scholarly journals Numerical Study on Different Series Modes of Jet Fan in a Longitudinal Tunnel Ventilation System

2014 ◽  
Vol 2014 ◽  
pp. 1-9 ◽  
Author(s):  
Guihong Pei ◽  
Jie Pan

Efficient ventilation systems will contribute to maintaining air quality in the tunnel. In order to improve ventilation performance in normal traffic condition, the 3D tunnel models were established according to the original design for the tunnel located in central plains of China. Based on the commercial CFD software Fluent 6.3 andk-εturbulence model, numerical simulations were carried out to study the patterns of jet flow and the optimization of fan combinations. It is found that the axial velocity profile obtained from numerical simulation agrees quite well with turbulent free jet theory although there is a little difference on the magnitude. The comparison of four combination modes under the condition of operating four fans indicates that the ventilation effectiveness is affected mainly by both the interval of adjacent groups of fans and the combination modes of operational fans. According to the simulation results, a novel combination mode which consists of a group double paralleled fans and two groups single fan is designed. The novel combination mode is regarded as the optimum combination mode with respect to maximizing air velocity in the tunnel. Compared to the traditional combination modes, it will increase the air velocity by 5.7%.

2014 ◽  
Vol 2014 ◽  
pp. 1-15 ◽  
Author(s):  
M. Z. I. Bangalee ◽  
J. J. Miau ◽  
S. Y. Lin ◽  
M. Ferdows

Energy is saved when an effective natural ventilation system can provide comfort air to the occupants in a building by replacing a mechanical ventilation system. It also minimizes the risk of the environmental pollution and the global warming. A one story, full scale building was considered to carry out a comparative study of three different cases of wind-driven natural (WDN) cross ventilation with the help of computational fluid dynamics (CFD). In each case, the location of window was changed in lateral direction to predict the probable position for optimum ventilation performance and the angle of wind was varied to check the sensitivity of the wind direction on the flow field. After validating the current methodology through two satisfactory comparisons with the experimental investigations, the governing equations subjected to the corresponding boundary conditions were solved using commercial software and then the results were analyzed. A better location for the windows in each case was proposed. The ventilation purpose was served quite well even if the wind angle was changed in a moderate range from the original design. Furthermore, the velocity components, ventilation rate, surface pressure, ventilation time, and so forth in each case were investigated and compared extensively with those in other cases.


Energies ◽  
2020 ◽  
Vol 13 (9) ◽  
pp. 2314
Author(s):  
Jau-Woei Perng ◽  
Yi-Chang Kuo ◽  
Yao-Tsung Chang ◽  
Hsi-Hsiang Chang

This study discusses a numerical study that was developed to optimize the ventilation system in a power substation prior to its installation. We established a multiobjective particle swarm optimizer to identify the best approach for simultaneously improving, first, the ventilation performance considering the most appropriate inlet size and outlet openings and second, the reduction of the synthetic noise of the ventilation and power consumption from the exhaust fan equipment and its operation. The study used building information modeling to construct indoor and outdoor models of the substation building and verified the overall performance using ANSYS FLUENT 18.0 software to simulate the air velocity and air temperature distribution within the building. Results show that the exhaust fan of the B1F cable finishing room and the 23 kV gas insulated switchgear (GIS) room optimize the reduction of horsepower by approximately 1 Hp and 0.5 Hp. The combined noise is reduced by 4 dBA and 2 dBA; the exhaust fan runs for 30 min, and the two equipment rooms can cool down by 2.9 °C and 1.7 °C, respectively. Therefore, it is confirmed that the MOPSO algorithm provides a more energy-efficient and environmentally friendly building ventilation environment.


Author(s):  
K. Y. Wong ◽  
H. M. Kamar ◽  
N. Kamsah

This article presents the results of a numerical study to examine the transport of particles in an operating room equipped with an Econoclean ventilation system. Its aims are to reduce the number of particles falling onto the operating table. A simplified CFD model of the operating room was developed and validated based on the measured air velocity distribution. An SST k-ω turbulent flow model was used to simulate the airflow, while a discrete phase model was used to simulate the movement of the airborne particles. The effects of the standing posture of the surgical staff on the settlement of the particles on the operating table were examined. Results show that under the present ventilation system, when the surgical staff bend forward at an angle of 45°,  the number of airborne particles that tend to fall onto the operating table increased by 1.4-fold. Adding an exhaust grille to the operating room does not have any significant effects on the distribution of the airborne particles. However, when a larger air supply diffuser is also used, the number of airborne particles that settled on the operating table was reduced 4-fold. More airborne particles are transported towards the exhaust grilles, and more airborne particles accumulate below the operating table. The present study shows that the usage of large air supply diffuser in the operating room is capable of reducing the number of airborne particles fall onto the operating table. Also, it enhances the efficiency of airborne particle removal.


2019 ◽  
Vol 85 ◽  
pp. 02014 ◽  
Author(s):  
Paul Dancă ◽  
Florin Bode ◽  
Ilinca Năstase ◽  
Cristiana Verona Croitoru ◽  
Amina Meslem

The main declared goal of all car manufacturers is to ensure high comfort inside the cabin and to reduce the fossil fuel. It is well-known that the time spent by the people indoor has raised in the last decade. The distance between the home and the workplace increased due to diversity of activities and hence job diversity. The thermal comfort during the travel must to be ensured to reduce the occupant’s thermal stress. The present study is investigating a comparison between the measured data and the numerical simulation results in the case when the ventilation system is functioning. It was evaluated the effect of the boundary conditions air flow and air velocity distribution in a passenger compartment in two cases: first is the general used constant inlet flow and the second is a new approach of importing the measured data obtained during the experimental measurement session as a boundary condition.CFD simulations were made taking as input the measured data obtained during experimental session. We have observed differences between initial simulation results and the measured data, therefore, for more accurate results, a new approach is needed, to impose as boundary conditions the measured data.


2020 ◽  
Vol 38 (9A) ◽  
pp. 1257-1275
Author(s):  
Wisam M. Mareed ◽  
Hasanen M. Hussen

 Elevated CO2 rates in a building affect the health of the occupant. This paper deals with an experimental and numerical analysis conducted in a full-scale test room located in the Department of Mechanical Engineering at the University of Technology. The experiments and CFD were conducted for analyzing ventilation performance. It is a study on the effect of the discharge airflow rate of the ceiling type air-conditioner on ventilation performance in the lecture room with the mixing ventilation. Most obtained findings show that database and questionnaires analyzed prefer heights between 0.2 m to 1.2 m in the middle of an occupied zone and breathing zone height of between 0.75 m to 1.8 given in the literature surveyed. It is noticed the mismatch of internal conditions with thermal comfort, and indoor air quality recommended by [ASHRAE Standard 62, ANSI / ASHRAE Standard 55-2010]. CFD simulations have been carried to provide insights on the indoor air quality and comfort conditions throughout the classroom. Particle concentrations, thermal conditions, and modified ventilation system solutions are reported.


Author(s):  
Adra Benhacine ◽  
Zoubir Nemouchi ◽  
Lyes Khezzar ◽  
Nabil Kharoua

A numerical study of a turbulent plane jet impinging on a convex surface and on a flat surface is presented, using the large eddy simulation approach and the Smagorinski-Lilly sub-grid-scale model. The effects of the wall curvature on the unsteady filtered, and the steady mean, parameters characterizing the dynamics of the wall jet are addressed in particular. In the free jet upstream of the impingement region, significant and fairly ordered velocity fluctuations, that are not turbulent in nature, are observed inside the potential core. Kelvin-Helmholtz instabilities in the shear layer between the jet and the surrounding air are detected in the form of wavy sheets of vorticity. Rolled up vortices are detached from these sheets in a more or less periodic manner, evolving into distorted three dimensional structures. Along the wall jet the Coanda effect causes a marked suction along the convex surface compared with the flat one. As a result, relatively important tangential velocities and a stretching of sporadic streamwise vortices are observed, leading to friction coefficient values on the curved wall higher than those on the flat wall.


2021 ◽  
Vol 13 (9) ◽  
pp. 4748
Author(s):  
Edwin Villagran ◽  
Carlos Bojacá ◽  
Mohammad Akrami

The use of covered structures is an alternative increasingly used by farmers to increase crop yields per unit area compared to open field production. In Latin American countries such as Colombia, productive areas are located in with predominantly hillside soil conditions. In the last two decades, farmers have introduced cover structures adapted to these soil conditions, structures for which the behavior of factors that directly affect plant growth and development, such as microclimate, are still unknown. Therefore, in this research work, a CFD-3D model successfully validated with experimental data of temperature and air velocity was implemented. The numerical model was used to determine the behavior of air flow patterns and temperature distribution inside a Colombian passive greenhouse during daytime hours. The results showed that the slope of the terrain affects the behavior of the air flow patterns, generating thermal gradients inside the greenhouse with values between 1.26 and 16.93 °C for the hours evaluated. It was also found that the highest indoor temperature values at the same time were located in the highest region of the terrain. Based on the results of this study, future researches on how to optimize the microclimatic conditions of this type of sustainable productive system can be carried out.


Author(s):  
Li Yabing ◽  
Zhang Han ◽  
Xiao Jianjun

A dynamic film model is developed in the parallel CFD code GASFLOW-MPI for passive containment cooling system (PCCS) utilized in nuclear power plant like AP1000 and CAP1400. GASFLOW-MPI is a widely validated parallel CDF code and has been applied to containment thermal hydraulics safety analysis for different types of reactors. The essential issue for PCCS is the heat removal capability. Research shows that film evaporation contributes most to the heat removal capability for PCCS. In this study, the film evaporation model is validated with separate effect test conducted on the EFFE facility by Pisa University. The test region is a rectangle gap with 0.1m width, 2m length, and 0.6m depth. The water film flowing from the top of the gap is heated by a heating plate with constant temperature and cooled by countercurrent air flow at the same time. The test region model is built and analyzed, through which the total thermal power and evaporation rate are obtained to compare with experimental data. Numerical result shows good agreement with the experimental data. Besides, the influence of air velocity, wall temperature and gap widths are discussed in our study. Result shows that, the film evaporation has a positive correlation with air velocity, wall temperature and gap width. This study can be fundamental for our further numerical study on PCCS.


2018 ◽  
Vol 4 (7) ◽  
pp. 1521 ◽  
Author(s):  
Fang Lin

Construction ventilation system is divided into two stages based on completion status of shafts in the underground petroleum storage project in Jinzhou, China. With the help of theoretical analysis and numerical simulations by using FLUENT software, in the first stage, reasonable construction ventilation is designed and cases with different outside temperature are discussed to investigate the effect of ventilation performance. It is found that with temperature difference increases, peak value of CO concentration, exhausting time of dirty air and required time to meet the CO concentration qualification decrease, but the influence degree is quite limited. Gallery-type network ventilation technique (GNVT) refined from theories of operation ventilation for road tunnel and mining ventilation network, is proposed to conduct the second stage construction ventilation. Ventilation performance of different ventilation schemes with various shafts’ states and diverse arrangements of fans are also analyzed in this study. It turns out that Axial-GNVT with shafts taking in fresh air and access tunnel ejecting dirty air has much better performance than traditional forced ventilation from access tunnel. Improved energy saving scheme is finally adopted to guide the construction. In addition, it is worth mentioning that there is no need to build middle ventilation shafts and construct shafts as large and long as possible. Field test of wind speed, dust, poisonous gas, atmospheric pressure, temperature are performed to detect ventilation effectiveness. Reduction coefficient =0.69is obtained from the test results in consideration of super-large section and it also indicates that there is no difference if the axial fan is at the shaft mouth or in the bottom.