scholarly journals Clinical Acceptability of the Internal Gap of CAD/CAM PD-AG Crowns Using Intraoral Digital Impressions

2016 ◽  
Vol 2016 ◽  
pp. 1-6
Author(s):  
Tae-Gyung Kim ◽  
Sungtae Kim ◽  
Hyunmin Choi ◽  
Jae-Hoon Lee ◽  
Jae-Hong Kim ◽  
...  

The purpose of this study was to compare the internal gap between CAD/CAM palladium-silver crowns and cast gold crowns generated from intraoral digital versus conventional impressions and to determine the clinical acceptability. Nickel-chrome master dies were made from the prepared resin tooth with the conventional impression method (n=40). For ICC (Intraoral, CAD/CAM) group, 10 intraoral digital impressions were made, and 10 CAD/CAM crowns of a PD-AG (palladium-silver) machinable alloy were generated. For IC (Intraoral, Cast) group, 10 gold crowns were cast from ten intraoral digital impressions. For CCC (Conventional, CAD/CAM) group, 10 CAD/CAM PD-AG crowns were made using the conventional impression method. For CC (Conventional, Cast) group, 10 gold crowns were fabricated from 10 conventional impressions. One hundred magnifications of the internal gaps of each crown were measured at 50 points with an optical microscope and these values were statistically analyzed using a two-way analysis of variance (α=0.05). The internal gap of the intraoral digital impression group was significantly larger than in the conventional impression group (P<0.05). No significant difference was observed between the CAD/CAM group and the cast group (P>0.05). Within the limitations of this in vitro study, crowns from intraoral digital impressions showed larger internal gap values than crowns from conventional impressions.

2020 ◽  
Vol 19 ◽  
pp. e207286
Author(s):  
Kamila Aguiar Figueiredo Alves ◽  
Janaina Emanuela Damasceno ◽  
Viviane Maia Barreto de Oliveira ◽  
Luiz Gustavo Cavalcanti Bastos ◽  
Andrea Nóbrega Cavalcanti

Aim: This study evaluated the precision of a CAD/CAM system by measuring marginal, internal and proximal fits in implantsupported single-crown restorations. Methods: Ten models of the upper arch were made in which implants replaced the upper left premolars. For fabrication of the zirconia infrastructures, titanium bases (TiBase) were coded and scanned using a scan body. A second digital impression was made for the fabrication of prostheses. Silicone impression material was used to determine the internal clearance between the TiBase and infrastructure and between the infrastructure and crown, whose thickness was measured at three points [P1 (cervical), P2 (middle) and P3 (occlusal)] with a stereoscopic microscope at 70x and 100x magnification. One-way ANOVA for repeated measures and the Student t-test were used for the analysis of internal and marginal adaptation. Proximal contacts were analyzed qualitatively. Results: There was no significant difference between the teeth evaluated (Student’s t-test; p>0.05) or between the corresponding points evaluated in either tooth (one-way ANOVA; p>0.05). Analysis of the internal clearance between the infrastructure and crown demonstrated that all points were significantly different compared to the reference standardized at 100 μm (Student’s t-test p<0.0001). There was no significant difference between P1 and P2, with the thickness at these two points being lower than that obtained at P3 (one-way ANOVA, p<0.05). The proximal contacts did not coincide with the quality defined by the device. Conclusion: The system tested was unable to produce implantsupported single-crown ceramic restorations with marginal, internal and proximal fits matching the digital workflow, with the inferior fits requiring adjustment prior to cementation.


2021 ◽  
Vol 11 (24) ◽  
pp. 12034
Author(s):  
Mohammed E. Sayed ◽  
Abdulkarim Hussain Alshehri ◽  
Bandar M. A. Al-Makramani ◽  
Fuad Al-Sanabani ◽  
Fawzia Ibraheem Shaabi ◽  
...  

Accurate impression-making is considered a vital step in the fabrication of fixed dental prostheses. There is a paucity of studies that compare the casts generated by various impression materials and techniques that are commonly used for the fabrication of provisional and definitive fixed prostheses. The aim of this study is to compare the accuracy of casts obtained using conventional impression and digital impression techniques. Thirty impressions were made for the typodont model (10 impressions each of polyvinyl siloxane, alginate, and alginate alternative materials). Ten digital models were printed from the same model using a TRIOS-3 3Shape intraoral scanner. Accuracy was assessed by measuring four dimensions (horizontal anteroposterior straight, horizontal anteroposterior curved, horizontal cross-arch, and vertical). A one-way ANOVA and Tukey’s test (α = 0.05) were used to analyze data. A statistically significant difference in the four dimensions of the stone casts and digital models was observed among the four groups (exception: between alginate alternative and 2-step putty–light body impression in the horizontal anteroposterior straight, horizontal anteroposterior curved, and horizontal cross-arch dimensions; between alginate and alginate alternative in the horizontal anteroposterior curved dimension; between alginate and 2-step putty–light body impression in the horizontal anteroposterior curved dimension; and between alginate alternative and digital in the vertical dimension). Polyvinyl siloxane had the highest accuracy compared to casts obtained from other impression materials and digital impressions.


2021 ◽  
Vol 11 (10) ◽  
pp. 4612
Author(s):  
KweonSoo Seo ◽  
Sunjai Kim

Purpose: The aim of this study was to present a new method to analyze the three-dimensional accuracy of complete-arch dental impressions and verify the reliability of the method. Additionally, the accuracies of conventional and intraoral digital impressions were compared using the new method. Methods: A master model was fabricated using 14 milled polyetheretherketone cylinders and a maxillary acrylic model. Each cylinder was positioned and named according to its corresponding tooth position. Twenty-five definitive stone casts were fabricated using conventional impressions of the master model. An intraoral scanner was used to scan the master model 25 times to fabricate 25 digital models. A coordinate measuring machine was used to physically probe each cylinder in the master model and definitive casts. An inspection software was used to probe cylinders of digital models. A three-dimensional part coordinate system was defined and used to compute the centroid coordinate of each cylinder. Intraclass correlation coefficient (ICC) was evaluated to examine the reliability of the new method. Independent two sample t-test was performed to compare the trueness and precision of conventional and intraoral digital impressions (α = 0.05). Results: ICC results showed that, the new method had almost perfect reliability for the measurements of the master model, conventional and digital impression. Conventional impression showed more accurate absolute trueness and precision than intraoral digital impression for most of the tooth positions (p < 0.05). Conclusions: The new method was reliable to analyze the three-dimensional deviation of complete-arch impressions. Conventional impression was still more accurate than digital intraoral impression for complete arches.


2021 ◽  
Vol 11 (2) ◽  
pp. 857
Author(s):  
Keunbada Son ◽  
Kyu-Bok Lee

The purpose of this in vitro study was to evaluate marginal and internal fits of ceramic crowns fabricated with chairside computer-aided design and manufacturing (CAD/CAM) systems. An experimental model based on ISO 12836:2015 was digitally scanned with different intraoral scanners (Omnicam (CEREC), EZIS PO (DDS), and CS3500 (Carestream)). Ceramic crowns were fabricated using the CAD/CAM process recommended by each system (CEREC, EZIS, and Carestream systems; N = 15). The 3-dimensional (3D) marginal and internal fit of each ceramic crown was measured using a 3D inspection software (Geomagic control X). Differences among the systems and various measurements were evaluated using the Kruskal–Wallis test. Statistically significant differences were validated using pairwise comparisons (α = 0.05). Occlusal gaps in the CEREC, EZIS, and Carestream groups were 113.0, 161.3, and 438.2 µm, respectively (p < 0.001). The axial gaps were 83.4, 78.0, and 107.9 µm, respectively. The marginal gaps were 77.8, 99.3, and 60.6 µm, respectively, and the whole gaps were 85.9, 107.3, and 214.0 µm, respectively. Significant differences were observed with the EZIS system compared with the other two systems in terms of the marginal gap sizes. The CEREC system showed no significant differences among the four measured regions. However, the EZIS and Carestream systems did show a statistically significant difference (p < 0.05). All three systems were judged to be capable of fabricating clinically acceptable prostheses, because the marginal gap, which is the most important factor in the marginal fit of prostheses, was recorded to be below 100 µm in all three systems.


2019 ◽  
Vol 19 (1) ◽  
Author(s):  
Francesca Cattoni ◽  
Giulia Teté ◽  
Alessandro Mauro Calloni ◽  
Fabio Manazza ◽  
Giorgio Gastaldi ◽  
...  

Abstract Background Aesthetic porcelain veneers proved to be a long-term reliable prosthetic solution, ensuring minimal invasiveness. The use of veneers requires an adhesive cementation technique, so maintaining as much enamel as possible is to ensure lasting success. A diagnostic mock-up is a key tool that allows a preview of the outcome of the aesthetic restoration: it is obtainable both in an analog and digital way. With the recent developments in impression technology and the ever so fast growing use of CAD-CAM technologies it is useful to understand the pros and cons of either one of these techniques (analog and digital) in order to identify the easier and more convenient workflow in aesthetic dentistry. Methods After taking pictures and impressions of the dental arcs of a patient in need of aesthetic rehabilitation, 52 resin models were produced and a digital drawing of the smile was outlined. Both an analog and a digital wax-up were obtained from two of the 52 models: the latter was obtained using digital impressions and a dedicated software. The analog wax-up was then used to produce 25 matrices that have later been used to mould 25 resin mock-ups using a traditional moulding protocol (Control Group - CG). The digital wax-up was used to mill 25 PMMA mock-ups. Each mock-up, both milled and moulded (total 50), was then laid on the other 50 resin models as a digital impression of it was taken. The STL. files of the milled mock-ups were compared with the 3D CAD wax-up made using a specific software. The STL. files of the analog printed mock-ups were compared with the traditional wax-up design. A statistical analysis was carried out to evaluate the difference between the groups. Results The statistical analysis showed a significant difference (P > 0.01) between the mean value of the distance between the points of the overlapping STL. meshes in GC (0.0468 mm) and in TG (Test Group - TG) (0,0109 mm). Conclusions The study showed a difference in accuracy between traditional moulded and milled mock-ups compared to their original wax-up. The data analysis reports that the digital method allows for greater accuracy. Within the limitations of this study, a fully digital workflow is to considered more reliable when it come to creating an esthetic mockup: the digital procedure has been shown to be more accurate than the one made manually which is much more operator dependent and it brings an increase to the chance of error, and that could ultimately affect the final result.


2018 ◽  
Vol 43 (4) ◽  
pp. 437-446 ◽  
Author(s):  
NG Fischer ◽  
A Tsujimoto ◽  
AG Baruth

SUMMARY Objective: Limited information is available on how to polish and finish zirconia surfaces following computer-aided design/computer-aided manufacturing (CAD/CAM), specifically, how differing application forces and reuse of zirconia polishing systems affect zirconia topography. Purpose: To determine the effect of differing, clinically relevant, polishing application forces and multiple usages of polishing burs on the surface topography of CAD/CAM zirconia. Methods: One hundred twenty 220-grit carbide finished zirconia disks were sintered according to manufacturer's directions and divided into two groups for the study of two coarse polishing bur types. Each group was divided into subgroups for polishing (15,000 rpm) at 15 seconds for 1.0 N, 4.5 N, or 11 N of force using a purpose-built fixture. Subgroups were further divided to study the effects of polishing for the first, fifth, 15th, and 30th bur use, simulating clinical procedures. Unpolished surfaces served as a control group. Surfaces were imaged with noncontact optical profilometry (OP) and atomic force microscopy (AFM) to measure average roughness values (Ra). Polishing burs were optically examined for wear. Scanning electron microscopy (SEM) was performed on burs and zirconia surfaces. One-way ANOVA with post hoc Tukey HSD (honest significant difference) tests (α=0.05) were used for statistical analyses. Results: AFM and OP Ra values of all polished surfaces were significantly lower than those of the unpolished control. Different polishing forces and bur reuse showed no significant differences in AFM Ra. However, significant differences in OP Ra were found due to differing application forces and bur reuse between the first and subsequent uses. SEM and optical micrographs revealed notable bur wear, increasing with increasing reuse. SEM and AFM micrographs clearly showed polished, periodic zirconia surfaces. Nanoscale topography, as analyzed with kurtosis and average groove depth, was found dependent on the specific polishing bur type. Conclusions: These in vitro results suggest changes in OP Ra due to bur reuse and polishing application force. Within the parameters of this study, the resultant topography of zirconia polishing is force-dependent and the reuse of coarse polishing burs is possible without statistically significant differences in Ra values after initial use. Nanoscale and microscale topography were shown to depend on specific polishing bur type.


2021 ◽  
Vol 9 (D) ◽  
pp. 37-42
Author(s):  
Abd El Azeem Mostafa ◽  
Cherif A. Mohsen

BACKGROUND: Ceramic laminate veneer restoring is considered a challenging modality in solving various esthetic dental problems. AIM: The purpose of this study was to investigate the effect of digital internal relief space on the color of ceramic laminate veneer. MATERIALS AND METHODS: An acrylic central incisor model was prepared for ceramic laminate veneer with standard measures. The prepared acrylic resin dentotype model was scanned with intraoral computer-aided design/computer-aided manufacturing (CAD/CAM) optical scanner (CEREC Omnicam|Dentsply Sirona). The laminate veneer design was planned on the optically scanned preparation on CAD/CAM system software (CEREC software|Dentsply Sirona). Thirty ceramic laminate veneer specimens were machined from zirconia-reinforced lithium silicate (Celtra Duo blocks, Dentsply/Sirona) according to standard design by CAD/CAM system with the change of the digital internal relief space settings. The specimens were divided into three groups according to their digital internal relief settings (IRS) (20, 60, and 100 μm) (n = 10). Thirty epoxy dies were duplicated from the prepared acrylic model. The ceramic laminate veneer specimens were cemented to epoxy dies with total etch resin cement system according to the manufacture instructions. The color change (ΔE) of the cemented ceramic laminate veneer specimens was measured by spectrophotometer (Vita Easy shade, Ivoclar Vivadent AG, Schaan, Liechtenstein) using the CIELAB scale and L*, a*, b*. Each specimen was measured two times (before and after cementation). The value of color difference (ΔE) was calculated according to the formula: ΔE = [(L*2 - L*1)2 + (a*2 - a*1)2 + (b*2- b*1) 2]½. RESULTS: The highest mean value of ΔE was recorded in G100 group (1.91 ± 0.33), followed by G60 group (1.83 ± 0.09), with the least value recorded in G20 group (1.49 ± 0.49). Analysis of variance test revealed a statistically significant difference between groups (p = 0.024). CONCLUSION: The change of the digital IRS affects the color of ceramic laminate veneers.


Sign in / Sign up

Export Citation Format

Share Document