave radiation and TR agreed well with observed values, regardless of site and season. However, at U1, simulated QH and ΔQS were still overestimated and underestimated, respectively, relative to observed values.