scholarly journals Antibiogram for Haemodialysis Catheter-Related Bloodstream Infections

2014 ◽  
Vol 2014 ◽  
pp. 1-6 ◽  
Author(s):  
Abdul Halim Abdul Gafor ◽  
Pau Cheong Ping ◽  
Anis Farahanum Zainal Abidin ◽  
Muhammad Zulhilmie Saruddin ◽  
Ng Kah Yan ◽  
...  

Background. Haemodialysis (HD) catheter-related bloodstream infections (CRBSIs) are a major complication of long-term catheter use in HD. This study identified the epidemiology of HD CRBSIs and to aid in the choice of empiric antibiotics therapy given to patients with HD CRBSIs.Methods. Patients with HD CRBSIs were identified. Their blood cultures were performed according to standard sterile technique. Specimens were sent to the microbiology lab for culture and sensitivity testing. Results were tabulated in antibiograms.Results. 18 patients with a median age of 61.0 years (IQR: 51.5–73.25) were confirmed to have HD CRBSIs based on our study criteria. Eight (44.4%) patients had gram-negative infections, 7 (38.9%) patients gram-positive infections, and 3 (16.7%) patients had polymicrobial infections. We noted that most of the gram-negative bacteria were sensitive to ceftazidime. Unfortunately, cloxacillin resistance was high among gram-positive organisms.Coagulase-negative StaphylococcusandBacillussp. were the most common gram-positive organisms and they were sensitive to vancomycin.Conclusion. Our study revealed the increased incidence of gram-negative organism in HD CRBSIs. Antibiogram is an important tool in deciding empirical antibiotics for HD CRBSIs. Tailoring your antibiotics accordingly to the antibiogram can increase the chance of successful treatment and prevent the emergence of bacterial resistance.

2020 ◽  
Vol 7 (Supplement_1) ◽  
pp. S386-S386
Author(s):  
Susan M Novak-Weekley ◽  
Aye Aye Khine ◽  
Tino Alavie ◽  
Namidha Fernandez ◽  
Laxman Pandey ◽  
...  

Abstract Background Conventional antimicrobial susceptibility testing (AST) of microorganisms from positive blood cultures (PBC) can take ≥ 2 days. In order to improve the turnaround time for AST on a PBC, CLSI and EUCAST have made efforts to standardize procedures for disk diffusion (DD) direct from a PBC. Qvella Corporation (Richmond Hill, ON, Canada) has recently developed FAST-Prep, an automated centrifugal sample preparation system that rapidly delivers a Liquid Colony consisting of a purified, concentrated, viable cell suspension directly from a PBC. This study was performed to investigate the feasibility of DD AST off of a PBC using a FAST-Prep Liquid Colony. Methods Contrived PBC samples were prepared by spiking 6 species of Gram-positive and 4 species of Gram-negative bacteria (3-5 strains per species) into FA® Plus bottles and incubating in the BACT/ALERT® VIRTUO® System (bioMerieux, Durham, NC). After positivity, 3 mL of PBC was added to the FAST-Prep cartridge. After 20 minutes of processing in the FAST-Prep instrument, the Liquid Colony was removed from the cartridge and a 0.5 McFarland sample was prepared for DD AST. In parallel, the DD AST from a PBC was performed using 4 drops of PBC (CLSI direct method). Both methods were compared to conventional colony-based DD AST. After 16-18 hours of incubation zone diameters and S/I/R interpretations were determined. Categorical agreement (CA) and errors for both DD AST methods were calculated. In addition, colony plate counting was performed on 0.5 McFarland suspensions of Liquid Colony and the plate colony to determine biomass recovery and sample purity. Results CA for a FAST-Prep DD AST for Gram-positive and Gram-negative bacteria was 95.6% and 98.6%, respectively, compared to CA for CLSI DD AST of 77.2% and 81.9%, respectively. Biomass in the Liquid Colony was 7.2x108 and 1.2x109 CFU for Gram-positive and Gram-negative bacteria, respectively. Cell concentration in the 0.5 McFarland suspension of the Liquid Colony was 3.7x107 and 5.9x107 CFU/mL for Gram-positive and Gram-negative bacteria, respectively, which was similar to the concentration for the reference colony suspension. Conclusion The results support the potential role of FAST-Prep in providing a Liquid Colony for use in rapid AST. Disclosures Susan M. Novak-Weekley, PhD, D(ABMM), Qvella (Employee, Shareholder) Aye Aye Khine, PhD, Qvella (Employee, Shareholder) Tino Alavie, PhD, Qvella (Employee) Namidha Fernandez, MS, Qvella (Employee) Laxman Pandey, MS, Qvella (Employee) Abdossamad Talebpour, PhD, Qvella (Employee, Shareholder)


2019 ◽  
Vol 80 (9) ◽  
pp. 1787-1795 ◽  
Author(s):  
Shazwana Sha'arani ◽  
Siti Noor Fitriah Azizan ◽  
Fazrena Nadia Md Akhir ◽  
Muhamad Ali Muhammad Yuzir ◽  
Nor'azizi Othman ◽  
...  

Abstract Staphylococcus sp. as Gram-positive and Escherichia coli as Gram-negative are bacterial pathogens and can cause primary bloodstream infections and food poisoning. Coagulation, flocculation, and sedimentation processes could be a reliable treatment for bacterial removal because suspended, colloidal, and soluble particles can be removed. Chemical coagulants, such as alum, are commonly used. However, these chemical coagulants are not environmentally friendly. This present study evaluated the effectiveness of coagulation, flocculation, and sedimentation processes for removing Staphylococcus sp. and E. coli using diatomite with standard jar test equipment at different pH values. Staphylococcus sp. demonstrated 85.61% and 77.23% significant removal in diatomite and alum, respectively, at pH 5. At pH 7, the removal efficiency decreased to 79.41% and 64.13% for Staphylococcus sp. and E. coli, respectively. At pH 9, there was a decrease in Staphylococcus sp. after adding diatomite or alum compared with that of E. coli. The different removal efficiencies of the Gram-positive and Gram-negative bacteria could be owing to the membrane composition and different structures in the bacteria. This study indicates that diatomite has higher efficiency in removing bacteria at pH 5 and can be considered as a potential coagulant to replace alum for removing bacteria by the coagulation process.


Blood ◽  
2008 ◽  
Vol 112 (11) ◽  
pp. 4664-4664
Author(s):  
Young-Ho Lee ◽  
Yeon Jung Lim ◽  
Soon-young Song ◽  
Ji-hye Kim ◽  
Sung-hee Oh ◽  
...  

Abstract A retrospective analysis was performed on febrile neutropenic episodes in children with hematologic and oncologic diseases from 2005 to 2008. We reviewed total 255 febrile episodes occurred during the 3-year period in a total of 114 patients. Twenty-eight episodes of bacteremia occurred during neutropenic period in a total of 16 patients. All these patients had central venous catheter. There were 18 febrile episodes of Grampositive bacteria (64.3%), 9 episodes of Gram-negative bacteria (32.1%), and 1 episode of Candida (3.6%). The isolated organisms were as follows: Coagulase-negative Staphylococcus (CNS, N=17, 60.7%), Staphylococcus aureus (N=1, 3.6%), Enterobacter spp. (N=2, 7.1%), Pseudomonas spp. (N=2, 7.1%), Klebsiella (N=2, 7.1%), E. coli (N=2, 7.1%), Acinetobacter (N=1, 3.6%), Candida. (N=1, 3.6%). The bloodstream infection with CNS were more prevalent in children with Chemo-port (12 episodes in 6 from 34 patients, 17.6%) than in children with Hickman catheter (5 episodes in 5 from 22 patents, 22.7%), even though statistically not significant. In antibiotic susceptibility tests, all gram positive bacteria were resistant to penicillin and oxacillin, and sensitive to vancomycin and teicoplanin. In the case of Gram-negative bacteria, resistant rates to amikacin, gentamicin, imipenem, and piperacillin/tazobactam were 4.8%, 38.1%, 14.3%, and 42.9%, respectively. Based on this retrospective analysis, which reflects predominance of CNS bacteremia in febrile neutropenic patients, more emphasis needs to be laid on the empirical antibiotic regimen including vancomycin or teicoplanin as well as the strict skin preparations during procedures in children with central venous catheter.


2020 ◽  
Vol 10 (4) ◽  
pp. 639-654
Author(s):  
А. A. Meleshko ◽  
A. G. Afinogenova ◽  
G. E. Afinogenov ◽  
A. A. Spiridonova ◽  
V. P. Tolstoy

Metal and metal oxide nanoparticles (NPs) are promising antibacterial agents. They have a broad antimicrobial activity against both Gram-positive and Gram-negative bacteria, viruses, and protozoans. The use of NPs reduces the possibility of the microbial resistance development. This review briefly shows the general mechanisms and the main factors of antibacterial activity of NPs. In this article, a comprehensive review of the recent researches in the field of new antimicrobial agents with superior long-term bactericidal activity and low toxicity is provided. The review gives the examples of synthesis of double and triple nanocomposites based on following oxides: CuO, ZnO, Fe3O4, Ag2O, MnO2, etc. including metal and nonmetal doped nanocomposites (for example with Ag, Ce, Cr, Mn, Nd, Co, Sn, Fe, N, F, etc.). Compared with bactericidal action of individual oxides, the nanocomposites demonstrate superior antibacterial activity and have synergistic effects. For example, the antimicrobial activity of ZnO against both Gram-positive and Gram-negative bacteria was increased by -100% by formation of triple nanocomposites ZnO—MnO2—Cu2O or ZnO—Ag2O—Ag2S. Similar effect was showed for Ce-doped ZnO and Zn-doped CuO. The present article also provides the examples of nanocomposites containing NPs and organic (chitosan, cellulose, polyvinylpyrrolidone, biopolymers, etc.) or inorganic materials with special structure (graphene oxide, TiO2 nanotubes, silica) which demonstrate controlled release and longterm antibacterial activity. All of the considered nanocomposites and their combinations have a pronounced long-term antimicrobial effect including against antibiotic-resistant strains. They are able to prevent the formation of microbial biofilms on biotic and abiotic surfaces, have low toxicity to eukaryotic cells, demonstrate anti-inflammatory and woundhealing properties in compositions with polymers (sodium alginate, collagen, polyvinylpyrrolidone, etc.). The use of nanoscale systems can solve several important practical problems at the same time: saving of long-term antimicrobial activities while reducing the number of compounds, creation of new antimicrobial agents with low toxicity and reduced environmental impact, development of new biocidal materials, including new coatings for effective antimicrobial protection of medical devices.


2017 ◽  
Vol 66 (2) ◽  
pp. 171-180 ◽  
Author(s):  
Fevronia Kolonitsiou ◽  
Matthaios Papadimitriou-Olivgeris ◽  
Anastasia Spiliopoulou ◽  
Vasiliki Stamouli ◽  
Vasileios Papakostas ◽  
...  

The aim of the study was to assess the epidemiology, the incidence of multidrug-resistant bacteria and bloodstream infections’ (BSIs) seasonality in a university hospital. This retrospective study was carried out in the University General Hospital of Patras, Greece, during 2011–13 y. Blood cultures from patients with clinical presentation suggestive of bloodstream infection were performed by the BacT/ALERT System. Isolates were identified by Vitek 2 Advanced Expert System. Antibiotic susceptibility testing was performed by the disk diffusion method and E-test. Resistance genes (mecA in staphylococci; vanA/vanB/vanC in enterococci; blaKPC/blaVIM/blaNDM in Klebsiella spp.) were detected by PCR. In total, 4607 (9.7%) blood cultures were positive from 47451 sets sent to Department of Microbiology, representing 1732 BSIs. Gram-negative bacteria (52.3%) were the most commonly isolated, followed by Gram-positive (39.5%), fungi (6.6%) and anaerobes bacteria (1.8%). The highest contamination rate was observed among Gram-positive bacteria (42.3%). Among 330 CNS and 150 Staphylococcus aureus, 281 (85.2%) and 60 (40.0%) were mecA-positive, respectively. From 113 enterococci, eight were vanA, two vanB and two vanC-positives. Of the total 207 carbapenem-resistant Klebsiella pneumoniae (73.4%), 202 carried blaKPC, four blaKPC and blaVIM and one blaVIM. A significant increase in monthly BSIs’ incidence was shown (R2: 0.449), which may be attributed to a rise of Gram-positive BSIs (R2: 0.337). Gram-positive BSIs were less frequent in spring (P < 0.001), summer (P < 0.001), and autumn (P < 0.001), as compared to winter months, while Gram-negative bacteria (P < 0.001) and fungi (P < 0.001) were more frequent in summer months. BSIs due to methicillin resistant S. aureus and carbapenem-resistant Gram-negative bacteria increased during the study period. The increasing incidence of BSIs can be attributed to an increase of Gram-positive BSI incidence, even though Gram-negative bacteria remained the predominant ones. Seasonality may play a role in the predominance of Gram-negative’s BSI.


Blood ◽  
2016 ◽  
Vol 128 (22) ◽  
pp. 3703-3703
Author(s):  
Xiaofeng Luo ◽  
Jinhua Ren ◽  
Zhizhe Chen ◽  
Ting Yang ◽  
Jianda Hu

Abstract High procalcitonin (PCT) levels are strongly associated with systemic bacterial infections. PCT is produced in response to bacterial endotoxin and inflammatory cytokines. Few studies are available in the literature on PCT ability to distinguish different strains of bloodstream infections in patients with hematologic diseases. The aim of the present study was to explore the value of determining serum PCT values early, i.e., as soon as blood cultures are positive, in a large population of patients with hematologic diseases. Patients with hematologic diseases admitted to the hematology department of our hospitalfrom January 2013 to March 2016 who had bloodstream infections were retrospectively analyzed. Patients whose blood samples were collected for simultaneous blood culture and PCT test were enrolled in the study, and they were divided into agranulocytosis and non-agranulocytosis groups. Automatic microbial analyzer was used to identify all strains, and PCT levels were analyzed with an automatic electrochemiluminescence system. The relationship between PCT levels and the strains in bloodstream infections was analyzed and compared, and the diagnostic efficacy of PCT was evaluated using the receiver operating characteristic (ROC) curve. A total of 494 bloodstream infection cases that fulfilled the inclusion criteria were included in the study, involving 312 cases of bloodstream infection with single Gram-negative, 146 cases with single Gram-positive, 12 cases with single fungi, 19 cases with polymicrobes, and 5 cases identified as contaminated specimens. Unpaired t-test was used for data analysis. PCT levels for single Gram-negative infection (15.17±2.11 ng/ml) were significantly higher than those for Gram-positive infection (3.30 ± 0.93 ng/ml) (P<0.0001), or those for single fungi infection (0.22 ± 0.04 ng/ml) (P<0.0001). PCT levels for single Gram-positive infection were also significantly higher than those in single fungi infection (P<0.01). In the agranulocytosis group, which included 403 cases, the PCT levels in the single Gram-negative infection (14.14 ± 2.13 ng/ml) were significantly higher than those in single Gram-positive (2.49 ± 0.73 ng/ml) (P<0.0001), or in single fungi infection (0.24 ± 0.04 ng/ml) (P<0.0001). The PCT levels in the single Gram-positive bacterial infection were also significantly higher than those in single fungi infection (P<0.01). In the single Gram-negative bacteria bloodstream infection, we further found that the PCT levels in Enterobacteriaceae infection (17.00 ± 3.04 ng/ml) were significantly higher than those in nonfermentative Gram-negatives infection (6.49 ± 1.50 ng/ml) (P<0.01). ROC analysis was performed on monomicrobial blood cultures. ROC of single Gram-negative and Gram-positive infections revealed that the area under the curve (AUC) was 0.687, the best cut-off value was 0.58 ng/ml, the sensitivity was 60.81% and specificity was 71%. ROC of single Gram-negative and fungi infections revealed that the AUC was 0.795, the best cut-off value was 0.42 ng/ml, the sensitivity was 67% and specificity was 100%. ROC of single Gram-positive and fungi infections revealed that the AUC was 0.6, the best cut-off value was 0.44 ng/ml, the sensitivity was 37% and specificity was 100%. In the non-agranulocytosis group, we only found that the PCT levels in the single Gram-negative infection were significantly higher than those in single Gram-positive infection (P<0.05). In summary, early serum PCT quantitative determination can be used as a routine test to help to distinguish Gram-negative bacteria, Gram-positive bacteria, or fungi bloodstream infections in patients with hematologic diseases. These findings will be of great clinical value to select appropriate antibiotics for patients with hematologic diseases and bloodstream infections. Figure Figure. Disclosures No relevant conflicts of interest to declare.


2020 ◽  
Vol 8 (2) ◽  
pp. 280 ◽  
Author(s):  
Marylise Duperthuy

Growing resistance to antibiotics is one of the biggest threats to human health. One of the possibilities to overcome this resistance is to use and develop alternative molecules such as antimicrobial peptides (AMPs). However, an increasing number of studies have shown that bacterial resistance to AMPs does exist. Since AMPs are immunity molecules, it is important to ensure that their potential therapeutic use is not harmful in the long term. Recently, several studies have focused on the adaptation of Gram-negative bacteria to subinhibitory concentrations of AMPs. Such concentrations are commonly found in vivo and in the environment. It is therefore necessary to understand how bacteria detect and respond to low concentrations of AMPs. This review focuses on recent findings regarding the impact of subinhibitory concentrations of AMPs on the modulation of virulence and resistance in Gram-negative bacteria.


Drug Research ◽  
2020 ◽  
Vol 70 (10) ◽  
pp. 463-471
Author(s):  
Md Shamshir Alam ◽  
Prem Kapur ◽  
ParuKutty Pillai ◽  
Krishna Kolappa Pillai

AbstractKnowledge of the aetiological agents and its susceptibility to antimicrobial agents enables the clinician to initiate appropriate empirical antimicrobial therapy and guides diagnostic procedures. The aims of the study were to identify prevalence of bacterial pathogens causing sepsis and observe their antimicrobial resistance trends in hospitalized patients. A prospective cohort study was conducted on patients of sepsis admitted at a university hospital over a period of six months. Pathogens were identified by morphological, biochemical and serological tests as per the American Society for Microbiology. Antibacterial sensitivity of bacterial strains isolated from clinically diagnosed sepsis was carried out by Kirby-Bauer disk diffusion method and interpreted according Clinical and Laboratory Standards Institute guidelines. The data were analyzed by using Statistical Package for Social Sciences, version 16.0 (SPSS 16.0, Chicago, IL, USA). Coagulase negative Staphylococcus (63.5%) and Staphylococcus aureus (23.1%) were the most frequently isolated Gram positive bacteria. Acinetobacter species (31%) and Salmonella typhi (24.1%) were the most frequently isolated Gram negative bacteria. Coagulase negative Staphylococcus showed significant resistance to ciprofloxacin and tetracycline. Acinetobacter species showed significant resistance to ampicillin, amoxicillin and amoxiclav. Salmonella typhi showed significant resistance to ampicillin, amoxicillin, cefotaxime, netilmicin and, tetracycline. Escherichia coli showed significant resistance to ampicillin and netilmicin. All the stains of Staphylococcus aureus were resistant to amoxicillin. Coagulase negative Staphylococcus and Acinetobacter species were predominant Gram positive and Gram negative bacteria, respectively, causing sepsis. Increasing rates of bacterial resistance to commonly use antimicrobial agents were observed.


2018 ◽  
Vol 57 (2) ◽  
Author(s):  
Te-Din Huang ◽  
Ekaterina Melnik ◽  
Pierre Bogaerts ◽  
Stephanie Evrard ◽  
Youri Glupczynski

ABSTRACT Rapid identification and susceptibility testing results are of importance for the early appropriate therapy of bloodstream infections. The ePlex (GenMark Diagnostics) blood culture identification (BCID) panels are fully automated PCR-based assays designed to identify Gram-positive and Gram-negative bacteria, fungi, and bacterial resistance genes within 1.5 h from positive blood culture. Consecutive non-duplicate positive blood culture episodes were tested by the ePlex system prospectively. The choice of panel(s) (Gram-positive, Gram-negative, and/or fungal pathogens) was defined by Gram-stained microscopy of blood culture-positive bottles (BacT/Alert; bioMérieux). Results with the ePlex panels were compared to the identification results obtained by standard culture-based workflow. In total, 216 positive blood culture episodes were evaluable, yielding 263 identification results. The sensitivity/positive predictive value for detection by the ePlex panels of targeted cultured isolates were 97% and 99% for the Gram-positive panel and 99% and 96% for the Gram-negative panel, resulting in overall agreement rates of 96% and 94% for the Gram-positive and Gram-negative panel, respectively. All 26 samples with targeted resistance results were correctly detected by the ePlex panels. The ePlex panels provided highly accurate results and proved to be an excellent diagnostic tool for the rapid identification of pathogens causing bloodstream infections. The short time to results may be of added value for optimizing the clinical management of patients with sepsis.


Sign in / Sign up

Export Citation Format

Share Document