scholarly journals Study on Impeller Fracture Model Based on Vibration Characteristics and Fractal Theory

2015 ◽  
Vol 2015 ◽  
pp. 1-9
Author(s):  
Xiaolong Zhang ◽  
Ruishan Yuan ◽  
Yonghui Xie

During the operation of centrifugal compressor, failure easily occurs in the presence of complicated external forces. The failure process characterizes with strong nonlinearity, and hence it is difficult to be described by conventional methods. In this paper, firstly, the cracks in different positions are described using crack fractal theory. The basic failure modes of the impeller are summarized. Secondly, a three-dimensional finite element model of the impeller is constructed. Then the von Mises stress under the centrifugal force is calculated, and the corresponding impeller failure process is simulated by “element life and death technology” in ANSYS. Finally, the impeller failure mechanism is analyzed. It can be found that the static stress is not the main cause of the impeller failure, and the dynamic characteristics of the impeller are not perfect because of the pitch vibration modes which appeared in the investigated frequency range. Meanwhile, the natural frequency of the impeller also cannot avoid the frequency of the excitation force.

2014 ◽  
Vol 607 ◽  
pp. 713-716
Author(s):  
Wen Liang Tang ◽  
Chun Yue Huang ◽  
Tian Ming Li ◽  
Ying Liang ◽  
Guo Ji Xiong ◽  
...  

In this paper, ANSYS-LSDYNA simulation software is used to build the three-dimensional finite element model of the ball bond and to get the Von Mises stress. The change of stress about the bump is researched which base on the model in different bonding pressure, bonding power and bonding time. The result show that: The stress increase with bonding pressure increase within a certain bonding pressure range, and then the stress will maintain a table number, however, the stress will continue to increase when the bonding pressure reach a certain value; increasing the bonding power, the area of lager stress will grow; prolonging the bonding time, the stress of the pad will increase with time, but when time increase to a certain value, the stress of the pad will not increase over time.


2013 ◽  
Vol 405-408 ◽  
pp. 1139-1143
Author(s):  
Wei Su ◽  
Ying Sun ◽  
Shi Qing Huang ◽  
Ren Huai Liu

Using ANSYS parametric design language, a three-dimensional finite element model is developed to analyze the stress distribution and the strength of the mega columns for XRL West Kowloon Terminus. The detailed von Mises stress distribution in each column, vertical stiffener plates and the diaphragm plates is obtained. From the analysis, the phenomenon of stress concentration is obvious in both upper and lower diaphragm plates. The local value of von Mises stress in them is higher than the yield stress value, which must be avoided by more detailed local structural design.


2012 ◽  
Vol 197 ◽  
pp. 93-97 ◽  
Author(s):  
Wen Zhi Zhao ◽  
Hong Jiang ◽  
Sheng Wei He ◽  
Lu Zhang ◽  
Xue Gang Sun

A three-dimensional finite element model is developed to simulate the integrated system which consists of the fractured bone (femur), bone plate and stabilization screw by using the ANSYS software. The stress and strain distribution of the integrated system is investigated. The numerical model simulates a patient’s imperfect walking under the assumption that the fractured bone is not able to support any load and all body weight was burden by bone plate in fractured bone section. The simulation results reveal that the maximum Von Mises stress on bone plate is much less than yield strength and fatigue strength of Titanium alloy.


Author(s):  
Yuan-Jian Yang ◽  
Liang Yang ◽  
Hai-Kun Wang ◽  
Shun-Peng Zhu ◽  
Hong-Zhong Huang

AbstractTurbine blades are one of the key components in a typical turbofan engine, which plays an important role in flight safety. In this paper, we establish a establishes a three-dimensional finite element model of the turbine blades, then analyses the strength of the blade in complicated conditions under the joint function of temperature load, centrifugal load, and aerodynamic load. Furthermore, contact analysis of blade tenon and dovetail slot is also carried out to study the stress based on the contact elements. Finally, the Von Mises stress-strain distributions are obtained to acquire the several dangerous points and maximum Von Mises stress, which provide the basis for life prediction of turbine blade.


2020 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Yihua Dou ◽  
Yufei Li ◽  
Yinping Cao ◽  
Yang Yu ◽  
Jiantao Zhang ◽  
...  

PurposeTo maintain the well integrity, the strength and sealing ability of premium connection should be in the safe scope. ISO 13679 is widely used for evaluating the ability of tubing and casing connection all over the world. FE is adopted to simulate the ISO 13679 tests.Design/methodology/approachBecause of the disadvantage of experiment such as long period, high cost and high requirement on the facility, considering the convenience and universality of finite element method, as well as the contacting nonlinearity and material nonlinearity, three-dimensional finite element model of a certain type of premium connection is established with the consideration of helix angle. The loads exerted on the premium connection are the loads in series B test and thermal cycle test of ISO 13679. The distributions of Von Mises stress and contact pressure in various cases were studied.FindingsThe results showed that the bending load has a great influence on the distribution of Von Mises stress and contact pressure for premium connection. The Von Mises stress and contact pressures on the sealing surface are smaller on the tension side and greater on the compression side. With increasing axial compression load, the contact pressures on the tension side are too small, which may lead to sealing failure. The influence of temperature on the performance of premium connection cannot be ignored when choosing or designing premium connections. Both the Von Mises stress and contact pressure decrease slightly during a period of thermal cycle. Although the performance of the premium connection is good in a period of thermal cycle, its performance in a long period should be evaluated. Finite element simulation can effectively simulate the ISO 13679 test procedure and obtain the stress and contact pressure distribution. It can be used as a reference for evaluating the performance of premium connections.Originality/valueConsidering the convenience and universality of finite element method, as well as the contacting nonlinearity and material nonlinearity, three-dimensional finite element model of a certain type of premium connection is established with the consideration of helix angle.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Niksa Mohammadi Bagheri ◽  
Mahmoud Kadkhodaei ◽  
Shiva Pirhadi ◽  
Peiman Mosaddegh

AbstractThe implementation of intracorneal ring segments (ICRS) is one of the successfully applied refractive operations for the treatment of keratoconus (kc) progression. The different selection of ICRS types along with the surgical implementation techniques can significantly affect surgical outcomes. Thus, this study aimed to investigate the influence of ICRS implementation techniques and design on the postoperative biomechanical state and keratometry results. The clinical data of three patients with different stages and patterns of keratoconus were assessed to develop a three-dimensional (3D) patient-specific finite-element model (FEM) of the keratoconic cornea. For each patient, the exact surgery procedure definitions were interpreted in the step-by-step FEM. Then, seven surgical scenarios, including different ICRS designs (complete and incomplete segment), with two surgical implementation methods (tunnel incision and lamellar pocket cut), were simulated. The pre- and postoperative predicted results of FEM were validated with the corresponding clinical data. For the pre- and postoperative results, the average error of 0.4% and 3.7% for the mean keratometry value ($$\text {K}_{\text{mean}}$$ K mean ) were predicted. Furthermore, the difference in induced flattening effects was negligible for three ICRS types (KeraRing segment with arc-length of 355, 320, and two separate 160) of equal thickness. In contrast, the single and double progressive thickness of KeraRing 160 caused a significantly lower flattening effect compared to the same type with constant thickness. The observations indicated that the greater the segment thickness and arc-length, the lower the induced mean keratometry values. While the application of the tunnel incision method resulted in a lower $$\text {K}_{\text{mean}}$$ K mean value for moderate and advanced KC, the induced maximum Von Mises stress on the postoperative cornea exceeded the induced maximum stress on the cornea more than two to five times compared to the pocket incision and the preoperative state of the cornea. In particular, an asymmetric regional Von Mises stress on the corneal surface was generated with a progressive ICRS thickness. These findings could be an early biomechanical sign for a later corneal instability and ICRS migration. The developed methodology provided a platform to personalize ICRS refractive surgery with regard to the patient’s keratoconus stage in order to facilitate the efficiency and biomechanical stability of the surgery.


2013 ◽  
Vol 845 ◽  
pp. 403-407
Author(s):  
Natesan Dhandapani ◽  
A. Gnanavelbabu ◽  
M. Sivasankar

In this changing global scenario, modification, transplantation, and replacement can be the eternal solution for most of the problems in the medical field. Hence replacement technique finds a very prominent place in medicine as a remedy having closely tied up with biomechanics. One of the most important joints in the human body is the hip joint, the big and complex joint. Many researches were conducted and many are in progress, but most of these works use simplified models with either 2D or 3D approaches. The hip joint is formed by four components like femoral head cortical bone, stem, and neck. In this system we can find orthotropic and isotropic materials working together. The main objective of this research is to develop a three dimensional surface and solid finite element model of the hip joint to predict stresses in its individual components. This model is a geometric non-linear model, which helps us understand its structural mechanical behavior, seeming to suggest with advanced research in the future new hip joint prosthesis, as well as to prove the prosthesis joint interaction before being implanted in the patient. This research explains a complete human hip joint model without cartilaginous tissue, using ANSYS 10.0 Multiphysics Analysis for nine different postures in hip joint using three different materials (CoCr, Ti6Al4V, and UHMWPE) to calculate fatigue life. The result obtained from the analysis of surface model and solid model serve to help in predicting the life cycle, surface characteristics, shear stress in XY plane, stress concentration and areas that are prone to failure. Von Mises stress on the surface of our model facilitates us to equip and design an optimized prosthesis device having unique materials composition , with a highly bio-compatible and durable alloy at a low cost could be produced. In this way, a first important step towards the structural characterization of human hip joint has been developed.


1999 ◽  
Author(s):  
Raghu N. Natarajan

Abstract Fatigue due to cyclic stresses is one of the predominant failure modes seen in retrieved tibial polyethylene components. There is no clear understanding of the influence of knee kinematics on wear seen in retrieved samples. Magnitude, direction and location of the contact load at the tibial surface were taken from the measurement obtained from gait analysis of a patient with a total knee replacement and was input into a three dimensional finite element model of a tibial component. The analyses showed that stress fluctuations and stress reversals occur both on the surface and just below the surface in the posterior region of the component. Residual stresses were produced due to plastic deformation in the posterior contact region of the component.


2020 ◽  
Vol 28 (6) ◽  
pp. 603-613 ◽  
Author(s):  
Efe Can Sivrikaya ◽  
Mehmet Sami Guler ◽  
Muhammed Latif Bekci

BACKGROUND: Zirconia has become a popular biomaterial in dental implant systems because of its biocompatible and aesthetic properties. However, this material is more fragile than titanium so its use is limited. OBJECTIVES: The aim of this study was to compare the stresses on morse taper implant systems under parafunctional loading in different abutment materials using three-dimensional finite element analysis (3D FEA). METHODS: Four different variations were modelled. The models were created according to abutment materials (zirconia or titanium) and loading (1000 MPa vertical or oblique on abutments). The placement of the implants (diameter, 5.0 × 15 mm) were mandibular right first molar. RESULTS: In zirconia abutment models, von Mises stress (VMS) values of implants and abutments were decreased. Maximum and minimum principal stresses and VMS values increased in oblique loading. VMS values were highest in the connection level of the conical abutments in all models. CONCLUSIONS: Using conical zirconia abutments decreases von Mises stress values in abutments and implants. However, these values may exceed the pathological limits in bruxism patients. Therefore, microfractures may be related to the level of the abutment.


2013 ◽  
Vol 24 (6) ◽  
pp. 635-641 ◽  
Author(s):  
Sandra Lucia Dantas de Moraes ◽  
Fellippo Ramos Verri ◽  
Joel Ferreira Santiago Junior ◽  
Daniel Augusto de Faria Almeida ◽  
Caroline Cantieri de Mello ◽  
...  

The purpose of this study was to assess the influence of the crown height of external hexagon implants on the displacement and distribution of stress to the implant/bone system, using the three-dimensional finite element method. The InVesalius and Rhinoceros 4.0 softwares were used to generate the bone model by computed tomography. Each model was composed of a bone block with one implant (3.75x10.0 mm) with external hexagon connections and crowns with 10 mm, 12.5 mm and 15 mm in height. A 200 N axial and a 100 N oblique (45°) load were applied. The models were solved by the NeiNastran 9.0 and Femap 10.0 softwares to obtain the results that were visualized by maps of displacement, von Mises stress (crown/implant) and maximum principal stress (bone). The crown height under axial load did not influence the stress displacement and concentration, while the oblique loading increased these factors. The highest stress was observed in the neck of the implant screw on the side opposite to the loading. This stress was also transferred to the crown/platform/bone interface. The results of this study suggest that the increase in crown height enhanced stress concentration at the implant/bone tissue and increased displacement in the bone tissue, mainly under oblique loading.


Sign in / Sign up

Export Citation Format

Share Document