scholarly journals Reduction of the Early Autogenous Shrinkage of High Strength Concrete

2015 ◽  
Vol 2015 ◽  
pp. 1-8 ◽  
Author(s):  
Drago Saje

The results of a laboratory investigation on the early autogenous shrinkage of high strength concrete, and the possibilities of its reduction, are presented. Such concrete demonstrates significant autogenous shrinkage, which should, however, be limited in the early stages of its development in order to prevent the occurrence of cracks and/or drop in the load-carrying capacity of concrete structures. The following possibilities for reducing autogenous shrinkage were investigated: the use of low-heat cement, a shrinkage-reducing admixture, steel fibres, premoistened polypropylene fibres, and presoaked lightweight aggregate. In the case of the use of presoaked natural lightweight aggregate, with a fraction from 2 to 4 mm, the early autogenous shrinkage of one-day-old high strength concrete decreased by about 90%, with no change to the concrete's compressive strength in comparison with that of the reference concrete.

1990 ◽  
Vol 211 ◽  
Author(s):  
Mette Glavind ◽  
Tine Aarre

AbstractThe application of high-strength concrete in practice is strongly limited by its more brittle behaviour than normal strength concrete.The present study deals with an investigation of the possibilities of increasing the fracture toughness of high-strength concrete by adding fibres. Tests are made with both normal strength concrete and high-strength concrete containing different amounts of steel and polypropylene fibres. Stress-strain curves in compression are obtained by a deformation controlled test system. The toughness is described with different toughness indexes.By using a previously proposed expression for the stress-strain curves, it is possible to make a non-linear load carrying capacity calculation for reinforced concrete beams. The results of the load carrying capacity calculation are compared with results of similar calculations made with the Danish code extrapolated to be valid for high-strength concrete.The investigation shows that the addition of especially steel fibres is effective in increasing toughness and the non-linear load carrying capacity for high-strength concrete. It is also shown that the compression strength of high-strength concrete is increased by addition of steel fibres. The results of the load carrying capacity calculation show that the Danish code cannot be extrapolated to be valid for high-strength concrete without any modifications.


2021 ◽  
Author(s):  
Anil K. Kar

Reinforced concrete is the number one medium of construction. It is important to have good quality concrete and reinforcing bar (rebar). It is equally important to have competent bond between rebar and concrete. About six decades ago ribbed rebars of high strength steel started replacing plain round bars of mild steel, the use of which had made reinforced concrete constructions durable. It was overlooked that ribbed rebars of carbon steel would be highly susceptible to corrosion at accelerated rates. That would not only make reinforced concrete constructions reach states of distress early, that could also destroy or reduce bond between ribbed rebars and concrete. The continued use of ribbed rebars of high strength carbon steel demonstrates a widespread lack of understanding of the phenomenon of bond between rebars and concrete. This lack of understanding of bond has led to the introduction of epoxy coated ribbed rebars, ribbed stainless steel bars and glass fiber reinforced and granite reinforced polymer rebars, all of which permit reinforced concrete carry static loads because of engagement between such rebars and concrete. But the load-carrying capacity of reinforced concrete elements is impaired, and such elements become vulnerable to local or even total failure during vibratory loads. The use of PSWC-BAR, characterized by its plain surface and wave-type configuration, permits the use of medium strength and high strength steel. In the absence of ribs, the rate of corrosion is greatly reduced. The use of PSWC-BARs, at no added effort or cost, in lieu of conventional ribbed bars, leads to enhancement of effective bond or engagement between such rebars and concrete, thereby leading to increased load-carrying capacity, several-fold higher life span, ductility and energy-absorbing capacity, and great reduction in life cycle cost and adverse impact of construction on the environment and the global climate. In keeping with a lack of understanding of bond between rebars and concrete, there is arbitrariness in the selection of the required level of percent elongation and ductility of rebars.


2010 ◽  
Vol 16 (3) ◽  
pp. 352-362 ◽  
Author(s):  
Zdeněk Kala ◽  
Libor Puklický ◽  
Abayomi Omishore ◽  
Marcela Karmazínová ◽  
Jindřich Melcher

The presented paper deals with the stochastic analysis of the ultimate limit states of steel‐concrete building members. The load carrying capacity of steel‐concrete columns, comprising of steel profiles encased in high strength concrete, in compression is analyzed. The first part of the paper lists assumptions for the determination of the theoretical load carrying capacity of the column. Principles of elasticity and plasticity are used to determine stresses in the concrete and steel sections. Statistical characteristics of input material and geometrical imperfections are listed. Results of the theoretical analysis are then compared with results of experimental research. Statistical characteristics of obtained results of the theoretical analysis were verified using statistical characteristics obtained from experimental research. Numerical simulation LHS and Monte Carlo methods, which take into account the influences of variability of input imperfections, were employed. The influence of the utilization of the plastic reserve in the determination of the load carrying capacity of the analysed strut is shown. The influence of the initial geometric imperfections of initial strut curvature on the load carrying capacity is also presented. Santrauka Straipsnyje pateikta plienbetonio pastatu elementu didžiausiu ribiniu būkliu stochastine analize, analizuojama plienbetonio kolonu, sudarytu iš plieniniu profiliuočiu, padengtu didelio stiprio betonu, laikomoji galia gniuždant. Pirmoje straipsnio dalyje išvardytos kolonos teorines laikomosios galios nustatymo prielaidos. Tamprumo ir plastiškumo principai taikyti itempiams betono ir plieno skerspjūviuose nustatyti. Nustatytos medžiagu ir geometriniu defektu statistines charakteristikos, teorines analizes rezultatai palyginti su eksperimentiniu tyrimu rezultatais. Teorines analizes metu gautu rezultatu statistines charakteristikos patikrintos taikant iš eksperimentiniu tyrimu gautus statistinius rodiklius. Pritaikytas skaitinis modeliavimas LHS ir Monte Karlo metodais, kurie ivertina pradiniu defektu kintamumo itaka. Parodyta plastiškumo atsargos naudojimo itaka, nustatant analizuojamojo statramsčio laikomaja galia, pateikta pradinio statramsčio išlinkio pirminiu geometriniu defektu itaka laikomajai galiai.


Author(s):  
Aizoh Kubo

Some typical examples of failure of gears made from very high strength steel are shown and its trigger and whose causes are discussed: Many of such failure are triggered by tooth side edge contact or tooth tip edge contact and meshing-in of the wear debris. The limit of validity of the traditional methods for load carrying capacity of gears exists in the fact that they are based on the theory of contact of tooth flanks that realize conjugate or almost conjugate action of gears. To be able to design reliable gears made from very high strength steel, a principle is shown that suggests a new method for tooth form modification and of longitudinal crowing modification to avoid such failure. Metallurgical problem of gear material and special heat treatment aiming high surface hardness is also discussed.


Sign in / Sign up

Export Citation Format

Share Document