scholarly journals A Communication Based Islanding Detection Method for Photovoltaic Distributed Generation Systems

2014 ◽  
Vol 2014 ◽  
pp. 1-17 ◽  
Author(s):  
Gökay Bayrak ◽  
Mehmet Cebeci

PV based distributed generation (DG) systems must have some electrical connection standards while they connected to an electrical grid. One of these electrical conditions and the most important one is unplanned islanding condition. Islanding is a very dangerous condition because it could damage the PV system and related electrical systems and also working people have been at risk in islanding condition. In this application study, a new communication based islanding detection method was introduced for grid tied PV systems. A real time controller was developed with Labview for detecting islanding condition. Developed method is a hybrid method which uses the effective ways of communication based and passive methods. The results obtained from the proposed real time islanding detection method show that proposed method is reliable, robust, and independent from load and inverter. Nondetection zone (NDZ) is almost zero and islanding detection time is approximately 1-2 cycles indicated in experimental results so this time has a significant short response time according to IEEE 929-2000 standard. The proposed method is effective and presents a realistic solution to islanding so it could be implemented easily to grid tied PV systems and could be used in real system applications.

2015 ◽  
Vol 2015 ◽  
pp. 1-11 ◽  
Author(s):  
Manop Yingram ◽  
Suttichai Premrudeepreechacharn

The mainly used local islanding detection methods may be classified as active and passive methods. Passive methods do not perturb the system but they have larger nondetection zones, whereas active methods have smaller nondetection zones but they perturb the system. In this paper, a new hybrid method is proposed to solve this problem. An over/undervoltage (passive method) has been used to initiate an undervoltage shift (active method), which changes the undervoltage shift of inverter, when the passive method cannot have a clear discrimination between islanding and other events in the system. Simulation results on MATLAB/SIMULINK show that over/undervoltage and undervoltage shifts of hybrid islanding detection method are very effective because they can determine anti-islanding condition very fast.ΔP/P>38.41% could determine anti-islanding condition within 0.04 s;ΔP/P<-24.39% could determine anti-islanding condition within 0.04 s;-24.39%≤ΔP/P≤ 38.41% could determine anti-islanding condition within 0.08 s. This method perturbed the system, only in the case of-24.39% ≤ΔP/P ≤38.41% at which the control system of inverter injected a signal of undervoltage shift as necessary to check if the occurrence condition was an islanding condition or not.


2017 ◽  
Vol 7 (1) ◽  
pp. 214-221
Author(s):  
Motoki Sano ◽  
Ryo Kimura ◽  
Hirotaka Takano ◽  
Hisao Taoka ◽  
Kensuke Tsutsumi ◽  
...  

Author(s):  
T. NARASIMHA PRASAD ◽  
V. LAKSHMI DEVI

Solar energy has become a very potential new energy; Connected directly with grid-connected photovoltaic (PV) systems does not require bulk and lossy battery. Distributed generation and on-site supply of PV system reduces losses of transmission and distribution, and mitigates environment pollution. This paper establishes a Dynamic model of grid-connected PV system by Matlab/Simulink with d-and q-axis as coordinates which is synchronously rotating with the grid voltage to reflect the characteristics of the system accurately. Based on the accurate modeling system, optimum control and fault analysis are studied. The simulation and analysis verify the effectiveness of the proposed algorithm, and demonstrate that the proposed control system has good static performance.


Author(s):  
Syafaruddin Syafaruddin

It is crucial to improve the photovoltaic (PV) system efficiency and to develop the reliability of PV generation control systems. One of the approaches to increase the efficiency of PV power generation system is to operate the PV systems optimally at the maximum power point. However, the PV system can be optimally operated only at a specific output voltage; otherwise the output power fluctuates under intermittent weather conditions. In addition, it is very difficult to test the performance of PV systems controller under the same weather condition during the development process where the field testing is costly and time consuming. For these reasons, the presentation is about the state of the art techniques to track the maximum available output power of photovoltaic systems called maximum power point tracking (MPPT) control systems. This topic could be also one of the most challenges in photovoltaic systems application that has been receiving much more attention worldwide. The talks will cover the application of intelligent techniques by means the artificial neural network (ANN) and fuzzy logic controller scheme using polar information to develop a novel real-time simulation technique for MPPT control by using dSPACE real-time interface system. In this case, the three-layer feed-forward ANN is trained once for different scenarios to determine the global MPP voltage and power and the fuzzy logic with polar information controller takes the global maximum power point (MPP) voltage as a reference voltage to generate the required control signal for the power converter. This type of fuzzy logic rules is implemented for the first time in MPPT control application. The proposed method has been tested using different solar cell technologies such as monocrystalline silicon, thin-film cadmium telluride and triple junction amorphous silicon solar cells. The verification of availability and stability of the proposed system through the real-time simulator shows that the proposed system can respond accurately for different scenarios and different solar cell technologies. In other cases, one of the main causes of reducing energy yield of photovoltaic systems is the partially shaded condition. Although the conventional MPPT control algorithms operate well in a uniform solar irradiance, they do not operate well in non-uniform solar irradiance conditions. The non-uniform conditions cause multiple local maximum power points on the power-voltage curve. The conventional MPPT methods cannot distinguish between the global and local peaks. Since the global power point may change within a large voltage window and also its position depends on shading patterns, it is very difficult to recognize the global operating point under partially shaded conditions. From these reasons, the presentation will address the effectiveness of the proposed MPPT method to solve the partially shaded conditions under the experimental real-time simulation technique based dSPACE real-time interface system for different size of PV arrays, such as 3x3(0.5kW) and 20x3(3.3kW) and different interconnected PV arrays, for instance series-parallel (SP), bridge link (BL) and total cross tied (TCT) configurations.