scholarly journals Numerical Study of Natural Convection Heat Loss from Cylindrical Solar Cavity Receivers

2014 ◽  
Vol 2014 ◽  
pp. 1-7 ◽  
Author(s):  
M. Prakash

The numerical study of the natural convection loss occurring from cylindrical solar cavity receivers is reported in this communication. These cavity receivers can be used with solar dish concentrators for process heat applications at medium temperature levels. Three cylindrical cavity receivers of diameter 0.2, 0.3, and 0.4 m with aspect ratio equal to one and opening ratios of 1 and 0.5 are used for the analysis. Fluent CFD software is used for the analysis of the three-dimensional (3D) receiver models. In this study the receiver tubes within the cylindrical cavity are modeled as a helical coil similar to those existing in actual systems. The flow of the working fluid within the helical coil is also modeled. The simulations are performed for fluid inlet temperatures of 150°C and 250°C and for receiver inclination angles of 0 (sideways-facing cavity), 30, 45, 60, and 90 degree (vertically downward-facing receiver). It is found that the convective loss increases with increasing mean fluid temperature and decreases with, increase in receiver inclination. The convective loss is found to increase with, opening ratio. These observations are true for all cavity receivers analysed here. A Nusselt number correlation involving Rayleigh numbers, receiver inclinations, and opening ratios is proposed for the convective loss.

Author(s):  
C. Abegg ◽  
Graham de Vahl Davis ◽  
W.J. Hiller ◽  
St. Koch ◽  
Tomasz A. Kowalewski ◽  
...  

2016 ◽  
Vol 831 ◽  
pp. 83-91
Author(s):  
Lahoucine Belarche ◽  
Btissam Abourida

The three-dimensional numerical study of natural convection in a cubical enclosure, discretely heated, was carried out in this study. Two heating square sections, similar to the integrated electronic components, are placed on the vertical wall of the enclosure. The imposed heating fluxes vary sinusoidally with time, in phase and in opposition of phase. The temperature of the opposite vertical wall is maintained at a cold uniform temperature and the other walls are adiabatic. The governing equations are solved using Control volume method by SIMPLEC algorithm. The sections dimension ε = D / H and the Rayleigh number Ra were fixed respectively at 0,35 and 106. The average heat transfer and the maximum temperature on the active portions will be examined for a given set of the governing parameters, namely the amplitude of the variable temperatures a and their period τp. The obtained results show significant changes in terms of heat transfer, by proper choice of the heating mode and the governing parameters.


Energies ◽  
2018 ◽  
Vol 11 (11) ◽  
pp. 2960 ◽  
Author(s):  
Carlo Renno

The knowledge of the actual energy performances of a concentrating photovoltaic and thermal (CPV/T) system with a linear focus optics, allows to evaluate the possibility of adopting this type of system for cogeneration purposes. Hence, the main aim of this paper is the design, realization, setting and modeling of a linear focus CPV/T system in the high concentration field. An experimental linear focus CPV/T plant was created in order to determine its electrical and thermal performance under different working conditions in terms of environment temperature, sunny and cloudy conditions, focal length, etc. Moreover, a theoretical model of the linear focus CPV/T system was also studied. This model evaluates the temperatures of the working fluid that flows in the cooling circuit of the CPV/T system under several operating conditions. The temperatures of the triple junction (TJ) cells, experimentally evaluated referring to different solar radiation and atmospheric conditions, were considered as the input data for the model. The values of the fluid temperature, theoretically and experimentally determined, were thus compared with good agreement. The electrical production of the CPV/T system depends generally on the TJ cell characteristics and the concentration factor, while the thermal production is above all linked to the system configuration and the direct normal irradiance (DNI) values. Hence, in this paper the electric power obtained by the linear-focus CPV/T system was evaluated referring to the cogeneration applications, and it was verified if the TJ cell and the cooling fluid reach adequate temperature levels in this type of system, in order to match the electrical and the thermal loads of a user.


2021 ◽  
pp. 57-57
Author(s):  
Zakaria Lafdaili ◽  
Sakina El-Hamdani ◽  
Abdelaziz Bendou ◽  
Karim Limam ◽  
Bara El-Hafad

In this work we study numerically the three-dimensional turbulent natural convection in a partially heated cubic cavity filled with water containing metallic nanoparticles, metallic oxides and others based on carbon.The objective is to study and compare the effect of the addition of nanoparticles studied in water and also the effect of the position of the heated partition on the heat exchange by turbulent natural convection in this type of geometry, which can significantly improve the design of heat exchange systems for better space optimization. For this we have treated numerically for different volume fractions the turbulent natural convection in the two cases where the cavity is heated respectively by a vertical and horizontal strip in the middle of one of the vertical walls. To take into account the effects of turbulence, we used the standard turbulence model ? - ?. The governing equations are discretized by the finite volume method using the power law scheme which offers a good stability characteristic in this type of flow. The results are presented in the form of isothermal lines and current lines. The variation of the mean Nusselt number is calculated for the two positions of the heated partition as a function of the volume fraction of the nanoparticles studied in water for different Rayleigh numbers.The results show that carbon-based nanoparticles intensify heat exchange by convection better and that the position of the heated partition significantly influences heat exchange by natural convection. In fact, an improvement in the average Nusselt number of more than 20% is observed for the case where the heated partition is horizontal.


Author(s):  
S. Shahsavari ◽  
M. B. Shafii ◽  
M. H. Saidi

Thermopneumatic micropump is one type of positive displacement micropump, which has many applications due to its relatively large stroke volume, low working voltage, and simple fabrication in microscale. In this paper, a numerical study of heat transfer and fluid flow in a valveless thermopneumatically driven micropump is presented. For rectifying the bidirectional flow, a nozzle and a diffuser are used as the inlet and outlet channels of the chamber. Since the fluid flow is induced by the motion of a diaphragm, the numerical simulation includes fluid structure interaction, which requires applying a dynamic mesh. The domain of solution is divided into two sections; the actuator unit, which contains the secondary fluid, and the main chamber through which the working fluid is passing. The temperature distribution, the pressure variations, and the center deflection of the diaphragm are obtained. In order to validate the model, the numerical results are compared with some experimental data, which shows fair consistency. According to the results of the three dimensional simulation, the rectification efficiency for the nozzle and diffuser channels depends on the frequency.


2016 ◽  
Vol 138 (9) ◽  
Author(s):  
Amin Bouraoui ◽  
Rachid Bessaïh

In this paper, a numerical study of three-dimensional (3D) natural convection air-cooling of two identical heat sources, simulating electronic components, mounted in a rectangular enclosure was carried out. The governing equations were solved by using the finite-volume method based on the SIMPLER algorithm. The effects of Rayleigh number Ra, spacing between heat sources d, and aspect ratios Ax in x-direction (horizontal) and Az in z-direction (transversal) of the enclosure on heat transfer were investigated. In steady state, when d is increased, the heat transfer is more important than when the aspect ratios Ax and Az are reduced. In oscillatory state, the critical Rayleigh numbers Racr for different values of spacing between heat sources and their aspect ratios, at which the flow becomes time dependent, were obtained. Results show a strong relation between heat transfers, buoyant flow, and boundary layer. In addition, the heat transfer is more important at the edge of each face of heat sources than at the center region.


2000 ◽  
Vol 123 (1) ◽  
pp. 77-83 ◽  
Author(s):  
Shunichi Wakitani

Numerical investigations are presented for three-dimensional natural convection at low Prandtl numbers (Pr) from 0 to 0.027 in rectangular enclosures with differentially heated vertical walls. Computations are carried out for the enclosures with aspect ratios (length/height) 2 and 4, and width ratios (width/height) ranging from 0.5 to 4.2. Dependence of the onset of oscillation on the Prandtl number, the aspect ratio, and the width ratio is investigated. Furthermore, oscillatory, three-dimensional flow structure is clarified. The structure is characterized by some longitudinal vortices (rolls) as well as cellular pattern.


2017 ◽  
Vol 139 (6) ◽  
Author(s):  
V. S. Duryodhan ◽  
Shiv Govind Singh ◽  
Amit Agrawal

Aspect ratio is an important parameter in the study of flow through noncircular microchannel. In this work, three-dimensional numerical study is carried out to understand the effect of cross aspect ratio (height to width) on flow in diverging and converging microchannels. Three-dimensional models of the diverging and converging microchannels with angle: 2–14 deg, aspect ratio: 0.05–0.58, and Reynolds number: 130–280 are employed in the simulations with water as the working fluid. The effects of aspect ratio on pressure drop in equivalent diverging and converging microchannels are studied in detail and correlated to the underlying flow regime. It is observed that for a given Reynolds number and angle, the pressure drop decreases asymptotically with aspect ratio for both the diverging and converging microchannels. At small aspect ratio and small Reynolds number, the pressure drop remains invariant of angle in both the diverging and converging microchannels; the concept of equivalent hydraulic diameter can be applied to these situations. Onset of flow separation in diverging passage and flow acceleration in converging passage is found to be a strong function of aspect ratio, which has not been shown earlier. The existence of a critical angle with relevance to the concept of equivalent hydraulic diameter is identified and its variation with Reynolds number is discussed. Finally, the effect of aspect ratio on fluidic diodicity is discussed which will be helpful in the design of valveless micropump. These results help in extending the conventional formulae made for uniform cross-sectional channel to that for the diverging and converging microchannels.


Sign in / Sign up

Export Citation Format

Share Document