scholarly journals A Case of Battery Ingestion in a Pediatric Patient: What Is Its Importance?

2015 ◽  
Vol 2015 ◽  
pp. 1-3 ◽  
Author(s):  
Elie Alam ◽  
Marc Mourad ◽  
Samir Akel ◽  
Usamah Hadi

This is a case of a two-year-old boy who has been suffering from food regurgitation and frequent vomiting over the past seven months which were progressively worsening with time. He was initially diagnosed with gastroesophageal reflux disease and treated accordingly but responded only minimally. Investigations and interventional procedures including a chest X-ray showed a metallic round object in the upper esophagus consistent with a button battery which was removed via a thoracotomy after an esophagoscopy was not successful. This child would not have developed such serious complications and would not have required major surgery had the foreign body been identified and removed early on.

2021 ◽  
Vol 24 (04) ◽  
Author(s):  
Rasha Nadeem Ahmed ◽  
Bassam Khaleel Al-abbasi ◽  
Nashwan M-Al Hafidh

2005 ◽  
Vol 4 (2) ◽  
pp. 63-65
Author(s):  
Veronica Varney ◽  
◽  
Mary Warren ◽  
M Palmer ◽  
◽  
...  

A 61 year old former paramedic presented to A&E complaining of palpitations. He was found to be in atrial fibrillation, which reverted spontaneously to sinus rhythm. A chest x-ray taken at that time showed multiple pulmonary nodules consistent with metastatic malignancy (Figure 1). In the past he had been treated with amiodarone 200mg daily for 6 years following a previous diagnosis of atrial fibrillation, which had been attributed to alcoholic cardiomyopathy. He had discontinued the drug 8 months earlier, after selfdiagnosing hypotension and bradycardia. A previous chest X-ray, taken before starting amiodarone, was normal.


1992 ◽  
Vol 106 (8) ◽  
pp. 751-752 ◽  
Author(s):  
Hassan H. Ramadan ◽  
Nicolas Bu-Saba ◽  
Anis Baraka ◽  
Salman Mroueh

AbstractForeign body aspiration is a very common problem in children and toddlers and still a serious and sometimes fatal condition. We are reporting on a 2-year-old white asthmatic male who choked on a chick pea and presented with subcutaneous emphysema, and on chest X-ray with an isolated pneumomediastinum but not pneumothorax. On review of the literature an isolated pneumomediastinum without pneumothorax was rarely reported. This presented a challenge in management mainly because of the technique that we had to use in order to undergo bronchoscopy and removal of the foreign body. Apnoeic diffusion oxygenation was used initially while the foreign body was removed piecemeal, and afterwards intermittent positive pressure ventilation was used. The child did very well, and his subcutaneous emphysema and pneumomediastinum remarkably improved immediately post surgery.


2018 ◽  
Vol 159 (51) ◽  
pp. 2162-2166
Author(s):  
Dániel Hajnal ◽  
Tamás Kovács

Abstract: Introduction and aim: Rigid bronchoscopic foreign body removal is the gold standard procedure for foreign body aspiration. We have analysed our results of bronchoscopies and the accuracy of diagnosis among the paediatric population in Southeast Hungary. Method: A retrospective study of children admitted because of suspected solid foreign body aspiration between 2006 and 2017 was performed. Results: From among 220 admitted patients, 86 were suspected of solid particle aspiration. Presenting history was certain in 68.6% (n = 59/86). Sudden choking-like symptoms were present in 61/86 patients (70.9%), coughing in 81/86 patients (94.2%). Thoracic auscultation was positive in 67/86 cases (77.9%), chest X-ray in 75/86 patients (87.2%), while fluoroscopy only in 12/75 cases (16%). 92 bronchoscopies in 86 patients were performed. In 57 bronchoscopies, solid foreign body was found (66.2%) and the removal was successful in 56 cases. Thoracic auscultation was negative in patients with foreign body only in 6/57 cases (10.5%). In the same group, chest X-ray was negative in 33/57 cases (57.9%) and fluoroscopy was positive only in 12/57 patients (21.1%). Pneumonia or prolonged bronchitis was present in 4/86 patients (4.6%). Severe bronchial bleeding occurred in 2/86 cases (2.3%). Mortality was 1.2%, a child with severe co-morbidity and chronic aspiration passed away. Bronchoscopy was negative in 29/86 patients (33.7%). Complications were significantly higher in chronic cases than in the acute ones. Conclusion: Rigid bronchoscopy is indicated if solid foreign body aspiration is suspected and positive anamnesis, typical symptoms (coughing, choking) or positive chest auscultations are present. Diagnosis predominantly based on radiological finding is controversial due to the high possibility of false negative results. Early intervention within the first 24 hours is recommended to avoid complications. Orv Hetil. 2018; 159(51): 2162–2166.


2016 ◽  
Vol 2016 ◽  
pp. 1-4
Author(s):  
Mohammad Ashkan Moslehi ◽  
Mohammad Hadi Imanieh ◽  
Ali Adib

Foreign body aspiration (FBA) is a common incidence in young children. Leeches are rarely reported as FBA at any age. This study describes a 15-year-old female who presented with hemoptysis, hematemesis, coughs, melena, and anemia seven months prior to admission. Chest X-ray showed a round hyperdensity in the right lower lobe. A chest computed tomography (CT) demonstrated an area of consolidation and surrounding ground glass opacities in the right lower lobe. Hematological investigations revealed anemia. Finally, bronchoscopy was performed and a 5 cm leech was found within the rightB7-8bronchus and removed by forceps and a Dormia basket.


2015 ◽  
Vol 2015 ◽  
pp. 1-6
Author(s):  
Shadi Rezai ◽  
Stephen LoBue ◽  
Daniel Adams ◽  
Yewande Oladipo ◽  
Ramses Posso ◽  
...  

Background.Tuberculosis (TB) is a disease that affects hundreds of millions of people across the world. However, the incidence in developed countries has decreased over the past decades causing physicians to become unfamiliar with its unspecific symptoms. Pregnant individuals are especially difficult because many symptoms of active TB can mimic normal physiological changes of pregnancy. We present a case report of a 26-year-old multiparous woman, G4P3003, at 38-week gestation with a history of positive PPD who emigrated from Ghana 6 years ago. She came to the hospital with an initial complaint of suprapubic pain, pressure, and possible leakage of amniotic fluid for the past week. Patient also complained of a productive cough for the past 3 to 4 months with a decrease in vision occurring with the start of pregnancy. Visual acuity was worse than 20/200 in both eyes. Definitive diagnosis of active TB was delayed due to patient refusal of chest X-ray. Fortunately, delay in diagnosis was minimized since patient delivered within 24 hours of admission. Active TB was confirmed with intraocular dissemination. Patient had optic atrophy OS (left eye) and papillitis, choroiditis, and uveitis OD (right eye) due to TB infiltration. Fetus was asymptomatic and anti-TB therapy was started for both patients.


2018 ◽  
Vol 4 (2) ◽  
pp. 45
Author(s):  
Isnu Pradjoko ◽  
Chandra Jaya

Background: Aspiration of a tracheobronchial foreign body is a serious and fatal event. Progress in terms of prevention, first aid, and endoscopic technology, caused a decline of almost 20% of deaths from foreign body aspiration that occurred in the United States. Statistically, the percentage of foreign body aspirations based on their respective location is: 5% hypopharynx, 12% larynx-trachea, and 83% bronchus. Most cases of foreign body aspiration occur in children aged <15 years old; about 75% of foreign body aspirations occur in children aged 1-3 years. The female-to-male ratio is 1.4:1. Case: A 11-year-old boy swallowed needles while playing flashlight about 2 hours before coming to Pulmonary Emergency Room of Dr. Soetomo General Hospital. Discussion: Chest X-ray examination found a shadow of metal density projected in the right lung. Fiber optic bronchoscopy (FOB) was performed for diagnostic and therapeutic indication to see the presence of a foreign body in the airway and remove the foreign body, but failed. When the needle was extracted, the patient coughed that the needle bounces to the supramaxilla area. FOB with nasal cavity approach successfully extracted the corpus alienum. Conclusion: Corpus alienum of airway sometimes is difficult to extract. FOB with nasal cavity approach can be done to manage corpus alienum in the upper airway that moved from lower airway when FOB was performed.


2016 ◽  
Vol 21 (3) ◽  
pp. 196-198 ◽  
Author(s):  
Cihat Şarkış ◽  
Selçuk Yazıcı ◽  
Muhammet Can

Alkaline batteries have become the second most swallowed foreign bodies following coins. Most cases have an uncomplicated course, but some may lead to serious complications and even death.Here we report a 28 months old boy who had experienced discomfort, eating refusal, vomiting and slightly wheezing after falling from a sofa bed. He has been in three different county hospitals and two private hospitals due to complaints, has been examined by two pediatricians and a cranial surgeon. A cranial CT imaging, a cranial X-ray radiograph and a chest X-ray radiograph was obtained. Firstly, diagnosed as head and neck trauma, then diagnosed as acute bronchiolitis, and finally pneumonia. Hospitalized twice. Finally, a chest radiograph revealed a button battery in the esophagus. The foreign body was endoscopic removed. The child had a quick clinical impairment after removal of the battery.As a result, alkaline batteries with their increasing risk of engulfment poses very serious problems. The parents and physicians should be informed against increasing frequency of ingestion of alkaline batteries by infants and children. Also, clinicians should be careful about the risk of these batteries that they can cause pneumonia and infiltration which may make it difficult to detect the foreign body.


Author(s):  
Vivek Samor ◽  
Vijay Kumar ◽  
Deep Chand ◽  
Gaurav Gupta ◽  
Mamta . ◽  
...  

<p class="abstract"><strong>Background:</strong> Inhalation of foreign bodies can be life threatening and are common in paediatric age group with peak incidence in the age group of 1-3 years. The objectives were to study the clinical profile of foreign body (FB) inhalation and to study the complications of tracheo-bronchial foreign body and rigid bronchoscopy.</p><p class="abstract"><strong>Methods:</strong> A cross-sectional hospital based diagnostic study conducted for 1 year, done on 50 patients with FB inhalation, included consecutively in study after obtaining informed consent. Patients were assessed and interviewed for socio demographic details and examined using chest X-ray PA view, routine investigations and pre-anaesthetic evaluation. After all investigations a diagnostic bronchoscopy under general anaesthesia was performed to extract the foreign body. Data were analyzed through tables and diagrams and appropriate test of significance by Epi Info software.  </p><p class="abstract"><strong>Results:</strong> Total 50 FB inhalation cases (up to 10 years) in which 40% presented within 5 days to 2 weeks after inhalation. 92% were presents with cough and on chest examination 88% found to had decreased air entry, 72% presents with decreased movement and dull percussion on affected side. 70% of patients had abnormal chest X-ray finding. Foreign body found were groundnut (44%) followed by supari (32%) mostly in right main bronchus. We observed 10% patients with pneumonia, 4% had granuloma and 2% had bronchospasm.</p><p><strong>Conclusions:</strong> Prevention is best, but early recognition remains a critical factor in the treatment of FB inhalation in children. </p>


2017 ◽  
Vol 4 (10) ◽  
pp. 3548
Author(s):  
Tushar Goel ◽  
Sameer Bhate

Impalement thoracic injuries are rare of great importance due to severity and high chances of mortality. It is essential to prevent possible vascular injury by the object avoiding major haemorrhage. This study’s primary objective is to discuss 22-year-old male patient admitted in emergency with impaling thoracic trauma by metallic sharp object post battery blast at home. X-ray reveals linear foreign body: penetrating thorax and lung. CT Chest was done and assessment was made for further management with cardiothoracic department. Patient details were collected by patient’s IPD file. Complete detailed history, patient vitals, hemogram, ABO, ABG, CXR along with USG chest and abdomen and CECT chest was done. Post op daily chest X-ray and hemogram along with chest physiotherapy and spirometry was done. Treatment diagnosis was impaled linear foreign body penetrating thorax and lung, patient was shifted to OT, under GA sternotomy was performed. Foreign object passing just lateral to subclavian penetrating upper pole of lung was identified and under specific vision pulled out carefully through entry wound keeping in mind vascular trauma. Necrosed lung part was stapled and wedge resected, on POD 8 patient was discharged with satisfactory condition. Impalement thoracic traumas are rare and have high mortality. Selection of line of treatment is necessary. Indication of surgery under high risk is performed for further trauma. In our case sternotomy was planned and under specific vision impaled object which was passing just by subclavian penetrating through lung was removed safely and patient went home in good condition.


Sign in / Sign up

Export Citation Format

Share Document