scholarly journals Bonding of Metal Orthodontic Attachments to Sandblasted Porcelain and Zirconia Surfaces

2016 ◽  
Vol 2016 ◽  
pp. 1-6 ◽  
Author(s):  
Amitoj S. Mehta ◽  
Carla A. Evans ◽  
Grace Viana ◽  
Ana Bedran-Russo ◽  
Maria Therese S. Galang-Boquiren

This study evaluates tensile bond strength (TBS) of metal orthodontic attachments to sandblasted feldspathic porcelain and zirconia with various bonding protocols. Thirty-six (36) feldspathic and 36 zirconia disc samples were prepared, glazed, embedded in acrylic blocks and sandblasted, and divided into three groups according to one or more of the following treatments: hydrofluoric acid 4% (HF), Porcelain Conditioner silane primer, Reliance Assure® primer, Reliance Assure plus® primer, and Z Prime™ plus zirconia primer. A round traction hook was bonded to each sample. Static tensile bond strength tests were performed in a universal testing machine and adhesive remnant index (ARI) scoring was done using a digital camera. One-way ANOVA and Pearson chi-square tests were used to analyze TBS (MPa) and ARI scores. No statistically significant mean differences were found in TBS among the different bonding protocols for feldspathic and zirconia,pvalues = 0.369 and 0.944, respectively. No statistically significant distribution of ARI scores was found among the levels of feldspathic,pvalue = 0.569. However, statistically significant distribution of ARI scores was found among the levels of zirconia,pvalue = 0.026. The study concluded that silanization following sandblasting resulted in tensile bond strengths comparable to other bonding protocols for feldspathic and zirconia surface.

2009 ◽  
Vol 03 (03) ◽  
pp. 173-177 ◽  
Author(s):  
Ahmet Yalcin Gungor ◽  
Hakan Turkkahraman ◽  
Necdet Adanir ◽  
Huseyin Alkis

ABSTRACTObjectives: To evaluate the effects fluorosis and self etching primers (SEP) on shear bond strengths (SBS) of orthodontic brackets.Methods: A total of 48 (24 fluorosed and 24 non-fluorosed) non-carious freshly extracted human permanent premolar teeth were used in this study. Fluorosed teeth were selected according to the modified Thylstrup and Fejerskov index (TFI), which is based on the clinical changes in fluorosed teeth. Fluorosed and non-fluorosed teeth were randomly assigned to 4 groups of 12 each. In groups I (non-fluorosed teeth) and II (fluorosed teeth), standard etching protocol was used and brackets were bonded with Light Bond. In groups III (non-fluorosed teeth) and IV (fluorosed teeth), Transbond Plus SEP was used and brackets were bonded with Transbond XT Light Cure Adhesive. All specimens were cured with a halogen light. After bonding, SBS of the brackets were tested with Universal testing machine. After debonding, all teeth and brackets in the test groups were examined under 10x magnifications. Any adhesive remained after debonding was assessed and scored according to the modified Adhesive Remnant Index (ARI).Results: ANOVA indicated a significant difference between groups (P<.001). SBS in group II (Light Bond+Fluorosis) were significantly lower than other groups. ARI scores of the groups were also significantly different (P<.001). There was a greater frequency of ARI scores of 1,2 and 3 in group II (Light Bond+Fluorosis).Conclusions: When standard etching protocol was used enamel fluorosis significantly decreased the bond strength of orthodontic brackets. Satisfactory bond strengths were obtained when SEP was used for bonding brackets to the fluorosed teeth. (Eur J Dent 2009;3:173-177)


2019 ◽  
Vol 13 (01) ◽  
pp. 075-081 ◽  
Author(s):  
Tool Sriamporn ◽  
Ploypim Kraisintu ◽  
Lily Pachanin See ◽  
Somporn Swasdison ◽  
Awiruth Klaisiri ◽  
...  

Abstract Objective The aim of this study was to evaluate the effect of neutralizing agents on the shear bond strength of hydrofluoric (HF)–etched porcelain in nonaging and aging conditions. Subjects and Methods One hundred and twenty feldspathic porcelain specimens were prepared and divided into six groups to undergo different surface conditioning methods—group 1: control; group 2: HF; group 3: HF + calcium hydroxide; group 4: HF + calcium carbonate; group 5: HF + calcium gluconate; and group 6: HF + ultrasonic. All samples were immersed in 37°C distilled water for 24 h. Half of the samples were thermocycled in water for 5,000 cycles. The shear bond strength test was performed using a universal testing machine at a crosshead speed of 0.5 mm/min. Data were statistically analyzed by two-way ANOVA and Tukey's multiple comparison test at a 95% confidence level. The surface micromorphology and surface elements were analyzed using scanning electron microscope (SEM) and energy-dispersive X-ray spectroscopy (EDX), respectively. Results The shear bond strengths of groups 2–6 were significantly higher than the control group in both aging and nonaging conditions (p < 0.05). There were no significant differences among all of the HF-etched porcelain groups (p > 0.05). SEM images of groups 2–6 illustrated similar patterns of irregularity on the specimen surfaces. Elemental analysis of EDX demonstrated identical elements on surfaces of specimens of groups 2–6. Conclusion Within the limitations of this study, shear bond strength values between HF-etched porcelain, HF-etching followed by application of neutralizing agents, and HF-etching followed by ultrasonic cleaning were not significantly different in both nonaging and aging conditions.


2009 ◽  
Vol 79 (3) ◽  
pp. 571-576 ◽  
Author(s):  
Buncha Samruajbenjakul ◽  
Boonlert Kukiattrakoon

Abstract Objective: To test the hypothesis that the there is no difference between the shear bond strengths of different base designs of ceramic brackets bonded to glazed feldspathic porcelains. Materials and Methods: Forty glazed feldspathic porcelain specimens (15 mm in diameter and 1.5 mm in thickness) were prepared and divided into 4 groups (n = 10). Ten pieces of each group of different ceramic bracket base designs (beads, large round pits, and irregular base) and one group of stainless steel brackets (served as a control) were bonded to glazed feldspathic porcelains under a 200 gram load. Then all samples were subjected to shear bond strength evaluation with a universal testing machine at a crosshead speed of 0.2 mm/min. Data were analyzed through one-way ANOVA and Tukey's HSD test at a .05 significance level. The mode of failure after debonding was examined under a stereoscope. Results: This study revealed that the beads base design had the greatest shear bond strength (24.7 ± 1.9 MPa) and was significantly different from the large round pits base (21.3 ± 2 MPa), irregular base (19.2 ± 2.0 MPa), and metal mesh base (15.2 ± 2.4 MPa). The beads base design had 100% porcelain-adhesive failure, the large round pits had 100% bracket-adhesive failure, and the irregular base design had 70% combination failure and 30% porcelain-adhesive failure. Conclusions: The hypothesis is rejected. The various base designs of metal and ceramic brackets influence bond strength to glazed feldspathic porcelain, but all should be clinically acceptable.


2011 ◽  
Vol 492 ◽  
pp. 18-23
Author(s):  
Xin Yi Zhao ◽  
Shi Bao Li ◽  
Xu Gong

To evaluate the effects of specimen grips on the measurement of the micro-tensile bond strength (mTBS) to dentin. Methods: Twelve extracted human molars were sectioned to expose mid-coronal dentin. Each surface was ground with 600-grit SiC paper. Four adhesives: Prime & Bond NT (Dentsply, USA), Contex (DMG, German), Adper Prompt (3M/ESPE, USA) and Clearfil S3Bond (Kuraray, Japan) were applied to the polished surfaces followed by creation of composite buildups. After 24 hr storage in 37°C water, the teeth were sectioned perpendicular to the adhesive interface to produce multiple beams of composite-bonded dentin, approximately 0.8 mm2in cross-sectioned area. Half of the specimens were attached to testing grips A which did not contain positioning pins and another half were attached to the testing grips B which contained positioning pins. All specimens were tested using a universal testing machine at a crosshead speed of 1.0 mm/min. Results: Specimens tested using the grips A presented lower mTBS than using the grips B (P<0.01). Many specimens tested using the grips A showed mix failure or cohesive failure within composite, and most of the failures were adhesive for specimens tested using the grips A. Conclusion: Specimen grips without positioning pins cannot accurately present mTBS and the grips with positioning pins can more accurately present mTBS.


2009 ◽  
Vol 79 (3) ◽  
pp. 564-570 ◽  
Author(s):  
Toshiya Endo ◽  
Rieko Ozoe ◽  
Koichi Shinkai ◽  
Makiko Aoyagi ◽  
Hiroomi Kurokawa ◽  
...  

Abstract Objective: To ascertain the effects of repeated bonding on the shear bond strength of orthodontic brackets bonded with a fluoride-releasing and -recharging adhesive system with a self-etching primer in comparison with two other types of adhesive system. Materials and Methods: A total of 48 premolars were collected and divided equally into three groups of 16. Each group was assigned one of three adhesive systems: Transbond XT, Transbond Plus, or a fluoride-releasing and -recharging adhesive system, Beauty Ortho Bond. Shear bond strength was measured 24 hours after bracket bonding, with the bonding/debonding procedures repeated twice after the first debonding. A universal testing machine was used to determine shear bond strengths, and bracket/adhesive failure modes were evaluated with the adhesive remnant index after each debonding. Results: At every debonding sequence, all of these three adhesive systems had a shear bond strength of 6 MPa, which is a minimum requirement for clinical use. Transbond XT and Transbond Plus had significantly higher mean shear bond strengths than did Beauty Ortho Bond at each debonding. No significant differences in mean bond strength were observed between the three debondings in each adhesive system. Bond failure at the enamel/adhesive interface occurred more frequently in Beauty Ortho Bond than in Transbond XT or Transbond Plus. Conclusions: The fluoride-releasing and -recharging adhesive system with the self-etching primer (Beauty Ortho Bond) had clinically sufficient shear bond strength in repeated bracket bonding; this finding can help orthodontists to decrease the risk of damage to enamel at debonding.


2003 ◽  
Vol 27 (1) ◽  
pp. 35-39 ◽  
Author(s):  
Silvia Pithan ◽  
Ricardo de Sousa Vieira ◽  
Marcelo Carvalho Chain

The aim of this study was to measure in vitro; the tensile bond strength of three intracanal posts used in anterior primary teeth. A total of 45 single rooted primary anterior teeth were selected for the study and the crowns sectioned leaving 1mm above the cement-enamel junction. The roots were then assigned to three groups according the type of retention used. All roots were endodonticaly treated, a 4-mm of the canal was cleansed and a base of glass ionomer cement was put at the bottom of the prepared canal. The roots were then prepared to receive intracanal posts using a # 4137 diamond bur (KG Sorensen) used in a depth of 3-mm of the length of the canal. All the prepared roots were acid etched with a 37% phosphoric acid gel for 15 seconds, rinsed, dried and the dentin adhesive Single Bond (3M) was applied. Group I received intracanal posts and cores made of composite resin (Filtek Z 250, 3M). Group II intracanal posts were made from a 0.6mm orthodontic wire bent as a Greek letter type (gamma), fixed with the Z 250 composite resin and cores were built with the same composite. Finally Group III received intracanal retention made of a fiber glass post (Fibrekor Post, Generic/Pentron) with 1.25mm diameter, fixed with Z 250 and cores were made like the other groups. The samples were submitted to tension in a universal- testing machine (Instron, model 4444). Statistical analysis (ANOVA) reveled that there were no statistically significant differences between the groups. On the basis of the results of this in vitro study it was concluded that the type of intracanal post did not interfere with the tensile strength and the most frequent type of failure was of adhesive type, corresponding to 74% of the sample.


2013 ◽  
Vol 24 (3) ◽  
pp. 247-252 ◽  
Author(s):  
Francisca Neta Cruz Soares Sampaio ◽  
Jose Renato Ribeiro Pinto ◽  
Cecilia Pedroso Turssi ◽  
Roberta Tarkany Basting

The aim of this study was to evaluate the effect of sealer application and thermal cycling on the bond strength between tissue conditioners and acrylic resin, and to observe the type of bond failure. Two hundred eighty-eight specimens (10x16x3 mm) were made of an acrylic resin (Lucitone 500, Dentsply) using a metal muffle. Specimens were divided into four groups according to the tissue conditioner (Coe-Comfort, GC or Dentusoft, Densell) used and whether or not a sealer (Eversoft Soft Liner Sealer, Myerson) was applied. Each of the four groups was subdivided into other six subgroups (n=12) to undergo thermocycling for 45, 90, 135, 180 or 210 cycles with a dwell time of 60 s, or to be left non thermocycled (control). Tensile bond strength was measured in a universal testing machine at a crosshead speed of 5 mm/min. Sealant application had no effect on the tensile bond strength of the relined acrylic resin, regardless of the tissue conditioner used (Coe-Comfort: p=0.306 and Dentusoft: p=0.1501). The number of thermal cycles had a significant effect on the tensile bond strength of the relined acrylic resin (Coe-Comfort: p=0.002 and Dentusoft: p<0.001). Both tissue conditioners presented similar bond strength to acrylic resin. For both tissue conditioners, sealer coatings had no influence on bond strength, while different numbers of thermal cycles affected that mechanical property.


Author(s):  
Samara Gasperoni PERCIANO ◽  
Diego Patrik Alves CARNEIRO ◽  
Patricia Rafaela dos SANTOS ◽  
Américo Bortolazzo CORRER ◽  
Silvia Amélia Scudeler VEDOVELLO ◽  
...  

ABSTRACT Objective: The aim of this experimental in vitro study was to evaluate whether dental bleaching performed before orthodontic treatment change the shear bond strength (SBS) of monocrystalline and polycrystalline esthetic brackets. Methods: Sixty (60) bovine incisors teeth were used and randomly divided into the following six groups (n=10): SCP (without bleaching/polycrystalline brackets); SCM (without bleaching/monocrystalline brackets); 1CP (one bleaching session/polycrystalline brackets); 1CM (one bleaching session/monocrystalline brackets); 3CP (three bleaching sessions/polycrystalline brackets); and 3CM (three bleaching sessions/monocrystalline brackets). The brackets were bonded seven days after the bleaching sessions. The samples were submitted to the SBS test in a universal testing machine (Instron model 4411) at 1 mm/min crosshead speed. The two-way analysis of variance (ANOVA) and the Tukey tests were performed at a 5% level of significance. After the mechanical test, samples were evaluated to determine the adhesive remnant index (ARI). Results: The SBS values were significantly higher for the monocrystalline brackets, when compared with the polycrystalline type (p< 0.0001), and significantly higher with three bleaching sessions than without bleaching (p< 0.0436). The ARI showed predominance of failures between the bracket and resin for all the groups (score 3). Conclusion: Three dental bleaching sessions increased the SBS values. Monocrystalline brackets showed higher SBS values than the polycrystalline type.


2020 ◽  
Vol 11 (1) ◽  
pp. 45-49 ◽  
Author(s):  
Farkhondeh Raeisosadat ◽  
Rahab Ghoveizi ◽  
Solmaz Eskandarion ◽  
Elaheh Beyabanaki ◽  
Sara Tavakolizadeh

Introduction: This study aimed to investigate the effect of different surface treatments on the bond strength of resin cement to nickel-chrome (Ni-Cr) alloy. Methods: Forty disk-shaped specimens of Ni-Cr alloy were prepared and divided into 4 groups. In the first group, the specimens’ surface was sandblasted with 50 µ Al2 O3 particles. In the second group, the specimens were prepared with the Er:YAG laser. In the third group, the specimens were prepared using the Er:YAG laser after sandblasting. In the fourth group, the specimens’ surface was covered with a thin layer of MKZ metal primer after sandblasting. Then the cylinders of composite resin were bonded to the treated metal surfaces using Panavia F2.0 resin cement. All of the samples were subjected to 2000 thermal cycles. The shear bond strength was tested using a universal testing machine at the crosshead speed of 0.5 mm/min. The failure mode was also observed by a stereomicroscope. Data were analyzed using the one-way ANOVA and the Tukey HSD test at a significance level of 0.05. Results: The shear bond strength from the highest to the lowest were as follows: the Er:YAG laser group, the sandblast and MKZ primer combination group, the sandblast group, and the sandblast and Er:YAG laser combination group. The mean differences of shear bond strength between the Er:YAG laser group and the sandblast group (P=0.047) and also between the Er:YAG laser group and the sandblast and Er:YAG laser combination group (P=0.015) were statistically significant. Conclusion: Among the different surface treatments employed in this study, Er:YAG laser treatment increased the shear bond strength between the metal alloy and the resin cement (Pavnavia F2).


2011 ◽  
Vol 82 (1) ◽  
pp. 158-164 ◽  
Author(s):  
Maria Francesca Sfondrini ◽  
Esmeralda Xheka ◽  
Andrea Scribante ◽  
Paola Gandini ◽  
Giuseppe Sfondrini

Abstract Objective: To test the null hypothesis that there is no significant difference in the shear bond strength (SBS) and Adhesive Remnant Index (ARI) scores of new vs reconditioned self-ligating brackets. Materials and Methods: One hundred and twenty permanent extracted bovine teeth were embedded in resin blocks. Three different new and reconditioned self-ligating orthodontic brackets (Smart Clip [3M Unitek]; Quick [Forestadent]; and Damon3MX [Ormco]) were tested. Scanning electron microphotographs of the different new (groups 1, 3, and 5) and reconditioned (groups 2, 4, and 6) bracket bases were taken before starting the experiments. Brackets were then bonded to the teeth using an orthodontic adhesive and were then tested in shear mode using an Instron Universal Testing Machine. ARI scores were then recorded. Statistical analysis was performed to determine significant differences in SBS and ARI Scores. Results: Smart Clip and Damon3MX reconditioned brackets showed significantly lower SBS than did new ones. On the contrary, Quick reconditioned brackets showed significantly higher SBS than did new ones. No significant differences in ARI scores were found after the reconditioning process for the three different brackets tested. Conclusion: The in-office reconditioning procedure alters the SBS of self-ligating brackets, although SBS values still remain clinically acceptable.


Sign in / Sign up

Export Citation Format

Share Document