scholarly journals Multisite Kinetic Modeling of13C Metabolic MR Using [1-13C]Pyruvate

2014 ◽  
Vol 2014 ◽  
pp. 1-10 ◽  
Author(s):  
Pedro A. Gómez Damián ◽  
Jonathan I. Sperl ◽  
Martin A. Janich ◽  
Oleksandr Khegai ◽  
Florian Wiesinger ◽  
...  

Hyperpolarized13C imaging allows real-timein vivomeasurements of metabolite levels. Quantification of metabolite conversion between [1-13C]pyruvate and downstream metabolites [1-13C]alanine, [1-13C]lactate, and [13C]bicarbonate can be achieved through kinetic modeling. Since pyruvate interacts dynamically and simultaneously with its downstream metabolites, the purpose of this work is the determination of parameter values through a multisite, dynamic model involving possible biochemical pathways present in MR spectroscopy. Kinetic modeling parameters were determined by fitting the multisite model to time-domain dynamic metabolite data. The results for different pyruvate doses were compared with those of different two-site models to evaluate the hypothesis that for identical data the uncertainty of a model and the signal-to-noise ratio determine the sensitivity in detecting small physiological differences in the target metabolism. In comparison to the two-site exchange models, the multisite model yielded metabolic conversion rates with smaller bias and smaller standard deviation, as demonstrated in simulations with different signal-to-noise ratio. Pyruvate dose effects observed previously were confirmed and quantified through metabolic conversion rate values. Parameter interdependency allowed an accurate quantification and can therefore be useful for monitoring metabolic activity in different tissues.

Author(s):  
David A. Grano ◽  
Kenneth H. Downing

The retrieval of high-resolution information from images of biological crystals depends, in part, on the use of the correct photographic emulsion. We have been investigating the information transfer properties of twelve emulsions with a view toward 1) characterizing the emulsions by a few, measurable quantities, and 2) identifying the “best” emulsion of those we have studied for use in any given experimental situation. Because our interests lie in the examination of crystalline specimens, we've chosen to evaluate an emulsion's signal-to-noise ratio (SNR) as a function of spatial frequency and use this as our critereon for determining the best emulsion.The signal-to-noise ratio in frequency space depends on several factors. First, the signal depends on the speed of the emulsion and its modulation transfer function (MTF). By procedures outlined in, MTF's have been found for all the emulsions tested and can be fit by an analytic expression 1/(1+(S/S0)2). Figure 1 shows the experimental data and fitted curve for an emulsion with a better than average MTF. A single parameter, the spatial frequency at which the transfer falls to 50% (S0), characterizes this curve.


2012 ◽  
Vol 108 (10) ◽  
pp. 2837-2845 ◽  
Author(s):  
Go Ashida ◽  
Kazuo Funabiki ◽  
Paula T. Kuokkanen ◽  
Richard Kempter ◽  
Catherine E. Carr

Owls use interaural time differences (ITDs) to locate a sound source. They compute ITD in a specialized neural circuit that consists of axonal delay lines from the cochlear nucleus magnocellularis (NM) and coincidence detectors in the nucleus laminaris (NL). Recent physiological recordings have shown that tonal stimuli induce oscillatory membrane potentials in NL neurons (Funabiki K, Ashida G, Konishi M. J Neurosci 31: 15245–15256, 2011). The amplitude of these oscillations varies with ITD and is strongly correlated to the firing rate. The oscillation, termed the sound analog potential, has the same frequency as the stimulus tone and is presumed to originate from phase-locked synaptic inputs from NM fibers. To investigate how these oscillatory membrane potentials are generated, we applied recently developed signal-to-noise ratio (SNR) analysis techniques (Kuokkanen PT, Wagner H, Ashida G, Carr CE, Kempter R. J Neurophysiol 104: 2274–2290, 2010) to the intracellular waveforms obtained in vivo. Our theoretical prediction of the band-limited SNRs agreed with experimental data for mid- to high-frequency (>2 kHz) NL neurons. For low-frequency (≤2 kHz) NL neurons, however, measured SNRs were lower than theoretical predictions. These results suggest that the number of independent NM fibers converging onto each NL neuron and/or the population-averaged degree of phase-locking of the NM fibers could be significantly smaller in the low-frequency NL region than estimated for higher best-frequency NL.


2013 ◽  
Vol 4 (10) ◽  
pp. 2095 ◽  
Author(s):  
Claudio Vinegoni ◽  
Sungon Lee ◽  
Paolo Fumene Feruglio ◽  
Pasquina Marzola ◽  
Matthias Nahrendorf ◽  
...  

Geophysics ◽  
1970 ◽  
Vol 35 (1) ◽  
pp. 24-32 ◽  
Author(s):  
Bibhu P. Dash ◽  
K. Ahmed Obaidullah

A seismic trace may be represented as the sum of a signal and noise series. Each of the series may further be represented by convolution of a finite wavelet and a random series. With this representation, and provided that the signal and noise are uncorrelated, it is possible, in theory, to extract signal and noise statistics from two adjacent traces of a reflection seismogram. Some experiments are shown on model seismic traces, and it is shown that within the time‐duration of the seismic wavelet, the estimates of signal and noise statistics are reasonable for low signal‐to‐noise ratio. There remains, however, the problem of determining the optimum time lengths of the estimates.


2021 ◽  
Vol 15 ◽  
Author(s):  
Thanet Pakpuwadon ◽  
Kiyotaka Sasagawa ◽  
Mark Christian Guinto ◽  
Yasumi Ohta ◽  
Makito Haruta ◽  
...  

In this study, we propose a complementary-metal-oxide-semiconductor (CMOS) image sensor with a self-resetting system demonstrating a high signal-to-noise ratio (SNR) to detect small intrinsic signals such as a hemodynamic reaction or neural activity in a mouse brain. The photodiode structure was modified from N-well/P-sub to P+/N-well/P-sub to increase the photodiode capacitance to reduce the number of self-resets required to decrease the unstable stage. Moreover, our new relay board was used for the first time. As a result, an effective SNR of over 70 dB was achieved within the same pixel size and fill factor. The unstable state was drastically reduced. Thus, we will be able to detect neural activity. With its compact size, this device has significant potential to become an intrinsic signal detector in freely moving animals. We also demonstrated in vivo imaging with image processing by removing additional noise from the self-reset operation.


1989 ◽  
Vol 35 (5) ◽  
pp. 874-878 ◽  
Author(s):  
F Moussa ◽  
L Dufour ◽  
J R Didry ◽  
P Aymard

Abstract By optimizing the conditions for determining trans-phylloquinone and its metabolite, K-2,3-epoxide, in serum through a two-step HPLC process combined with fluorometric detection after coulometric reduction, we have been able to develop a method applicable to small volumes of serum (200 to 500 microL). The limit of detection (signal-to-noise ratio of 3) was 15 ng/L for trans-phylloquinone, 30 ng/L for K-2,3-epoxide. The trans-phylloquinone concentrations measured by this method in serum from 82 children, ages one to six years, whose results were normal for overall coagulation tests, ranged from 40 to 880 ng/L (median 175 ng/L). We discuss these findings and compare them with vitamin K1(20) values reported for adults.


Author(s):  
Daniele De Marchi ◽  
Alessandra Flori ◽  
Nicola Martini ◽  
Giulio Giovannetti

Background: Cardiac magnetic resonance evaluations generally require a radiofrequency coil setup comprising a transmit whole-body coil and a receive coil. In particular, radiofrequency phased-array coils are employed to pick up the signals emitted by the nuclei with high signal-tonoise ratio and a large region of sensitivity. Methods: Literature discussed different technical issues on how to minimize interactions between array elements and how to combine data from such elements to yield optimum Signal-to-Noise Ratio images. However, image quality strongly depends upon the correct coil position over the heart and of one array coil portion with respect to the other. Results: In particular, simple errors in coil positioning could cause artifacts carrying to an inaccurate interpretation of cardiac magnetic resonance images. Conclusion: This paper describes the effect of array elements misalignment, starting from coil simulation to cardiac magnetic resonance acquisitions with a 1.5 T scanner. </P><P> Phased-array coil simulation was performed using the magnetostatic approach; moreover, phantom and in vivo experiments with a commercial 8-elements cardiac phased-array receiver coil permitted to estimate signal-to-noise ratio and B1 mapping for aligned and shifted coil.