scholarly journals Susceptibility to Stress Corrosion of Laser-Welded Composite Arch Wire in Acid Artificial Saliva

2013 ◽  
Vol 2013 ◽  
pp. 1-8
Author(s):  
Chao Zhang ◽  
Xinhua Sun

The corrosion resistance of laser-welded composite arch wire (CoAW) with Cu interlayer between NiTi shape memory alloy and stainless steel wire in artificial saliva with different acidities and loads was studied. It was found that both the solution pH and the stress had a significant influence on the corrosion behaviors of the CoAW samples. Decreasing the solution pH or increasing the loading stress caused the increase of Cu release and weight loss. The corroded morphology formed on the surfaces of the CoAW was the consequence under the combined effect of corrosion and stress.

2014 ◽  
Vol 884-885 ◽  
pp. 560-565 ◽  
Author(s):  
Wassana Wichai ◽  
Niwat Anuwongnukroh ◽  
Surachai Dechkunakorn

Objective: This study aimed to determine the composition and corrosion resistance of stainless steel and nickel titanium (NiTi) archwires and to compare Ni released from simulated standard fixed orthodontic appliances ligated with stainless steel and NiTi wires in artificial saliva at pH 5.14 and pH 6.69. in 4 weeks at 37oC. Materials and Method: Two commercial rectangular wires, 0.016 x 0.022 in size were studied, one Ormco stainless steel wire and another Ormco nickel titanium wire. Their composition was analyzed by an energy disporsive X-ray spectrometer (ESC) and their corrosion resistance was evaluated by a potentiodynamic polarization technique. For Ni release, the twenty-eight simulated fixed appliance sample sets were used, each corresponding to one half-maxillary arch. The samples were divided in 2 groups (14 sets per group). The first one was ligated to Ormco stainless steel archwires and the other one to Ormco NiTi archwires with elastomeric ligatures. Half sets of each group were immersed in 50 ml artificial saliva at pH 5.14 and the other half were immersed at pH 6.69. Ni release was quantified using flame atomic absorption spectrophotometry. Statistical analysis of variance (t-test) was determined on days 1, 4, 7, 9, 14, 21 and 28 comparing the amount of Ni released between groups. Results: Stainless steel wire was composed of Ni, Cr, Si, Mn and Fe while the nickel titanium wire was composed of Ti, Ni and Cr. NiTi wire has more percentage of Ni and therefore has less corrosion resistance than stainless steel wire. For Ni release, stainless steel and NiTi continuously increased at the time intervals for both pH levels. For group one, stainless steel wire had more Ni release at pH 5.14 and for the other group, NiTi wire had more Ni-release at pH 6.69. At 4 weeks, the Ni release of one half-maxillary arch was 1.383 ppm (1383 μg/l) at pH 5.14 and 1.079 ppm (1078 μg/l) at pH 6.69 for stainless steel wire while it was 1.221 ppm (1221 μg/l) at pH 5.14 and 1.267 ppm (1267μg/l) at pH 6.69 for NiTi wire. No significant difference was found in the amount of Ni release from stainless steel and NiTi wires at pH 5.14 and pH 6.69 in the different time intervals except on day 1 wherein the stainless steel archwire was significantly different (p<0.05) at pH 5.14 and pH 6.69. Conclusions: The NiTi wire had more Ni contain and less corrosion resistance than stainless steel wire. Stainless steel had more Ni release at pH 5.14 than pH 6.69 but NiTi had greater Ni release at pH 6.69 than pH 5.14.


2015 ◽  
Vol 1114 ◽  
pp. 258-265 ◽  
Author(s):  
Diana Maria Vrânceanu ◽  
Mihai Tarcolea ◽  
Ana Iulia Gherghilescu ◽  
Florin Miculescu ◽  
Mihai Cosmin Cotrut

Typical applications of metallic dental materials include metal-ceramic restorations, dental implants or orthodontic systems. Due to their contact with human tissues, corrosion resistance is one of the main requirements for dental materials. In the present paper, the corrosion behaviour in Fusayama Meyer artificial saliva solution (pH=5.2) on a selection of four different metallic dental materials (316 L steel, Au based alloy, cp-Ti, Ti6Al4V alloy) currently used in dentistry were investigated. The metallic dental materials have been investigated in terms of electrochemical analysis, chemical composition, morphology before and after corrosion, wettability and roughness. The results showed a hydrophilic behaviour in the case of Au based alloy, cp-Ti and Ti6Al4V alloy, and hydrophobic for 316L stainless steel. Considering the main electrochemical parameters, the cp-Ti alloy exhibited better corrosion resistance in artificial saliva with pH=5.2, followed by Au based alloy, Ti6Al4V alloy and 316L stainless steel. The main objective of the present paper was to evaluate the corrosion behaviour, as in important factor in the selection of metallic materials used in dentistry.


Energies ◽  
2021 ◽  
Vol 14 (3) ◽  
pp. 543
Author(s):  
Ketan Kumar Sandhi ◽  
Jerzy Szpunar

Nickel superalloy Hastelloy-N, alloy X-750, stainless steel 316 (SS316), and stainless steel 304 (SS304) are among the alloys used in the construction of molten salt reactor (MSR). These alloys were analyzed for their corrosion resistance behavior in molten fluoride salt, a coolant used in MSR reactors with 46.5% LiF+ 11.5% NaF+ 42% KF. The corrosion tests were run at 700 °C for 100 h under the Ar cover gas. After corrosion, significant weight loss was observed in the alloy X750. Weight loss registered in SS316 and SS304 was also high. However, Hastelloy-N gained weight after exposure to molten salt corrosion. This could be attributed to electrochemical plating of corrosion products from other alloys on Hastelloy-N surface. SEM–energy-dispersive X-ray spectroscopy (EDXS) scans of cross-section of alloys revealed maximum corrosion damage to the depth of 250 µm in X750, in contrast to only 20 µm on Hastelloy-N. XPS wide survey scans revealed the presence of Fe, Cr, and Ni elements on the surface of all corroded alloys. In addition, Cr clusters were formed at the triple junctions of grains, as confirmed by SEM–EBSD (Electron Back Scattered Diffraction) analysis. The order of corrosion resistance in FLiNaK environment was X750 < SS316 < SS304 < Hastelloy-N.


2019 ◽  
Vol 66 (3) ◽  
pp. 307-316 ◽  
Author(s):  
Jun Wang ◽  
Zili Li ◽  
Gan Cui ◽  
JianGuo Liu ◽  
Chuanping Kong ◽  
...  

Purpose The purpose of this paper is to study the corrosion behaviors of X70 steel under direct current (DC) interference at 0-1,200 A/m2 in simulated soil solution. Design/methodology/approach The Tafel polarization curves of X70 steel under DC interference were tested using electrochemical method, the corrosion rate was calculated using weight-loss method and the change in steel surface was analyzed by optical microscopy. Findings The results showed that E-I polarization curves under 200-1,200 A/m2 interference were linear; with an increase in the DC density, the corrosion potential of X70 steel shifted positively, solution pH after the weight-loss tests increased and corrosion rate increased linearly. A mathematical relationship between polarization resistance Rp and current density was established. Corrosion morphology indicated that pitting corrosion and crevice corrosion occurred on the X70 steel under DC interference in simulated soil solution. Originality/value All tests were conducted at a relative higher DC density (200-1,200 A/m2). The linear fitting method is proposed to fit data of Tafel polarization curves under DC interference. This study provides guidelines for safe operation of X70 steel pipelines.


2012 ◽  
Vol 2012 ◽  
pp. 1-7 ◽  
Author(s):  
G. Salinas ◽  
J. G. Gonzalez-Rodriguez ◽  
J. Porcayo-Calderon ◽  
V. M. Salinas-Bravo ◽  
M. A. Espinoza-Medina

The hot corrosion behavior of Fe40Al intermetallic alloyed with Ag, Cu, Li, and Ni (1–5 at.%) in NaCl-KCl (1 : 1 M) at 670°C, typical of waste gasification environments, has been evaluated by using polarization curves and weight loss techniques and compared with a 304-type stainless steel. Both gravimetric and electrochemical techniques showed that all different Fe40Al-base alloys have a much higher corrosion resistance than that for stainless steel. Among the different Fe40Al-based alloys, the corrosion rate was very similar among each other, but it was evident that the addition of Li decreased their corrosion rate whereas all the other elements increased it. Results have been explained in terms of the formation and stability of an external, protective Al2O3layer.


2013 ◽  
Vol 750-752 ◽  
pp. 739-742
Author(s):  
Ying Ling Wang ◽  
Qiu Zhi Gao ◽  
Gui Fang Sun ◽  
Jie Ye

The transient liquid phase diffusion bonding (TLP-DB) was employed to join TiNi shape memory alloy (SMA) and stainless steel (SS) with an interlayer metal of Ag-Cu eutectic metal foil.The corrosion behavior of the TLP-DB joint in Hanks solution at 37°C was investigated by electrochemical methods.The results show that the corrosion resistance of the joint is comparable to, but lower than that of base metals during the early anodic polarization, and the corrosion rate of the joint is between that of TiNi SMA and SS in the transpassive region at high potentials. The corrosion resistance of the specimens in Hanks' solution is associated with the surface quality, mircotructure and the intermetallics. Both TiNi SMA and SS display the characteristics of localized corrosion with a little pitting corrosion, while the joints mainly show the characteristics of pitting corrosion concentrated on the enrichment Cu phases.


2002 ◽  
Vol 149 (9) ◽  
pp. B414 ◽  
Author(s):  
Keun-Taek Oh ◽  
Chung-Ju Hwang ◽  
Yong-Soo Park ◽  
Kyoung-Nam Kim

1996 ◽  
Vol 459 ◽  
Author(s):  
F. Villermaux ◽  
I. Nakatsugawa ◽  
M. Tabrizian ◽  
D. L. Piron ◽  
M. Meunier ◽  
...  

ABSTRACTNiTi shape memory alloy presents interesting mechanical properties as surgical implants. However, due to its high amount of Ni which may dissolve and release toxic ions in human fluids, the medical use of this material is a great concern. We have developed a laser treatment which modifies the oxide layer and enhances uniform and localised corrosion resistance of NiTi alloy.In this paper we further analysed the effect of this treatment with potentiostatic and AC impedance measurements in physiological Hank's solution. We conclude that the laser treatment creates a stable passive film which results in improved corrosion resistance of this alloy.


Sign in / Sign up

Export Citation Format

Share Document