scholarly journals Determination of 16 Selected Trace Elements in Children Plasma from China Economical Developed Rural Areas Using High Resolution Magnetic Sector Inductively Coupled Mass Spectrometry

2014 ◽  
Vol 2014 ◽  
pp. 1-6 ◽  
Author(s):  
Xiaobing Liu ◽  
Jianhua Piao ◽  
Zhenwu Huang ◽  
Shuang-Qing Zhang ◽  
Weidong Li ◽  
...  

A rapid, accurate, and high performance method of high resolution sector field inductively coupled plasma mass spectrometry (HR-ICP-MS) combined with a small-size sample (0.1 mL) preparation was established. The method was validated and applied for the determination of 16 selected plasma trace elements (Fe, Cu, Zn, Rb, B, Al, Se, Sr, V, Cr, Mn, Co, As, Mo, Cd, and Pb). The linear working ranges were over three intervals, 0-1 μg/L, 0–10 μg/L and 0–100 μg/L. Correlation coefficients (R2) ranged from 0.9957 to 0.9999 and the limits of quantification (LOQ) ranged from 0.02 μg/L (Rb) to 1.89 μg/L (Se). The trueness (or recovery) spanned from 89.82% (Al) to 119.15% (Se) and precision expressed by the relative standard deviation (RSD %) for intra-day ranging from 1.1% (Zn) to 9.0% (Se), while ranged from 3.7% (Fe) to 12.7% (Al) for interday. A total of 440 plasma samples were collected from Chinese National Nutrition and Health Survey Project 2002 (CNNHS 2002), which represented the status of plasma trace elements for the children aged 3–12 years from China economical developed rural areas. The concentrations of 16 trace elements were summarized and compared by age groups and gender, which can be used as one of the basic components for the formulation of the baseline reference values of trace elements for the children in 2002.

1994 ◽  
Vol 77 (4) ◽  
pp. 1004-1023 ◽  
Author(s):  
J E Longbottom ◽  
T D Martin ◽  
K W Edgell ◽  
S E Long ◽  
M R Plantz ◽  
...  

Abstract A joint U.S. Environmental Protection Agency (U.S. EPA)—AOAC interlaboratory method validation study was conducted on U.S. EPA method 200.8, Determination of Trace Elements in Waters and Wastes by Inductively Coupled Plasma–Mass Spectrometry. The purpose of the study was to determine and compare the mean recovery and precision of the inductively coupled plasma–mass spectrometry (ICP–MS) analyses for 20 trace elements in reagent water, drinking water, and groundwater. The formal study was based on Youden’s nonreplicate plan for collaborative tests of analytical methods. The test waters were spiked with the 20 trace elements at 6 concentration levels in the 0.8–200 μg/L range, prepared as 3 Youden pairs. Thirteen collaborators spiked 100 mL aliquots of the test waters, acidified them with 1 mL concentrated HNO3 and 0.5 mL concentrated HCl, reduced the volume to 20 mL by heating in an open beaker at 85°C, refluxed them for 30 min at 95°C, and diluted them to 50 mL. After centrifuging or settling the samples, a 20 mL portion of the supernatant was diluted to 50 mL and analyzed by ICP–MS. Related experiments evaluated the method performance in wastewater and wastewater digestate at a single concentration pair, and an alternative nitric acid digestion procedure. Mean recoveries for reagent water, drinking water, and groundwater were generally 95–105% with between-laboratory relative standard deviations about 4–8%. The method also worked well with wastewaters and digestate, with between-laboratory relative standard deviations averaging 8% and recoveries averaging 100%. Recoveries of silver, however, were low in all matrixes at concentrations over 100 μg/L. The nitric acid digestion procedure was comparable in accuracy and precision to the mixed-acid digestion in U.S. EPA method 200.8. The method was adopted first action by AOAC INTERNATIONAL.


Sign in / Sign up

Export Citation Format

Share Document