scholarly journals A Comparative Evaluation of Static Frictional Resistance Using Various Methods of Ligation at Different Time Intervals: An In Vitro Study

2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Amanpreet Singh Natt ◽  
Amandeep Kaur Sekhon ◽  
Sudhir Munjal ◽  
Rohit Duggal ◽  
Anup Holla ◽  
...  

Aim. To compare and evaluate the static frictional resistance offered by the four different types of ligation methods in both dry and wet conditions and at different durations when immersed in artificial saliva.Material and Methods. Alastik Easy to Tie modules, Super Slick Mini Stix elastomeric modules, Power “O” modules, and 0.009″Stainless Steel ligatures were used to compare the static friction using maxillary canine and premolar Preadjusted Edgewise brackets with 0.022″× 0.028″slot and 0.019″× 0.025″stainless steel wires.Results. The mean frictional resistance for Alastik modules was the lowest and that of Stainless Steel ligatures was found to be highest among the four groups compared and the difference among the four groups was statistically significant (P<0.005). The mean static frictional resistance in all groups under dry conditions was lower than that under wet conditions. No statistical significant differences were found when the groups were compared at different time periods of immersion in artificial saliva.Conclusion. This study concludes that the Alastik modules showed the lowest mean static frictional forces compared to any other ligation method, though no significant difference was found for different time periods of immersion in the artificial saliva.

2019 ◽  
Vol 53 (2) ◽  
pp. 117-125
Author(s):  
Jayanti Choudhary ◽  
B Shashikumar ◽  
Anand K Patil

Aims: This study aimed to evaluate and compare the effect of tea tree oil (TTO) mouthwash and chlorhexidine (CHX) mouthwash on frictional resistance. Settings and Design: In vitro. Materials and Methods: In total, 60 extracted premolars were mounted on a custom-made acrylic fixture. These 60 premolars were randomly divided into 3 groups of 20 each, on which 0.022″ × 0.028″ slot MBT stainless steel brackets were bonded and 0.019″ × 0.025″ rectangular stainless steel wire was ligated with an elastomeric module. The 3 groups included a control group where the samples were immersed in artificial saliva and 2 experimental groups immersed in 0.2% CHX and TTO mouthwash, respectively, for 1.5 hours. Postimmersion static frictional resistance was evaluated on a universal testing machine at crosshead speed of 0.5 mm/min. Statistical Analysis Used: Tukey’s post hoc procedure. Results: This study showed a statistically significant difference in the frictional resistance between saliva and CHX groups and CHX and TTO groups ( P < .05). No statistically significant difference was observed between saliva and TTO groups ( P > .05). The frictional resistance was more in the CHX mouthwash group than in the TTO mouthwash group. Conclusions: Frictional resistance was lesser in the TTO mouthwash than in the CHX mouthwash. Based on this result, TTO mouthwash can be used instead of CHX mouthwash as an oral hygiene aid in patients with orthodontic treatments.


2016 ◽  
Vol 21 (4) ◽  
pp. 34-40 ◽  
Author(s):  
Graziane Olímpio Pereira ◽  
Carla Maria Melleiro Gimenez ◽  
Lucas Prieto ◽  
Marcos Gabriel do Lago Prieto ◽  
Roberta Tarkany Basting

ABSTRACT Objective: To evaluate stainless steel archwire static friction in active and passive self-ligating lingual and conventional brackets with second-order angulations. Methods: Two conventional lingual brackets for canines (STb light/Ormco; PSWb/Tecnident), and two self-ligating brackets, one active (In-Ovation L/GAC) and the other passive (3D/ Forestadent), were evaluated. A stainless steel archwire was used at 0°, 3° and 5° angulations. Metal ligatures, conventional elastic ligatures, and low friction elastic ligatures were also tested. A universal testing machine applied friction between brackets and wires, simulating sliding mechanics, to produce 2-mm sliding at 3 mm/minute speed. Results: Two-way analysis of variance demonstrated a significant effect of the interaction between brackets and angulations (p < 0.001). Tukey test indicated that the highest frictional resistance values were observed at 5° angulation for In-Ovation L, PSWb bracket with non conventional ligature, and STb bracket with metal ligature. As for 3D, PSWb with conventional or metal ligatures, and STb brackets with non conventional ligature, showed significantly lower static frictional resistance with 0° angulation. At 0° angulation, STb brackets with metal ties, In-Ovation L brackets and 3D brackets had the lowest frictional resistance. Conclusions: As the angulation increased from 0° to 3°, static friction resistance increased. When angulation increased from 3° to 5°, static friction resistance increased or remained the same. Self-ligating 3D and In-Ovation L brackets, as well as conventional STb brackets, seem to be the best option when sliding mechanics is used to perform lingual orthodontic treatment.


2011 ◽  
Vol 12 (2) ◽  
pp. 91-99 ◽  
Author(s):  
Avinash Kumar ◽  
Nadeem Husain

ABSTRACT Aim The purpose of this investigation was to determine the kinetic frictional resistance offered by stainless steel and Titanium bracket used in combination with rectangular stainless steel wire during in vitro translatory displacement of brackets. Materials and methods In this study. Brackets: (All brackets used had a torque of – 7° and an angulation of 0°): (1) Dynalock (Unitek) 0.018” slot, 3.3 mm bracket width, (2) Mini Uni-Twin (Unitek) 0.018” slot, 1.6 mm bracket width, (3) Ultra-Minitrim (Dentaurum) 0.022” slot 3.3 mm bracket width, (4) Titanium (Dentaurum) 0.022” slot, 3.3 mm bracket width. WIRES: (1) 0.016 × 0.022” stainless steel (Dentaurum), (2) 0.017 × 0.025’'stainless steel (Unitek), (3) 0.018 × 0.025” stainless steel (Dentaurum), elastomeric modules (Ortho Organisers), 0. 009” stainless steel ligature wires, hooks made of 0.021 × 0.025” stainless steel wires, super glue to bond the hooks to the base of the bracket, acetone to condition the bracket and wires before testing and artificial saliva. Brackets were moved along the wire by means of an Instron universal testing machine (1101) and forces were measured by a load cell. All values were recorded in Newtons and then converted into gms (1N-102 gm). 200 gm was then subtracted from these values to find out the frictional force for each archwire/bracket combination. For each archwire/ bracket combination three readings were taken under wet and dry condition and also with stainless steel ligature and elastomeric modules separately. Results The results showed that narrow brackets generated more friction than wider brackets. Frictional force was directly proportional to wire dimension. Titanium brackets generated more friction than stainless steel brackets. Archwire and bracket ligated with elastomeric module generated more friction than when ligated with stainless steel ligature wire. Frictional forces in the wet condition were greater than in the dry condition for all archwire to bracket combinations. Conclusion Frictional force was seen to be inversely proportional to bracket width, frictional force was inversely proportional to bracket width, and in the wet condition were greater than in the dry condition for all archwire to bracket combinations. Clinical significance This study of friction is its role in lessening the force actually received by a tooth from an active component such as a spring, loop or elastic. Hence greater applied force is needed to move a tooth with a bracket archwire combination demonstrating high magnitudes of friction compared with one with a low frictional value. How to cite this article Husain N, Kumar A. Frictional Resistance between Orthodontic Brackets and Archwire: An in vitro Study. J Contemp Dent Pract 2011;12(2):91-99.


2007 ◽  
Vol 21 (1) ◽  
pp. 51-57 ◽  
Author(s):  
Ana Cristina Soares Santos ◽  
André Tortamano ◽  
Sandra Regina Frazatto Naccarato ◽  
Gladys Cristina Dominguez-Rodriguez ◽  
Julio Wilson Vigorito

This in vitro study was designed to compare the forces generated by commercially available elastomeric chains and NiTi closed coil springs, and to determine their force decay pattern. Forty elastomeric chains and forty NiTi closed coil springs were divided into 4 groups according to the following manufacturers: (1) Morelli®, (2) Abzil®, (3) TP Orthodontics® and (4) American Orthodontics®. The specimens were extended to twice their original length and stored in artificial saliva at 37°C. Initial force was measured by means of an Instron universal testing machine and then at 1, 4, 7, 14, 21, and 28 days. The results revealed that the elastomeric chains delivered a mean initial force of 347 g for Morelli®, 351 g for American Orthodontics®, 402 g for Abzil®, and 404 g for TP Orthodontics®. The NiTi closed coil springs generated a mean initial force of 196 g for American Orthodontics®, 208 g for TP Orthodontics®, 216 g for Abzil®, and 223 g for Morelli®. The mean percentage of force decay observed after 28 days for the elastomeric chains was 37.4% for TP Orthodontics®, 48.1% for American Orthodontics®, 65.4% for Morelli®, and 71.6% for Abzil®. After 28 days, the NiTi closed coil springs presented a mean percentage of force decay of 22.6% for American Orthodontics®, 29.8% for Abzil®, 30.6% for Morelli®, and 45.8% for TP Orthodontics®. At the end of the study, significant differences were observed between the elastomeric chains and the NiTi closed coil springs. The results indicated that the studied NiTi closed coil springs are more adequate for dental movement than the elastomeric chains.


2017 ◽  
Vol 40 (2) ◽  
pp. 82-87 ◽  
Author(s):  
Faika Y. Abdelmegid ◽  
Fouad S. Salama ◽  
Waleed M. Al-Mutairi ◽  
Saud K. Al-Mutairi ◽  
Sultan O. Baghazal

Introduction The aim of this in vitro study was to assess and compare the effect of different intermediary bases on microleakage between tooth and a nanocomposite interface in Class II box cavities in primary teeth. Methods Standard Class II box cavities were prepared in 52 primary molars and randomly divided into 9 groups according to the intermediary base used (Multicore Flow, Fuji II LC, SDR, Smart Dentin Replacement, and Biodentine). All specimens were subjected to thermocycling and prepared for microleakage testing and evaluation. Results There was significant difference in the mean ranks of microleakage between the 9 groups, which was observed in the gingival side (p<0.0001) and the occlusal side (p<0.0001). The mean ranks microleakage was significantly higher with experimental SDR, experimental Multicore Flow, and positive control materials when compared with the other 6 groups. The microleakage mean ranks were statistically significantly lower in experimental Fuji II LC, experimental Biodentine, and all negative control groups when compared with the other 3 groups. Conclusions Microleakage is affected by the application of intermediate material. Experimental Biodentine and Fuji II LC showed the lowest microleakage while experimental SDR and experimental Multicore Flow showed the highest microleakage.


2018 ◽  
Vol 777 ◽  
pp. 577-581
Author(s):  
Wassana Wichai ◽  
Kanin Nimcharoensuk ◽  
Niwat Anuwongnukroh ◽  
Surachai Dechkunakorn ◽  
Pitchaya Roongrujimek

Introduction: The aim of this in-vitro study was to analyze the polymerization ability of 3 light-cured orthodontic adhesives by determining the degree of conversion (DC). Materials and Methods: Fourier transform infrared spectroscopy (FTIR) was used to evaluate the DC after polymerization immediately, 1 day, 7 days, and 30 days. The adhesives investigated were Transbond XT (3M Unitek, USA), Grengloo (Ormco Corp., USA), and Green Glue (Hangzhou Biomaterials, China). Twelve stainless steel brackets (n=4) were used and the adhesives were cured with Bluephase G2 (Ivoclar Vivadent, Liechtenstein). The data were analyzed by Kruskal-Wallis test for comparing materials and Friedman test for comparing the time periods. Results: The DC values were significantly different among the materials and among the time periods. The highest DC in each period was obtained for Grengloo and the lowest DC was observed for Transbond XT. Thus, there were significant differences between the DC values of Grengloo and Transbond XT in each period. Among the time periods, DC% at T1 (Immediately) and T3 of the material were significantly different. The DC values of all adhesives increased extremely from immediately following curing to 1 day and then slightly increased from 1 day to 7 days. Conclusions: Grengloo showed the highest levels of DC at all tested periods. The percentage values of DC largely increased from immediately following curing to 1 day. This concluded that monomers in orthodontic adhesives kept converting even after completion of photoactivation.


2012 ◽  
Vol 06 (02) ◽  
pp. 163-168 ◽  
Author(s):  
Gulce Subasi ◽  
Nilgun Ozturk ◽  
Inan Ozgur ◽  
Nalan Bozogullari

ABSTRACTObjectives: This in-vitro study investigated the marginal fit of two all-ceramic copings with 2 finish line designsMethods: Forty machined stainless steel molar die models with two different margin designs (chamfer and rounded shoulder) were prepared. A total of 40 standardized copings were fabricated and divided into 4 groups (n=10 for each finish line-coping material). Coping materials tested were IPS e.max Press and Zirkonzahn; luting agent was Variolink II. Marginal fit was evaluated after cementation with a stereomicroscope (Leica MZ16). Two-way analysis of variance and Tukey-HSD test were performed to assess the influence of each finish line design and ceramic type on the marginal fit of 2 all-ceramic copings (α =.05) Results: Two-way analysis of variance revealed no statistically significant differences for marginal fit relative to finish lines (P=.362) and ceramic types (P=.065)Conclusion: Within the limitations of this study, both types of all-ceramic copings demonstrated that the mean marginal fit was considered acceptable for clinical application (≤120 μm). (Eur J Dent 2012;6:163-168)


Materials ◽  
2020 ◽  
Vol 13 (14) ◽  
pp. 3205 ◽  
Author(s):  
Seen-Young Kang ◽  
Ji-Min Yu ◽  
Hyoung-Sik Kim ◽  
Jun-Seok Lee ◽  
Chan-Mi Yeon ◽  
...  

This study aims to compare the torque values for various lengths of the titanium-based orthodontic anchor screw (OAS), different anchorage methods and varying artificial bone densities after predrilling. Furthermore, the effects of these parameters on bone stability are evaluated. A total of 144 OASs were prepared with a diameter of 1.6 mm and heights of 6, 8 and 10 mm. Artificial bones were selected according to their density, corresponding to Grades 50, 40 and 30. Torque values for the automatic device and manual anchorage methods exhibited a statistically significant difference for the same-sized OAS, according to the bone density of the artificial bones (p < 0.05). However, when insertion torque was at the maximum rotations, there was no significant difference in the torque values for the Grade 30 artificial bone (p > 0.05). When the torque values of both anchorage methods were statistically compared with the mean difference for each group, the results of the manual anchorage method were significantly higher than those of the automatic device anchorage method (p < 0.05). A statistically significant difference was observed in the bone stability resulting from different OAS anchorage methods and artificial bone lengths. These findings suggest that the automatic anchorage method should be used when fixing the OAS.


2013 ◽  
Vol 70 (3) ◽  
pp. 279-283
Author(s):  
Mirjana Apostolovic ◽  
Biljana Kalicanin ◽  
Marija Igic ◽  
Olivera Trickovic-Janjic ◽  
Dusan Surdilovic ◽  
...  

Bacground/Aim. Glass ionomer cements (GIC) belong to the group of polycarboxyl cements, and one of the principal characteristics of these materials is their anticariogenic potential of fluorine release into saliva and enamel-dentin substance. The aim of this study was to examine the content of released fluorine from GIC restorations (Fuji IX, GC, Japan) of young permanent teeth in the medium of artificial saliva and similar releases in the same medium by the restorations of these teeth treated with a low concentration fluoride solution. Methods. We examined 12 premolars exctracted from orthodontic reasons. The GIC restored teeth were divided into the group treated daily with low concentration fluoride solution (334 ppm) and the control, not treated group. The samples of artificial saliva were analyzed for fluorine ion content using an ion selective electrode. Results. Our comparative analysis of the mean values using the Student?s t-test demonstrated a statistically significant difference in fluorine ion concentration in artificial saliva of fluoridated and non-fluoridated teeth with GIC fillings after 14 and 21 days (p < 0.05), while the difference detected after 7 days was with no statistical significance. Conclusion. The results of this in vitro study indicated that low-concentration fluoride solutions could serve to refluoridate GIC fillings and contribute to an increased fluorine content in saliva. The process of refluoridation of GIC fillings should be advised 2-3 weeks after the restoration, since the release of fluorine from GIC fillings diminishes in time.


Sign in / Sign up

Export Citation Format

Share Document