scholarly journals Microelectrical Impedance Spectroscopy for the Differentiation between Normal and Cancerous Human Urothelial Cell Lines: Real-Time Electrical Impedance Measurement at an Optimal Frequency

2016 ◽  
Vol 2016 ◽  
pp. 1-10 ◽  
Author(s):  
Yangkyu Park ◽  
Hyeon Woo Kim ◽  
Joho Yun ◽  
Seungwan Seo ◽  
Chang-Ju Park ◽  
...  

Purpose. To distinguish between normal (SV-HUC-1) and cancerous (TCCSUP) human urothelial cell lines using microelectrical impedance spectroscopy (μEIS). Materials and Methods. Two types of μEIS devices were designed and used in combination to measure the impedance of SV-HUC-1 and TCCSUP cells flowing through the channels of the devices. The first device (μEIS-OF) was designed to determine the optimal frequency at which the impedance of two cell lines is most distinguishable. The μEIS-OF trapped the flowing cells and measured their impedance at a frequency ranging from 5 kHz to 1 MHz. The second device (μEIS-RT) was designed for real-time impedance measurement of the cells at the optimal frequency. The impedance was measured instantaneously as the cells passed the sensing electrodes of μEIS-RT. Results. The optimal frequency, which maximized the average difference of the amplitude and phase angle between the two cell lines (p<0.001), was determined to be 119 kHz. The real-time impedance of the cell lines was measured at 119 kHz; the two cell lines differed significantly in terms of amplitude and phase angle (p<0.001). Conclusion. The μEIS-RT can discriminate SV-HUC-1 and TCCSUP cells by measuring the impedance at the optimal frequency determined by the μEIS-OF.

Author(s):  
Oliver Power ◽  
Adam Ziolek ◽  
Andreas Elmholdt Christensen ◽  
Andrei Pokatilov ◽  
Anca Nestor ◽  
...  

The core objective of EMPIR project 17RPT04 VersICaL is to improve the European measurement infrastructure for electrical impedance, with particular emphasis on the capabilities of developing NMIs and calibration centres. The project will seek to exploit the results of existing research on digital impedance bridges (DIBs) by designing, constructing and validating simple, affordable versions suitable to realise the impedance scale in the range 1 nF to 10 μF and 1 mH to 10 H with relative uncertainties in the range 10-5 to 10-6. The first results of the research project, including the bridge designs and details of a polyphase digitally synthesized multichannel source capable of providing voltage outputs of precise ratio and phase are presented.


1995 ◽  
Vol 89 (1) ◽  
pp. 81-87 ◽  
Author(s):  
Ruey-Long Hong ◽  
Yeong-Shiau Pu ◽  
Jan-Show Chu ◽  
Wei-Jei Lee ◽  
Yao-Chang Chen ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document