scholarly journals Could Microparticles Be the Universal Quality Indicator for Platelet Viability and Function?

2016 ◽  
Vol 2016 ◽  
pp. 1-11 ◽  
Author(s):  
Elisabeth Maurer-Spurej ◽  
Kate Chipperfield

High quality means good fitness for the intended use. Research activity regarding quality measures for platelet transfusions has focused on platelet storage and platelet storage lesion. Thus, platelet quality is judged from the manufacturer’s point of view and regulated to ensure consistency and stability of the manufacturing process. Assuming that fresh product is always superior to aged product, maintaining in vitro characteristics should preserve high quality. However, despite the highest in vitro quality standards, platelets often fail in vivo. This suggests we may need different quality measures to predict platelet performance after transfusion. Adding to this complexity, platelets are used clinically for very different purposes: platelets need to circulate when given as prophylaxis to cancer patients and to stop bleeding when given to surgery or trauma patients. In addition, the emerging application of platelet-rich plasma injections exploits the immunological functions of platelets. Requirements for quality of platelets intended to prevent bleeding, stop bleeding, or promote wound healing are potentially very different. Can a single measurable characteristic describe platelet quality for all uses? Here we present microparticle measurement in platelet samples, and its potential to become the universal quality characteristic for platelet production, storage, viability, function, and compatibility.

Blood ◽  
2020 ◽  
Vol 136 (Supplement 1) ◽  
pp. 39-39
Author(s):  
Jeffrey Miles ◽  
Chomkan Usaneerungrueng ◽  
Ava M. Obenaus ◽  
Molly Y Mollica ◽  
Jake R Flynn ◽  
...  

Background: Platelets (PLTs) are currently stored at 22°C (RT, room temperature) for clinical purposes. This approach ensures long circulation time but has numerous downsides, including limited storage time due to the risk of bacterial growth and increased costs due to bacterial testing or pathogen reduction processing. PLTs stored at 4°C were the standard of care in the 1960s and 1970s. In our previous study with healthy volunteers, we showed that humans who received cold-stored PLTs have a significantly weaker response to collagen (an agonist that acts predominantly via GPVI) compared to RT-stored PLTs. If and how cold-stored PLTs recover their function in vivo is poorly understood. Methods: We obtained human PLTs by an apheresis collection and sampled either at baseline (fresh) or after five days at RT or 4°C. To test the response to GPVI-dependent agonists, we stimulated platelet-rich plasma or washed PLTs with collagen and the GPVI-specific agonist convulxin (CVX) and tested for activated integrin and α-degranulation by flow cytometry. Platelet aggregation, in response to GPVI-dependent agonists, was tested by aggregometry. We checked for GPVI expression levels by flow cytometry and for signaling events downstream of GPVI by immunoblotting. To allow for recovery of function in vitro, we incubated either 4°C-stored, or RT-stored PLTs with fresh, platelet-depleted blood for 15min, and perfused the reconstituted whole blood through a microfluidic block and post device to quantify the contractile forces of platelet aggregates. Additionally, we performed platelet force measurements at the single cell level using a traction force microscopy approach. To validate a murine model of platelet storage and transfusion, we replicated functional studies in vitro by testing mouse PLTs for integrin activation and α-degranulation by flow cytometry. Platelet aggregation in response to collagen, CVX, and the GPVI-specific antibody JAQ-1 with crosslinking anti-IgG was also tested. To evaluate the platelet function after transfusion, we obtained whole blood from UbiC-GFP mice and isolated platelet-rich plasma followed by storage for 24 hours at either 4°C or RT. To allow tracking of stored PLTs in vivo, we transfused the UbiC-GFP PLTs into wild-type C57BL/6J mice and tested for integrin activation of endogenous and transfused PLTs. Results: In human PLTs, we found a significantly increased integrin response in 4°C-stored PLTs stimulated with collagen in flow cytometry studies in vitro. Similarly, the aggregation response of 4°C-stored PLTs to collagen was significantly increased compared to RT-stored PLTs in vitro. In line with these findings, we observed more PLCγ2 phosphorylation and Syk phosphorylation at baseline in 4°C-stored PLTs compared to RT-stored PLTs, suggesting more pre-activation downstream of GPVI. However, no differences in PLCγ2 phosphorylation or Syk-phosphorylation were found between RT and 4°C-stored PLTs after stimulation with CVX, and no significant differences in surface expression levels of GPVI were detected between RT and 4°C. Stored platelets in plasma showed superior function after 4°C-storage in aggregation and flow cytometry assays. In contrast, we found similar contractile forces of platelet aggregates when RT-stored or 4°C-stored PLTs were added to platelet-depleted fresh blood. Additionally, at the single cell level, we found a similar magnitude of platelet forces in RT-stored and 4°C-stored PLTs. Similar to human PLTs, mouse PLTs showed significantly more integrin activation, P-selectin exposure, and aggregation in 4°C-stored PLTs compared to RT. To test the recovery of function of stored mouse platelets in vivo, we transfused GFP-positive PLTs into GFP-negative wild-type mice. Contrary to our pre-transfusion results, we found a significantly lower integrin activation response to CVX in 4°C-stored platelets after transfusion, consistent with our previous results in healthy human volunteers. Summary: The in vivo recovery of function of stored PLTs is an underappreciated phenomenon in platelet storage biology, and most studies are solely based on functional in vitro data. Based on our post-transfusion results, storage temperature affects the ability to recover function in vivo significantly in human and mouse platelets. Whether these differences lead to differences in clinical outcomes needs to be investigated in clinical trials. Disclosures Sniadecki: Stasys Medical Corporation: Current equity holder in private company, Other: Co-founder; Curi Bio: Current equity holder in publicly-traded company, Membership on an entity's Board of Directors or advisory committees.


1973 ◽  
Vol 29 (02) ◽  
pp. 490-498 ◽  
Author(s):  
Hiroh Yamazaki ◽  
Itsuro Kobayashi ◽  
Tadahiro Sano ◽  
Takio Shimamoto

SummaryThe authors previously reported a transient decrease in adhesive platelet count and an enhancement of blood coagulability after administration of a small amount of adrenaline (0.1-1 µg per Kg, i. v.) in man and rabbit. In such circumstances, the sensitivity of platelets to aggregation induced by ADP was studied by an optical density method. Five minutes after i. v. injection of 1 µg per Kg of adrenaline in 10 rabbits, intensity of platelet aggregation increased to 115.1 ± 4.9% (mean ± S. E.) by 10∼5 molar, 121.8 ± 7.8% by 3 × 10-6 molar and 129.4 ± 12.8% of the value before the injection by 10”6 molar ADP. The difference was statistically significant (P<0.01-0.05). The above change was not observed in each group of rabbits injected with saline, 1 µg per Kg of 1-noradrenaline or 0.1 and 10 µg per Kg of adrenaline. Also, it was prevented by oral administration of 10 mg per Kg of phenoxybenzamine or propranolol or aspirin or pyridinolcarbamate 3 hours before the challenge. On the other hand, the enhancement of ADP-induced platelet aggregation was not observed in vitro, when 10-5 or 3 × 10-6 molar and 129.4 ± 12.8% of the value before 10∼6 molar ADP was added to citrated platelet rich plasma (CPRP) of rabbit after incubation at 37°C for 30 second with 0.01, 0.1, 1, 10 or 100 µg per ml of adrenaline or noradrenaline. These results suggest an important interaction between endothelial surface and platelets in connection with the enhancement of ADP-induced platelet aggregation by adrenaline in vivo.


1974 ◽  
Vol 32 (02/03) ◽  
pp. 405-416 ◽  
Author(s):  
M. R Hardeman ◽  
Carina J L. Heynens

SummaryStorage experiments were performed at 4°, 25° and 37° C with platelet-rich plasma under sterile conditions. In some experiments also the effect of storing platelets at 4° C in whole blood was investigated.Before, during and after three days of storage, the platelets were tested at 37° C for their serotonin uptake and response to hypotonic shock. In addition some glycolytic intermediates were determined.A fair correlation was noticed between the serotonin uptake and hypotonic shock experiments. Both parameters were best maintained at 25° C. Also platelet counting, performed after the storage period, indicated 25° C as the best storage temperature. Determination of glycolytic intermediates did not justify any conclusion regarding the optimal storage temperature. Of the various anticoagulants studied, ACD and heparin gave the best results as to the serotonin uptake and hypotonic shock response, either with fresh or stored platelets. The use of EDTA resulted in the lowest activity, especially after storage.The results of these storage experiments in vitro, correspond well with those in vivo reported in the literature.


1980 ◽  
Vol 44 (02) ◽  
pp. 081-086 ◽  
Author(s):  
C V Prowse ◽  
A E Williams

SummaryThe thrombogenic effects of selected factor IX concentrates were evaluated in two rabbit models; the Wessler stasis model and a novel non-stasis model. Concentrates active in either the NAPTT or TGt50 in vitro tests of potential thrombogenicity, or both, caused thrombus formation in the Wessler technique and activation of the coagulation system in the non-stasis model. A concentrate with low activity in both in vitro tests did not have thrombogenic effects in vivo, at the chosen dose. Results in the non-stasis model suggested that the thrombogenic effects of factor IX concentrates may occur by at least two mechanisms. A concentrate prepared from platelet-rich plasma and a pyrogenic concentrate were also tested and found to have no thrombogenic effect in vivo.These studies justify the use of the NAPTT and TGt50 in vitro tests for the screening of factor IX concentrates prior to clinical use.


1973 ◽  
Vol 30 (02) ◽  
pp. 315-326
Author(s):  
J. Heinz Joist ◽  
Jean-Pierre Cazenave ◽  
J. Fraser Mustard

SummarySodium pentobarbital (SPB) and three other barbituric acid derivatives were found to inhibit platelet function in vitro. SPB had no effect on the primary response to ADP of platelets in platelet-rich plasma (PRP) or washed platelets but inhibited secondary aggregation induced by ADP in human PRP. The drug inhibited both phases of aggregation induced by epinephrine. SPB suppressed aggregation and the release reaction induced by collagen or low concentrations of thrombin, and platelet adherence to collagen-coated glass tubes. The inhibition by SPB of platelet aggregation was readily reversible and isotopically labeled SPB did not become firmly bound to platelets. No inhibitory effect on platelet aggregation induced by ADP, collagen, or thrombin could be detected in PRP obtained from rabbits after induction of SPB-anesthesia.


1997 ◽  
Vol 77 (02) ◽  
pp. 376-382 ◽  
Author(s):  
Bruce Lages ◽  
Harvey J Weiss

SummaryThe possible involvement of secreted platelet substances in agonist- induced [Ca2+]i increases was investigated by comparing these increases in aspirin-treated, fura-2-loaded normal platelets and platelets from patients with storage pool deficiencies (SPD). In the presence and absence of extracellular calcium, the [Ca2+]i response induced by 10 µM ADP, but not those induced by 0.1 unit/ml thrombin, 3.3 µM U46619, or 20 µM serotonin, was significantly greater in SPD platelets than in normal platelets, and was increased to the greatest extent in SPD patients with Hermansky-Pudlak syndrome (HPS), in whom the dense granule deficiencies are the most severe. Pre-incubation of SPD-HPS and normal platelets with 0.005-5 µM ADP produced a dose-dependent inhibition of the [Ca2+]i response induced by 10 µ M ADP, but did not alter the [Ca2+]i increases induced by thrombin or U46619. Within a limited range of ADP concentrations, the dose-inhibition curve of the [Ca2+]i response to 10 µM ADP was significantly shifted to the right in SPD-HPS platelets, indicating that pre-incubation with greater amounts of ADP were required to achieve the same extent of inhibition as in normal platelets. These results are consistent with a hypothesis that the smaller ADP-induced [Ca2+]i increases seen in normal platelets may result from prior interactions of dense granule ADP, released via leakage or low levels of activation, with membrane ADP receptors, causing receptor desensitization. Addition of apyrase to platelet-rich plasma prior to fura-2 loading increased the ADP-induced [Ca2+]i response in both normal and SPD-HPS platelets, suggesting that some release of ADP derived from both dense granule and non-granular sources occurs during in vitro fura-2 loading and platelet washing procedures. However, this [Ca2+]i response was also greater in SPD-HPS platelets when blood was collected with minimal manipulation directly into anticoagulant containing apyrase, raising the possibility that release of dense granule ADP resulting in receptor desensitization may also occur in vivo. Thus, in addition to enhancing platelet activation, dense granule ADP could also act to limit the ADP-mediated reactivity of platelets exposed in vivo to low levels of stimulation.


2019 ◽  
Vol 14 (6) ◽  
pp. 504-518 ◽  
Author(s):  
Dilcele Silva Moreira Dziedzic ◽  
Bassam Felipe Mogharbel ◽  
Priscila Elias Ferreira ◽  
Ana Carolina Irioda ◽  
Katherine Athayde Teixeira de Carvalho

This systematic review evaluated the transplantation of cells derived from adipose tissue for applications in dentistry. SCOPUS, PUBMED and LILACS databases were searched for in vitro studies and pre-clinical animal model studies using the keywords “ADIPOSE”, “CELLS”, and “PERIODONTAL”, with the Boolean operator “AND”. A total of 160 titles and abstracts were identified, and 29 publications met the inclusion criteria, 14 in vitro and 15 in vivo studies. In vitro studies demonstrated that adipose- derived cells stimulate neovascularization, have osteogenic and odontogenic potential; besides adhesion, proliferation and differentiation on probable cell carriers. Preclinical studies described improvement of bone and periodontal healing with the association of adipose-derived cells and the carrier materials tested: Platelet Rich Plasma, Fibrin, Collagen and Synthetic polymer. There is evidence from the current in vitro and in vivo data indicating that adipose-derived cells may contribute to bone and periodontal regeneration. The small quantity of studies and the large variation on study designs, from animal models, cell sources and defect morphology, did not favor a meta-analysis. Additional studies need to be conducted to investigate the regeneration variability and the mechanisms of cell participation in the processes. An overview of animal models, cell sources, and scaffolds, as well as new perspectives are provided for future bone and periodontal regeneration study designs.


Author(s):  
Cristina Tassorelli ◽  
Vincenzo Silani ◽  
Alessandro Padovani ◽  
Paolo Barone ◽  
Paolo Calabresi ◽  
...  

Abstract Background The coronavirus disease 2019 (COVID-19) pandemic has severely impacted the Italian healthcare system, underscoring a dramatic shortage of specialized doctors in many disciplines. The situation affected the activity of the residents in neurology, who were also offered the possibility of being formally hired before their training completion. Aims (1) To showcase examples of clinical and research activity of residents in neurology during the COVID-19 pandemic in Italy and (2) to illustrate the point of view of Italian residents in neurology about the possibility of being hired before the completion of their residency program. Results Real-life reports from several areas in Lombardia—one of the Italian regions more affected by COVID-19—show that residents in neurology gave an outstanding demonstration of generosity, collaboration, reliability, and adaptation to the changing environment, while continuing their clinical training and research activities. A very small minority of the residents participated in the dedicated selections for being hired before completion of their training program. The large majority of them prioritized their training over the option of earlier employment. Conclusions Italian residents in neurology generously contributed to the healthcare management of the COVID-19 pandemic in many ways, while remaining determined to pursue their training. Neurology is a rapidly evolving clinical field due to continuous diagnostic and therapeutic progress. Stakeholders need to listen to the strong message conveyed by our residents in neurology and endeavor to provide them with the most adequate training, to ensure high quality of care and excellence in research in the future.


Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4554
Author(s):  
Ralph-Alexandru Erdelyi ◽  
Virgil-Florin Duma ◽  
Cosmin Sinescu ◽  
George Mihai Dobre ◽  
Adrian Bradu ◽  
...  

The most common imaging technique for dental diagnoses and treatment monitoring is X-ray imaging, which evolved from the first intraoral radiographs to high-quality three-dimensional (3D) Cone Beam Computed Tomography (CBCT). Other imaging techniques have shown potential, such as Optical Coherence Tomography (OCT). We have recently reported on the boundaries of these two types of techniques, regarding. the dental fields where each one is more appropriate or where they should be both used. The aim of the present study is to explore the unique capabilities of the OCT technique to optimize X-ray units imaging (i.e., in terms of image resolution, radiation dose, or contrast). Two types of commercially available and widely used X-ray units are considered. To adjust their parameters, a protocol is developed to employ OCT images of dental conditions that are documented on high (i.e., less than 10 μm) resolution OCT images (both B-scans/cross sections and 3D reconstructions) but are hardly identified on the 200 to 75 μm resolution panoramic or CBCT radiographs. The optimized calibration of the X-ray unit includes choosing appropriate values for the anode voltage and current intensity of the X-ray tube, as well as the patient’s positioning, in order to reach the highest possible X-rays resolution at a radiation dose that is safe for the patient. The optimization protocol is developed in vitro on OCT images of extracted teeth and is further applied in vivo for each type of dental investigation. Optimized radiographic results are compared with un-optimized previously performed radiographs. Also, we show that OCT can permit a rigorous comparison between two (types of) X-ray units. In conclusion, high-quality dental images are possible using low radiation doses if an optimized protocol, developed using OCT, is applied for each type of dental investigation. Also, there are situations when the X-ray technology has drawbacks for dental diagnosis or treatment assessment. In such situations, OCT proves capable to provide qualitative images.


2006 ◽  
Vol 95 (03) ◽  
pp. 434-440 ◽  
Author(s):  
Satu Hyytiäinen ◽  
Ulla Wartiovaara-Kautto ◽  
Veli-Matti Ulander ◽  
Risto Kaaja ◽  
Markku Heikinheimo ◽  
...  

SummaryThrombin regulation in newborns remains incompletely understood.We studied tissue factor-initiated thrombin formation in cord plasma in vitro, and the effects of Factor VLeiden (FVL) heterozygosity on thrombin regulation both in vitro and in vivo in newborns. Pregnant women with known thrombophilia (n=27) were enrolled in the study. Cord blood and venous blood at the age of 14 days were collected from 11 FVL heterozygous newborns (FVL-positive) and from 16 FVL-negative newborns. Prothrombin fragment F1+2 and coagulation factors were measured. Tissue factor-initiated thrombin formation was studied in cord platelet-poor plasma (PPP) of FVL-negative and -positive newborns, and in both PPP and platelet-rich plasma (PRP) of healthy controls. The endogenous thrombin potential (ETP) in cord PPP or PRP was ∼60% of that in adult plasma, while thrombin formation started ∼55% and ∼40% earlier in cord PPP and PRP, respectively. Further, in FVL-positive newborns thrombin formation started significantly earlier than in FVL-negative newborns. Exogenous activated protein C (APC) decreased ETP significantly more in cord than in adult PRP. In FVL-negative cord plasma 5nM APC decreased ETP by 17.4±3.5% (mean±SEM) compared with only 3.5±3.8% in FVL-positive cord plasma (p=0.01). FVL-positive newborns showed similar levels of F1+2 but significantly decreased levels of factor V compared with FVL negative newborns both in cord plasma (FV 0.82±0.07 U/ml vs. 0.98±0.05 U/ml, p=0.03) and at the age of two weeks (FV 1.15±0.04 U/ml vs. 1.32±0.05 U/ml, p=0.03). In conclusion, newborn plasma showed more rapid thrombin formation and enhanced sensitivity to APC compared with adult plasma. FVL conveyed APC resistance and a procoagulant effect in newborn plasma. Lack of elevated F1+2 levels in FVL-positive infants, however, suggested the existence of balancing mechanisms; one could be the observed lower level of factor V in FVL heterozygous newborns.


Sign in / Sign up

Export Citation Format

Share Document