scholarly journals The Effect of Nanoparticles on Thermal Efficiency of Double Tube Heat Exchangers in Turbulent Flow

2014 ◽  
Vol 2014 ◽  
pp. 1-5 ◽  
Author(s):  
Reza Aghayari ◽  
Heydar Madah ◽  
Bahram Keyvani ◽  
Abdolreza Moghadassi ◽  
Fatemeh Ashori

This paper refers to the Overall Heat Transfer Coefficient of Nano Fluids (OHTCNF) in heat exchangers and the relevant effective parameters. An improvement in Heat Transfer (HT) and OHTCNF containing nanoaluminum oxide with ca. 20 nm particle size and particular volume fraction in the range of 0.001-0.002 has been reported. The effects of temperature and concentration of nanoparticles on HT variation as well as Overall Heat Transfer Coefficient (OHTC) in a countercurrent double tube heat exchanger with turbulent flow have been studied. The experimental results show a remarkable 8%–10% rise in the mean HT and the OHTC. Accordingly, with an increase in the processing temperature and/or particle concentration the OHTC was observed to increase.

2019 ◽  
Vol 70 (6) ◽  
pp. 2040-2043
Author(s):  
Sinziana Radulescu ◽  
Loredana Irena Negoita ◽  
Ion Onutu

A relation for calculation of the effective overall heat transfer coefficient in a triple concentric-tube heat exchanger is proposed. The relation of the effective overall heat transfer coefficient is obtained based on total thermal resistance and it is applied within a case study for thermal analysis of two triple concentric-tube heat exchangers with different geometries, hot fluids and operating conditions. Through case study it is found that the values of effective overall heat transfer coefficient can be obtained with acceptable errors, up to 3 % for both heat exchangers.


2015 ◽  
Vol 37 ◽  
pp. 199
Author(s):  
Ali Mahrooghi ◽  
Mohammad Moghiman

In this paper, forced convection flow and heat transfer of a Al2O3/Water nanofluid have beeninvestigated numerically by single and two phase (volume of fluid) models. Nanofluid flows inside the innertube of the isothermally concentric circular and sinusoidal double tube heat exchangers while hot pure waterflows in the outer tube. The single-phase and two-phase models is used to simulate the nanofluid forcedconvection of 2% and 3% volume concentrations. The renormalization group k-ε model is used to simulateturbulence in ANSYS FLUENT 15.0. Results show that the overall heat transfer coefficient increases withnanoparticle volume concentrations in the heat exchangers. The highest overall heat transfer coefficient rates aredetected, for each concentration and shape, corresponding to the highest flow rate for the sinusoidal tube heatexchanger . The maximum overall heat transfer coefficient enhancement is 220% for the particle volumeconcentration of 3% at the inner tube of concentric sinusoidal double tube heat exchanger corresponding to flowrate =10 LPM. The results reveal that the Al2O3/water pressure drop along the inner tube of circular andsinusoidal double tube heat exchanger increases by about 3% and 5% for volume concentrations of 2% and 3%,respectively, given flow rate compared to the base fluid.Comparison of these results with Rohit S. Khedkar‘spublished experimental data, showed good agreement.


2009 ◽  
Vol 62-64 ◽  
pp. 694-699 ◽  
Author(s):  
E. Akpabio ◽  
I.O. Oboh ◽  
E.O. Aluyor

Shell and tube heat exchangers in their various construction modifications are probably the most widespread and commonly used basic heat exchanger configuration in the process industries. There are many modifications of the basic configuration which can be used to solve special problems. Baffles serve two functions: Most importantly, they support the tubes in the proper position during assembly and operation and prevent vibration of the tubes caused by flow-induced eddies, and secondly, they guide the shell-side flow back and forth across the tube field, increasing the velocity and the heat transfer coefficient. The objective of this paper is to find the baffle spacing at fixed baffle cut that will give us the optimal values for the overall heat transfer coefficient. To do this Microsoft Excel 2003 package was employed. The results obtained from previous studies showed that to obtain optimal values for the overall heat transfer coefficient for the shell and tube heat exchangers a baffle cut of 20 to 25 percent of the diameter is common and the maximum spacing depends on how much support the tubes need. This was used to validate the results obtained from this study.


2015 ◽  
Vol 62 (4) ◽  
pp. 509-522 ◽  
Author(s):  
R. Dharmalingam ◽  
K.K. Sivagnanaprabhu ◽  
J. Yogaraja ◽  
S. Gunasekaran ◽  
R. Mohan

Abstract Cooling is indispensable for maintaining the desired performance and reliability over a very huge variety of products like electronic devices, computer, automobiles, high power laser system etc. Apart from the heat load amplification and heat fluxes caused by many industrial products, cooling is one of the major technical challenges encountered by the industries like manufacturing sectors, transportation, microelectronics, etc. Normally water, ethylene glycol and oil are being used as the fluid to carry away the heat in these devices. The development of nanofluid generally shows a better heat transfer characteristics than the water. This research work summarizes the experimental study of the forced convective heat transfer and flow characteristics of a nanofluid consisting of water and 1% Al2O3 (volume concentration) nanoparticle flowing in a parallel flow, counter flow and shell and tube heat exchanger under laminar flow conditions. The Al2O3 nanoparticles of about 50 nm diameter are used in this work. Three different mass flow rates have been selected and the experiments have been conducted and their results are reported. This result portrays that the overall heat transfer coefficient and dimensionless Nusselt number of nanofluid is slightly higher than that of the base liquid at same mass flow rate at same inlet temperature. From the experimental result it is clear that the overall heat transfer coefficient of the nanofluid increases with an increase in the mass flow rate. It shows that whenever mass flow rate increases, the overall heat transfer coefficient along with Nusselt number eventually increases irrespective of flow direction. It was also found that during the increase in mass flow rate LMTD value ultimately decreases irrespective of flow direction. However, shell and tube heat exchanger provides better heat transfer characteristics than parallel and counter flow heat exchanger due to multi pass flow of nanofluid. The overall heat transfer coefficient, Nusselt number and logarithmic mean temperature difference of the water and Al2O3 /water nanofluid are also studied and the results are plotted graphically.


2020 ◽  
Vol 38 (4) ◽  
pp. 845-862
Author(s):  
Saif Nawaz Ahmad ◽  
Om Prakash

Earth air tube heat exchanger (EATHE) is one of the passive technologies which utilize the earth stored heat (renewable energy) for heating/cooling the buildings. EATHE releases heat to earth for cooling space in summer, making the earth a heat sink and extracts earth-stored energy for heating space in winter and makes the earth a heat source. This paper optimizes the Length of the ground heat exchanger and overall heat transfer coefficient of earth air heat exchanger using the Taguchi technique for cooling application. For this purpose, we select six factors such as installation depth of Pipe (A), Pipe's inner diameter (B), Thermal conductivity of pipe material (C), Inlet air temperature (D), Outlet air temperature (E), Inlet air velocity (F). All these factors are taken at three levels, and we select an L27 orthogonal array for experimental runs. The ground heat exchanger's Length and the overall heat transfer coefficient were then calculated for each experimental run. In the Taguchi method, we find the signal to noise ratio for an optimal combination of all six factors and ANOVA to find the order of influencing parameters and their percentage contributions for both the objective parameters. According to our results, the best combination for all the six factors for ground heat exchanger length and overall heat transfer coefficient were A1B1C3D1E3F1 and A2B3C2D3E1F3, respectively. The highest and lowest influencing factors for ground heat exchanger length were the pipe's inner diameter and the pipe's installation depth with their contribution factors of 69.12 and 0.32%, respectively. In contrast, the highest and lowest influencing factors for the overall heat transfer coefficient were the pipe's inner diameter and thermal conductivity of pipe material with their contribution factors of 75.97and 0%, respectively. Hence the order of influence of all the six factors for both the objective parameters was BEFDCA.


Author(s):  
Paritosh Singh

Abstract: Research in convective heat transfer using suspensions of nanometer sized solid particles in a base fluid started only over the past decade. Recent investigations on nanofluids, as such suspensions are often called, indicate that the suspended nanoparticles markedly change the transport properties and heat transfer characteristics of the suspension. The very first part of the research work summarizes about the various thermo physical properties of Al2O3 Nanofluid. In evacuated tube solar water heating system nanofluids are used as primary fluid and DM water as secondary fluid in Shell and Tube Heat Exchanger. The experimental analysis of Shell and Tube heat exchanger integrated with Evacuated tube solar collector have been carried out with two types of primary fluids. Research study of shell and tube heat exchanger is focused on heat transfer enhancement by usage of nano fluids. Conventional heat transfer fluids have inherently low thermal conductivity that greatly limits the heat exchange efficiency. The result of analysis shows that average relative variation in LMTD and overall heat transfer coefficient is 24.56% and 52.0% respectively. The payback period of system is reduced by 0.4 years due to saving is in replacement cost of Evacuated Tube Collector. Keywords: ETC; Nanofluid; LMTD; Thermal Conductivity; Overall heat transfer coefficient


2017 ◽  
Vol 9 (4) ◽  
pp. 451-461
Author(s):  
Artur Rubcov ◽  
Sabina Paulauskaitė ◽  
Violeta Misevičiūtė

The paper provides the results of experimental and theoretical test of a wavy fin and tube heat exchanger used to cool air in a ventilation system when the wavy fin of the heat exchanger is dry and wet. The experimental tests, performed in the range of 1000<Re<4500 of the Reynolds number applying LMTD-LMED methodology, determined the dependency of the heat transfer coefficient on the supplied air flow rate with the varying geometry of the heat exchanger (the number of tube rows, the distance between fins, the thickness of the fin and the diameter of the tube). The experimental tests were performed on 9 heat exchangers in heating and 6 heat exchangers in cooling mode. After processing the results of the experimental tests, empirical equation defining the characteristics of the heat transfer coefficient of all heat exchangers were derived. The maximum heat transfer coefficient deviation is 11.6 percent. The correction factor of the wet fin (Lewis number) depending on the number of Reynolds, which ranges from 0.75 to 1.1 also is determined. Maximum capacity deviation equals 3.7 percent. The obtained equations can only be applied to a certain group of heat exchangers (with the same shape of fins or the distance between the tubes). The results of the experimental test and simulation with ANSYS program are compared and the heat transfer coefficients vary from 6.5 to 11.4 percent.


Author(s):  
Ataollah Khanlari ◽  
Adnan Sözen ◽  
Halil İbrahim Variyenli

PurposeThe plate heat exchangers (PHE) with small size but large efficiency are compact types of heat exchangers formed by corrugated thin pressed plates, operating at higher pressures when compared to most other traditional exchangers. This paper aims to analyze heat transfer characteristics in the PHE experimentally and numerically.Design/methodology/approachComputational fluid dynamics analysis has been used to simulate the problem by using the ANSYS fluent 16 software. Also, the effect of using TiO2/water nanofluid as working fluid was investigated. TiO2/water nanofluid had 2% (Wt/Wt) nanoparticle content. To improve solubility of the TiO2nanoparticles, Triton X-100 was added to the mixture. The results have been achieved in different working condition with changes in fluid flow rate and its temperature.FindingsThe obtained results showed that using TiO2/water nanofluid improved the overall heat transfer coefficient averagely as 6%, whereas maximum improvement in overall heat transfer coefficient was 10%. Also, theoretical and experimental results are in line with each other.Originality/valueThe most important feature which separates the present study from the literature is that nanofluid is prepared by using TiO2nanoparticles in optimum size and mixing ratio with surfactant usage to prevent sedimentation and flocculation problems. This process also prevents particle accumulation that may occur inside the PHE. The main aim of the present study is to predict heat transfer characteristics of nanofluids in a plate heat exchanger. Therefore, it will be possible to analyze thermal performance of the nanofluids without any experiment.


Author(s):  
Pablo Coronel ◽  
K.P. Sandeep

This study involved the determination of convective heat transfer coefficient in both helical and straight tubular heat exchangers under turbulent flow conditions. The experiments were conducted in helical heat exchangers, with coils of two different curvature ratios (d/D = 0.114 and 0.078), and in straight tubular heat exchangers at various flow rates (1.89 x 10-4 - 6.31 x 10-4 m3/s) and for different end-point temperatures (92 - 149 °C). The results show that the overall heat transfer coefficient (U) in the helical heat exchanger is much higher than that in straight tubular heat exchangers. In addition, U was found to be larger in the coil of larger curvature ratio (d/D = 0.114) than in the coil of smaller curvature ratio (d/D = 0.078). The inside (hi) and outside (ho) convective heat transfer coefficients were determined based on the overall heat transfer coefficient and a correlation to compute the inside convective heat transfer coefficient (hi) as a function of NRe, NPr, and d/D was developed.


Sign in / Sign up

Export Citation Format

Share Document