scholarly journals Complications Associated with the Use of Supraglottic Airway Devices in Perioperative Medicine

2015 ◽  
Vol 2015 ◽  
pp. 1-13 ◽  
Author(s):  
Pavel Michalek ◽  
William Donaldson ◽  
Eliska Vobrubova ◽  
Marek Hakl

Supraglottic airway devices are routinely used for airway maintenance in elective surgical procedures where aspiration is not a significant risk and also as rescue devices in difficult airway management. Some devices now have features mitigating risk of aspiration, such as drain tubes or compartments to manage regurgitated content. Despite this, the use of these device may be associated with various complications including aspiration. This review highlights the types and incidence of these complications. They include regurgitation and aspiration of gastric contents, compression of vascular structures, trauma, and nerve injury. The incidence of such complications is quite low, but as some carry with them a significant degree of morbidity the need to follow manufacturers’ advice is underlined. The incidence of gastric content aspiration associated with the devices is estimated to be as low as 0.02% with perioperative regurgitation being significantly higher but underreported. Other serious, but extremely rare, complications include pharyngeal rupture, pneumomediastinum, mediastinitis, or arytenoid dislocation. Mild short-lasting adverse effects of the devices have significantly higher incidence than serious complications and involve postoperative sore throat, dysphagia, pain on swallowing, or hoarseness. Devices may have deleterious effect on cervical mucosa or vasculature depending on their cuff volume and pressure.

2015 ◽  
Vol 2015 ◽  
pp. 1-6 ◽  
Author(s):  
Sanli Mukadder ◽  
Begec Zekine ◽  
Kayhan Gulay Erdogan ◽  
Ozgul Ulku ◽  
Ucar Muharrem ◽  
...  

We compared proseal, supreme, and i-gel supraglottic airway devices in terms of oropharyngeal leak pressures and airway morbidities in gynecological laparoscopic surgeries. One hundred and five patients undergoing elective surgery were subjected to general anesthesia after which they were randomly distributed into three groups. Although the oropharyngeal leak pressure was lower in the i-gel group initially (mean ± standard deviation; 23.9 ± 2.4, 24.9 ± 2.9, and 20.9 ± 3.5, resp.), it was higher than the proseal group and supreme group at 30 min of surgery after the trendelenburg position (25.0 ± 2.3, 25.0 ± 1.9, and 28.3 ± 2.3, resp.) and at the 60 min of surgery (24.2 ± 2.1, 24.8 ± 2.2, and 29.5 ± 1.1, resp.). The time to apply the supraglottic airway devices was shorter in the i-gel group (12.2 (1.2), 12.9 (1.0), and 6.7 (1.2), resp.,P=0.001). There was no difference between the groups in terms of their fiber optic imaging levels. pH was measured at the anterior and posterior surfaces of the pharyngeal region after the supraglottic airway devices were removed; the lowest pH values were 5 in all groups. We concluded that initial oropharyngeal leak pressures obtained by i-gel were lower than proseal and supreme, but increased oropharyngeal leak pressures over time, ease of placement, and lower airway morbidity are favorable for i-gel.


Sign in / Sign up

Export Citation Format

Share Document