scholarly journals Fixation of a Periprosthetic Intertrochanteric Hip Fracture below a Birmingham Hip Resurfacing

2014 ◽  
Vol 2014 ◽  
pp. 1-6 ◽  
Author(s):  
J. Macdonald ◽  
A. Robinson ◽  
I. Brown

This case report involves a 56-year-old female (Mrs X) with a traumatic intertrochanteric hip fracture with subtrochanteric extension below a previous Birmingham hip resurfacing. Periprosthetic fractures following hip resurfacing are usually subcapital and treated with a revision or conservative management. We present an unusual surgical problem with an interesting solution stabilising the fracture using a proximal femoral locking compression plate (LCP). Eight months following surgery the patient is able to walk pain free and there is good fixation and stability.

2020 ◽  
Vol 10 (3) ◽  
pp. e19.00540-e19.00540
Author(s):  
Jordy van Rijn ◽  
Maarten C. Koper ◽  
Pieter K. Bos

2020 ◽  
Vol 9 (11) ◽  
pp. 3758
Author(s):  
Byung-Woo Min ◽  
Kyung-Jae Lee ◽  
Chul-Hyun Cho ◽  
In-Gyu Lee ◽  
Beom-Soo Kim

This study investigated the incidence of failure after locking compression plate (LCP) osteosynthesis around a well-fixed stem of periprosthetic femoral fractures (PFFs). We retrospectively evaluated outcomes of 63 Vancouver type B1 and C PFFs treated with LCP between May 2001 and February 2018. The mean follow-up duration was 47 months. Only patients with fracture fixation with a locking plate without supplemental allograft struts were included. We identified six periprosthetic fractures of proximal Vancouver B1 fractures with spiral pattern (Group A). Vancouver B1 fractures around the stem tip were grouped into seven transverse fracture patterns (Group B) and 38 other fracture patterns such as comminuted, oblique, or spiral (Group C). Vancouver C fractures comprised 12 periprosthetic fractures with spiral, comminuted, or oblique patterns (Group D). Fracture healing without complications was achieved in all six cases in Group A, 4/7 (57%) in Group B, 35/38 (92%) in Group C, and 11/12 (92%) in Group D, respectively. The failure rates of transverse Vancouver type B1 PFFs around the stem tip were significantly different from those of Vancouver type B1/C PFFs with other patterns. For fracture with transverse pattern around the stem tip, additional fixation is necessary because LCP osteosynthesis has high failure rates.


2013 ◽  
Vol 2013 ◽  
pp. 1-4
Author(s):  
Hiren M. Divecha ◽  
Hans A. J. Marynissen

Distal humeral periprosthetic fractures below intramedullary nail devices are complex and challenging to treat, in particular due to the osteopenic/porotic nature of bone found in these patients. Fixation is often difficult to satisfactorily achieve around the intramedullary device, whilst minimising soft tissue disruption. Descriptions of such cases in the current literature are very rare. We present the case of a midshaft humeral fracture treated with a locking compression plate that developed a nonunion, in a 60-year old female. This went on to successful union after exchange for an intramedullary humeral nail. Unfortunately, the patient developed a distal 1/5th humeral periprosthetic fracture, which was then successfully addressed with a single-contoured, extra-articular, distal humeral locking compression plate (Synthes) with unicortical locking screws and cerclage cables proximally around the distal nail tip region. An excellent postoperative range of motion was achieved.


Sign in / Sign up

Export Citation Format

Share Document