scholarly journals Corrosion Behavior of A356-10 Vol.% SiC Composites Cast by Gravity and Squeeze Casting in H2SO4Solutions

2014 ◽  
Vol 2014 ◽  
pp. 1-8 ◽  
Author(s):  
A. Fattah-alhosseini ◽  
M. Ranjbaran ◽  
S. Vajdi Vahid

Corrosion behavior of A356-10 vol.% SiC composites cast by gravity and squeeze casting is evaluated. For this purpose, prepared samples were immersed in H2SO4solution for 2 hrs. at open circuit potential. Tafel polarization and electrochemical impedance spectroscopy (EIS) were carried out to study the corrosion resistance of composites. The results showed that corrosion resistance of composites cast by squeeze casting is higher than that of the gravity cast composites. The micrographs of scanning electron microscope (SEM) clearly showed the squeeze casting composites exhibit a good dispersion/matrix interface when compared with composites produced by gravity casting.

2016 ◽  
Vol 835 ◽  
pp. 115-120
Author(s):  
Francis Mulimbayan ◽  
Manolo G. Mena

All materials which are intended to have in contact with food and other commodities produced or processed for human consumption are called food contact materials (FCM’s). Stainless steel (SS) – a widely known metallic FCM is used mainly in processing equipment, containers and household utensils. It is known for having numerous industrial and domestic applications worldwide due to its special characteristics of having notable corrosion resistance. However, this corrosion resistance is not all-encompassing since SS may still undergo degradation when subjected to a specific corrosion-inducing environment. SS may be classified according to its microstructure. If the atoms which make up the SS can be viewed as having a face-centered cubic structure, then the alloy is said to be austenitic. This SS grades include the conventional 300-series and the newly-developed 200-series. The former has superior corrosion resistance while the latter is far cheaper. In this study, the corrosion behavior of AISI 202 SS in two different levels of dissolved oxygen (O2) and three acid concentrations was investigated using electrochemical techniques, namely, open-circuit potential (OCP) measurements and electrochemical impedance spectroscopy (EIS). As the concentration of citric acid is increased, the measured OCP values of the alloy decreased and the polarization resistance (Rp) decreased, indicating decrease in alloy stability and decline in the corrosion resistance, respectively. With regards to effects of dissolved O2, results revealed that increasing the level of dissolved O2 has consequently increased the polarization resistance and shifted the OCP to more positive values. All the generated Nyquist plots exhibited a depressed capacitive loops indicating that corrosion in the designated solution occurred with charge transfer as the rate-determining step.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Carmen Marina Garcia-Falcon ◽  
Tomas Gil-Lopez ◽  
Amparo Verdu-Vazquez ◽  
Julia Claudia Mirza-Rosca

Purpose This paper aims to analyze the corrosion behavior in Ringer solution of six commercially used Ni-based alloys that are present and commonly used as metallic biomaterials. Design/methodology/approach The specimens were received in the form of cylindrical ingots and were cut to get five samples of each brand with a cylindrical shape of 2 mm height to conduct the study. In this scientific research, the following techniques were used: open circuit potential, potentiodynamic polarization studies, and electrochemical impedance spectroscopy. Findings The study findings revealed the passivation tendency of the different specimens. Additionally, when the materials were compared, it was discovered that the decisive factor for high corrosion resistance was the chromium concentration. However, with similar chromium content, the stronger concentration in molybdenum increased the resistance. According to the results obtained in this investigation, the biological safety of the dental materials studied in Ringer solution was considered very high for specimens 1 and 2, and adequate for the other samples. Originality/value Metal alloys used as biomaterials in contact with the human body should be deeply investigated to make sure they are biocompatible and do not cause any harm. The corrosion resistance of an alloy is the most important characteristic for its biological safety, as all problems arise because of the corrosion process. There is scarce investigation in these Ni-based dental biomaterials, and none found in these commercially used dental materials in Ringer solution.


2011 ◽  
Vol 686 ◽  
pp. 21-25
Author(s):  
Xian Long Cao ◽  
Fu Sheng Pan ◽  
Hong Da Deng ◽  
Wei Cai

This present work investigated the corrosion behavior of AZ31 magnesium alloy substrates pre-treated with bis-[triethoxysilylpropyl] tetrasulfide silane modified with cerium nitrate. The corrosion behavior of the pre-treated substrates in 0.005M sodium chloride solutions was assessed by potentiodynamic polarization, open circuit potential and electrochemical impedance spectroscopy (EIS). The results showed that the silane pre-treatments improved the corrosion resistance of the AZ31 magnesium alloy substrates in the presence of chloride ions. Especially the addition of cerium nitrate played an important role in reducing the corrosion activity.


2015 ◽  
Vol 761 ◽  
pp. 407-411 ◽  
Author(s):  
Muhammad Zaimi ◽  
Mohd Asyadi Azam ◽  
Azizul Helmi Sofian ◽  
Kazuhiko Noda

Zinc and copper addition into electroless Ni-P alloy matrix produces quaternary Ni alloy that exhibits lower corrosion resistance behavior compared to Ni-P and Ni-Cu-P alloy in 3.5 wt% NaCl solution. The corrosion behavior of the alloy is previously studied using the anodic polarization curve measurement. The results show that the corrosion potential of different alloy composition is almost similar to each other for electroless Ni-Zn-Cu-P alloy. However, the surface resistance of the alloy needs to be confirmed by using electrochemical impedance spectroscopy. The alloy was first deposited on an iron substrate using electroless Ni alloy deposition method approximately similar thickness at different plating bath pH of 8.50 and 9.50. The Ni alloy coated substrate was used as working electrode immersed into a solution of 3.5 wt% NaCl. The electrochemical cell consists of Pt and Ag/AgCl/KCl (saturated) as counter and reference electrode respectively. Electrochemical impedance measurement was done at open circuit potential. The measurement started from 100 kHz to 10 mHz with 10 mV of sinusoidal perturbation applied to the cell. Other types of alloy including Ni-P, Ni-Cu-P and Ni-Zn-P, were compared with Ni-Zn-Cu-P alloy. From the results, the Ni-Zn-Cu-P exhibits the lowest corrosion behavior compared to other Ni alloy due to low charge transfer resistance (Rct) observed small inductive loop at low frequency region of the Nyquist plot. Furthermore, the Nyquist plot for Ni-Zn-Cu-P for pH 8.50 and 9.50 showed comparable result; hence, the effect of pH has less effect on corrosion resistance of the electroless Ni-Zn-Cu-P alloy.


2013 ◽  
Vol 83 (5) ◽  
pp. 864-869 ◽  
Author(s):  
Elisa J. Kassab ◽  
José Ponciano Gomes

ABSTRACT Objective: To assess the influence of fluoride concentration on the corrosion behavior of nickel titanium (NiTi) superelastic wire and to compare the corrosion resistance of NiTi with that of beta titanium alloy in physiological solution with and without addition of fluoride. Materials and Methods: NiTi corrosion resistance was investigated through electrochemical impedance spectroscopy and anodic polarization in sodium chloride (NaCl 0.15 M) with and without addition of 0.02 M sodium fluoride (NaF), and the results were compared with those associated with beta titanium. The influence of fluoride concentration on NiTi corrosion behavior was assessed in NaCl (0.15 M) with and without 0.02, 0.04, 0.05, 0.07, and 0.12 M NaF solution. Galvanic corrosion between NiTi and beta titanium were investigated. All samples were characterized by scanning electron microscopy. Results: Polarization resistance decreased when NaF concentration was increased, and, depending on NaF concentration, NiTi can suffer localized or generalized corrosion. In NaCl solution with 0.02 M NaF, NiTi suffer localized corrosion, while beta titanium alloys remained passive. Current values near zero were observed by galvanic coupling of NiTi and beta titanium. Conclusions: There is a decrease in NiTi corrosion resistance in the presence of fluoride. The corrosion behavior of NiTi alloy depends on fluoride concentration. When 0.02 and 0.04 M of NaF were added to the NaCl solution, NiTi presented localized corrosion. When NaF concentration increased to 0.05, 0.07, and 0.12 M, the alloy presented general corrosion. NiTi corrosion resistance behavior is lower than that of beta titanium. Galvanic coupling of these alloys does not increase corrosion rates.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Yucong Ma ◽  
Mohd Talha ◽  
Qi Wang ◽  
Zhonghui Li ◽  
Yuanhua Lin

Purpose The purpose of this paper is to study systematically the corrosion behavior of AZ31 magnesium (Mg) alloy with different concentrations of bovine serum albumin (BSA) (0, 0.5, 1.0, 1.5, 2.0 and 5.0 g/L). Design/methodology/approach Electrochemical impedance spectroscopy and potential dynamic polarization tests were performed to obtain corrosion parameters. Scanning electrochemical microscopy (SECM) was used to analyze the local electrochemical activity of the surface film. Atomic force microscope (AFM), Scanning electron microscope-Energy dispersive spectrometer and Fourier transform infrared spectroscopy were used to determine the surface morphology and chemical composition of the surface film. Findings Experimental results showed the presence of BSA in a certain concentration range (0 to 2.0 g/L) has a greater inhibitory effect on the corrosion of AZ31, however, the presence of high-concentration BSA (5.0 g/L) would sharply reduce the corrosion resistance. Originality/value When the concentration of BSA is less than 2.0 g/L, the corrosion resistance of AZ31 enhances with the concentration. The adsorption BSA layer will come into being a physical barrier to inhibit the corrosion process. However, high-concentration BSA (5.0 g/L) will chelate with dissolved metal ions (such as Mg and Ni) to form soluble complexes, which increases the roughness of the surface and accelerates the corrosion process.


Coatings ◽  
2019 ◽  
Vol 9 (11) ◽  
pp. 758 ◽  
Author(s):  
Yang ◽  
Zhang ◽  
Wang ◽  
Wang ◽  
Chen ◽  
...  

Pure Zn and Zn–ERGO composite coatings were prepared by direct current electrodeposition on 304 stainless steel. Samples were characterized by X-ray diffraction (XRD), scanning electron microscopy coupled with energy dispersive X-ray spectroscopy (SEM/EDS), and laser Raman spectroscopy (Raman). Results obtained have shown that the concentration of GO sheets in zinc sulfate electrolyte has an important effect on the preferred crystal orientation and the surface morphology of Zn–ERGO composite coatings. A study of the corrosion behavior of the coatings by Tafel polarization and electrochemical impedance spectroscopic (EIS) methods leads to the conclusion that the Zn-1.0 g/L ERGO composite coating possesses the best corrosion resistance compared to the pure Zn coating and other composite coatings in this study.


Metals ◽  
2019 ◽  
Vol 9 (12) ◽  
pp. 1325 ◽  
Author(s):  
Jian-Bao Wang ◽  
Guang-Chun Xiao ◽  
Wei Zhao ◽  
Bing-Rong Zhang ◽  
Wei-Feng Rao

The microstructure and corrosion resistance in H2S environments for various zones of X80 pipeline steel submerged arc welded joints were studied. The main microstructures in the base metal (BM), welded metal (WM), coarse-grained heat-affected zone (CGHAZ), and fine-grained heat-affected zone (FGHAZ) were mainly polygonal ferrite and granular bainite; acicular ferrite with fine grains; granular bainite, ferrite, and martensite/austenite constituents, respectively. The corrosion behavior differences resulted from the microstructure gradients. The results of the micro-morphologies of the corrosion product films and the electrochemical corrosion characteristics in H2S environments, including open circuit potential and electrochemical impedance spectroscopy, showed that the order of corrosion resistance was FGHAZ > BM > WM > CGHAZ.


Coatings ◽  
2020 ◽  
Vol 10 (11) ◽  
pp. 1042
Author(s):  
Panneer Selvam Kevin ◽  
Abhishek Tiwari ◽  
Saravanan Seman ◽  
Syed Ali Beer Mohamed ◽  
Rengaswamy Jayaganthan

Cr3C2–NiCr coatings have been used extensively to combat the erosion corrosion of hydro power turbine blades made of stainless steel. Cr3C2–NiCr coatings are also used in aqueous corrosive environments due to the high corrosion resistance rendered by the NiCr binder. In this investigation, both erosion and corrosion environments are introduced to cermet coating to study corrosion behavior using potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) techniques. The cermet coatings are useful for reducing the risk of deterioration of mechanical properties of hydro power turbines due to the continuous exposure to the erosive and corrosive action of the corrosive environment containing silt. It was observed that Cr3C2–NiCr coating offered a reasonable improvement in corrosion resistance when compared to bare substrate. The corrosion behavior of the coating was studied in a 150 mL solution of 0.1 M NaCl with 2 gms of quartz particles (0.2–0.8 mm) at various rotation speeds (3000, 4500, 6000 rpm) of the solution over a 1 h immersion using potentiodynamic polarization and EIS studies in a specifically designed experimental set-up for erosion corrosion. When compared to the bare stainless steel samples at 3000 rpm and 6000 rpm, the coating showed the highest improvement at 6.57 times and the least improvement at 3.79 times, respectively.


2019 ◽  
Vol 31 (4) ◽  
pp. 891-895
Author(s):  
Dinesh Kumar Chelike ◽  
K. Juliet Gnana Sundari

Considering the good corrosion resistance of Zn-Ni alloy, it is selected in the present study to be the protective coating on mild steel and it is considered as a strong candidate for the replacement of environmentally hazardous cadmium. Zn-Ni alloy coating is applied by electrodeposition at optimum temperature, current density and time. The bath solution used is consisting of EDTA as complexing agent. The electrodeposition is also carried out with tartaric acid and benzaldehyde additives to have good corrosion resistance and brightness. The electrodeposits obtained with and without additives are examined for nature and alloy composition. The corrosion behaviour of the electrodeposits is studied by Tafel polarization and electrochemical impedance spectroscopy.


Sign in / Sign up

Export Citation Format

Share Document