scholarly journals An Update on the Safety and Efficacy of Corneal Collagen Cross-Linking in Pediatric Keratoconus

2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Hala El Rami ◽  
Elias Chelala ◽  
Ali Dirani ◽  
Ali Fadlallah ◽  
Henry Fakhoury ◽  
...  

Keratoconus is a degenerative disease that affects adolescents and young adults and presents with variable thinning and conical deformation of the corneal apex. The resultant irregular astigmatism can progress to levels that can significantly affect everyday activities and overall quality of life. Therefore, stopping the progression of the disease is an essential part in managing patients with keratoconus. Corneal collagen cross-linking is a minimally invasive procedure that stiffens the anterior corneal stroma by creating strong covalent bonds between collagen fibrils. Over the past decade, many studies have proved its safety and efficacy in halting keratoconus progression in adults. This review of the literature highlights the growing trend towards using this treatment in pediatric keratoconic patients. In children, keratoconus tends to be more severe and fast progression is often encountered requiring closer follow-up intervals. Standard cross-linking shows comparable results in children with a good safety-efficacy profile during follow-up periods of up to three years. Further research is needed to standardize and evaluate transepithelial and accelerated cross-linking protocols as these could be of tremendous help in a population where cooperation and compliance are major issues.

Author(s):  
Paraskevi G Zotta ◽  
Diamantis D Almaliotis ◽  
George D Kymionis ◽  
Vasilios F Diakonis ◽  
Kostas A Moschou ◽  
...  

ABSTRACT Purpose To determine the long-term alterations of corneal thickness, along with topographic outcomes, after corneal collagen cross-linking treatment (CXL) for keratoconus. Materials and methods In this retrospective case series, 46 patients (52 eyes), 32 males and 14 females, with progressive keratoconus were included. All eyes underwent CXL in accordance with the standard protocol (Dresden) for the treatment of their ectatic corneal disorder between January 2006 and June 2007. Pachymetric and topographic outcomes were evaluated preoperatively and at 1, 3, 6, 12, 24 and 36 months postoperatively. Results Mean follow-up was 28.08 ± 8.39 months (range, from 12 to 36 months). A statistically significant decline in corneal pachymetric values (at the thinnest location) when compared with preoperative values (467.65 ± 41.08 µm) was demonstrated at 1 (437.63 ± 50.57 µm), 3 (439.08 ± 52.27 µm), 6 (449.37 ± 52.73 µm), 12 (449.63 ± 83.53 µm) and 24 (459.97 ± 47.32 µm) months after CXL (p < 0.05, for all mentioned time intervals). Return to preoperative pachymetric values (469.52 ± 40.52 µm) was revealed 36 months post-CXL (p > 0.05). With respect to topographic (flat and steep keratometric values, keratoconus index), no statistically significant differences between preoperative and all postoperative intervals were found (p > 0.05, for all values for all time intervals). Conclusion Corneal pachymetric values reduce significantly up to 24 months after CXL treatment, while a return to preoperative values was revealed 36 months after the procedure. No significant changes’ concerning topographic outcomes was demonstrated after CXL, indicating stability of these parameters. How to cite this article Zotta PG, Almaliotis DD, Kymionis GD, Diakonis VF, Moschou KA, Karampatakis VE. Long-term Follow-up of Pachymetric and Topographic Alterations after Corneal Collagen Cross-Linking for Keratoconus. Int J Keratoco Ectatic Corneal Dis 2012;1(1):22-25.


Eye ◽  
2019 ◽  
Vol 33 (7) ◽  
pp. 1185-1186
Author(s):  
Darren Shu Jeng Ting ◽  
Jean-Pierre Danjoux ◽  
Stephen J. Morgan ◽  
Saurabh Ghosh ◽  
Oliver Baylis

2016 ◽  
Vol 2016 ◽  
pp. 1-5 ◽  
Author(s):  
Paolo Vinciguerra ◽  
Vito Romano ◽  
Pietro Rosetta ◽  
Emanuela F. Legrottaglie ◽  
Magdalena Kubrak-Kisza ◽  
...  

Purpose. To report the early outcomes of iontophoresis-assisted corneal collagen cross-linking procedure with epithelial debridement (I-SCXL).Methods. Twenty eyes of twenty patients with progressive keratoconus were included in this prospective clinical study. Best spectacle corrected visual acuity (BSCVA), sphere and cylinder refraction, corneal topography, Scheimpflug tomography, aberrometry, anterior segment optical coherence tomography (AS-OCT), and endothelial cell count were assessed at baseline and at 1, 3, and 6 months of follow-up. The parameters considered to establish keratoconus progression were always proven with differential maps as change in curvature in the cone area of at least 1 diopter obtained with an instantaneous map.Results. Functional parameters showed a significant improvement (p<0.05) of BSCVA after 3 and 6 months of follow-up. Morphological parameters indicated stabilization of the corneal ectasia during the follow-up; however, a positive trend was noted with a mean flattening of 1.73 D. Minimum pachymetry values showed thinning that remained constant after the treatment. The demarcation line was clearly visible in all patients, reaching a depth of308.2±37.74 μm. None of the patients had continuous progression of keratoconus or had to repeat cross-linking procedures. Endothelial cell counts did not change significantly (p>0.05).Conclusion. The early results indicate that the I-SCXL may be able to reduce the treatment time and improve the riboflavin diffusion.


2015 ◽  
Vol 2015 ◽  
pp. 1-8 ◽  
Author(s):  
Rafic Antonios ◽  
Ali Dirani ◽  
Ali Fadlallah ◽  
Elias Chelala ◽  
Adib Hamade ◽  
...  

Purpose. To evaluate the long-term safety and clinical outcome of phakic Visian toric implantable collamer lens (ICL) insertion after corneal collagen cross-linking (CXL) in progressive keratoconus.Methods. This was a retrospective study of 30 eyes (19 patients), with progressive keratoconus, who underwent sequential CXL followed by Visian toric ICL implantation after 6 months.Results. At baseline, 6 eyes had stage I, 14 eyes stage II, and 10 eyes stage III keratoconus graded by Amsler-Krumeich classification. At 6 months after CXL, onlyK(steep) andK(max) decreased significantly from baseline, with no change in visual acuity or refraction. Flattening in keratometric readings was stable thereafter. There was significant improvement in mean uncorrected distance visual acuity (1.57 ± 0.56 to 0.17 ± 0.06 logMAR,P<0.001) and mean corrected distance visual acuity (0.17 ± 0.08 to 0.11 ± 0.05 logMAR,P<0.001) at 12 months after ICL implantation that was maintained at the 2-year follow-up. Mean cylinder power and mean spherical equivalent (SE) also decreased significantly after ICL implantation. A small hyperopic shift in SE (+0.25 D) was observed at 2 years that did not alter visual outcomes.Conclusions. Visian toric ICL implantation following CXL is an effective option for improving visual acuity in patients with keratoconus up to 2 years.


Sign in / Sign up

Export Citation Format

Share Document