scholarly journals Agreement between Gonioscopic Examination and Swept Source Fourier Domain Anterior Segment Optical Coherence Tomography Imaging

2016 ◽  
Vol 2016 ◽  
pp. 1-8 ◽  
Author(s):  
Mohammed Rigi ◽  
Nicholas P. Bell ◽  
David A. Lee ◽  
Laura A. Baker ◽  
Alice Z. Chuang ◽  
...  

Purpose. To evaluate interobserver, intervisit, and interinstrument agreements for gonioscopy and Fourier domain anterior segment optical coherence tomography (FD ASOCT) for classifying open and narrow angle eyes. Methods. Eighty-six eyes with open or narrow anterior chamber angles were included. The superior angle was classified open or narrow by 2 of 5 glaucoma specialists using gonioscopy and imaged by FD ASOCT in the dark. The superior angle of each FD ASOCT image was graded as open or narrow by 2 masked readers. The same procedures were repeated within 6 months. Kappas for interobserver and intervisit agreements for each instrument and interinstrument agreements were calculated. Results. The mean age was 50.9 (±18.4) years. Interobserver agreements were moderate to good for both gonioscopy (0.57 and 0.69) and FD ASOCT (0.58 and 0.75). Intervisit agreements were moderate to excellent for both gonioscopy (0.53 to 0.86) and FD ASOCT (0.57 and 0.85). Interinstrument agreements were fair to good (0.34 to 0.63), with FD ASOCT classifying more angles as narrow than gonioscopy. Conclusions. Both gonioscopy and FD ASOCT examiners were internally consistent with similar interobserver and intervisit agreements for angle classification. Agreement between instruments was fair to good, with FD ASOCT classifying more angles as narrow than gonioscopy.

2016 ◽  
Vol 95 (5) ◽  
pp. 537-541 ◽  
Author(s):  
Anastasia V. Pilat ◽  
Viral Sheth ◽  
Ravi Purohit ◽  
Frank A. Proudlock ◽  
Samira Anwar ◽  
...  

Ophthalmology ◽  
2013 ◽  
Vol 120 (12) ◽  
pp. 2403-2412 ◽  
Author(s):  
Otman Sandali ◽  
Mohamed El Sanharawi ◽  
Cyril Temstet ◽  
Taous Hamiche ◽  
Alice Galan ◽  
...  

2019 ◽  
Author(s):  
Man Hu ◽  
Qian Zheng ◽  
Zhangliang Li ◽  
Pingjun Chang ◽  
Yun-e Zhao

Abstract Background To assess the changes of anterior chamber angle in patients with shallow anterior chamber and normal anterior chamber after phacoemulsification and intraocular lens implantation (IOL) using anterior segment swept-source optical coherence tomography (AS-SS-OCT). Methods This was a prospective case control study; 60 eyes of 60 patients who underwent cataract surgery. Based on anterior chamber depth (ACD) and gonioscopy findings, the eyes were classified into two groups, shallow anterior chamber group (30 eyes) and normal anterior chamber group (30 eyes). AS-SS-OCT was used to measure ACD and angle parameters angle opening distance (AOD), angle recess area (ARA), trabecular iris space area(TISA), and trabecular iris angle (TIA). Serial changes in each group were measured before and 3 months after phacoemulsification and IOL, and the differences between the two groups were compared. Results All angle parameters including ACD, AOD, ARA, TISA, and TIA in both groups at 3 months after cataract surgery were significantly different from the preoperative values (p<0.01). In addition, we found significant differences of all angle parameters between groups of shallow anterior chamber (SAC) and normal anterior chamber (NAC) (All P< 0.05). Besides, the TISA750 in superior quadrant and anterior chamber volume (ACV) were significantly smaller in the group of SAC than those in the group of NAC (P = 0.041 and 0.002, respectively). Conclusions The parameters of anterior chamber increased significantly in both two groups but not increase to the same extent 3 months after phacoemulsification. Iris thickening may also be one of the narrow angle factors,not just age-related lens thickening.


Sign in / Sign up

Export Citation Format

Share Document