scholarly journals Deacidification of Soybean Oil Combining Solvent Extraction and Membrane Technology

2013 ◽  
Vol 2013 ◽  
pp. 1-5 ◽  
Author(s):  
M. L. Fornasero ◽  
R. N. Marenchino ◽  
C. L. Pagliero

The aim of this work was to study the removal of free fatty acids (FFAs) from soybean oil, combining solvent extraction (liquid-liquid) for the separation of FFAs from the oil and membrane technology to recover the solvent through nanofiltration (NF). Degummed soybean oil containing 1.05 ± 0.10% w/w FFAs was deacidified by extraction with ethanol. Results obtained in the experiences of FFAs extraction from oil show that the optimal operating conditions are the following: 1.8 : 1 w : w ethanol/oil ratio, 30 minutes extraction time and high speed of agitation and 30 minutes repose time after extraction at ambient temperature. As a result of these operations two phases are obtained: deacidified oil phase and ethanol phase (containing the FFAs). The oil from the first extraction is subjected to a second extraction under the same conditions, reducing the FFA concentration in oil to 0.09%. Solvent recovery from the ethanol phase is performed using nanofiltration technology with a commercially available polymeric NF membrane (NF-99-HF, Alfa Laval). From the analysis of the results we can conclude that the optimal operating conditions are pressure of 20 bar and temperature of 35°C, allowing better separation performance: permeate flux of 28.3 L/m2·h and FFA retention of 70%.

2013 ◽  
Vol 378 ◽  
pp. 318-321 ◽  
Author(s):  
Ling Wang ◽  
Xue Feng Xiong ◽  
Zheng Fan ◽  
Guo Liang Zhang ◽  
Zhi Yang Wang

The nanofiltration (NF) membrane technology presented in this paper were used to treat the industrial electroplating effluent for reutilization, which contained hazardous heavy metal ions such as chromium and zinc. Two different kinds of nanofiltration membranes were applied in pilot scale installation following the conventional wastewater treatment system. The effects of different operating parameters on their separation performance were investigated in detail. Results showed that both two NF membranes held large permeate flux under relatively low operating pressures. The rejection rates of the monovalent ions were less than 50%, while for divalent ions they were more than 90%, including SO42-, Ca2+, Cr3+ and Zn2+. Higher permeate flux, lower operating pressure and distinguished ion selectivity of nanofiltration membranes exhibited a big potential for industrial application concerning the investment and operation cost .


2012 ◽  
Vol 522 ◽  
pp. 436-440
Author(s):  
Li Chao Ren ◽  
Mutellip Ahmat ◽  
Qiang Gao ◽  
Jing Luo

This research based on the vapor-liquid two-phases flow theory and methods, by using the CFD mix-multiphase flow model, the seal cavity vapor-liquid two-phases flow field for the bellows cartridge mechanical seal under such the high-temperature, high-pressure, high-speed as complex working conditions was numerically simulated and analyzed, then the characteristics of the complex three-dimensional flow field of seal cavity caused by the rotation of the sealing ring were obtained by the different position of the injected coolant, and the different cooling effects were contrasted, then the best cooling position were found by analysis. The researching results provide a theoretical basis for the structural optimization design of the high parameters bellows cartridge mechanical seal devices.


2020 ◽  
Vol 38 (8A) ◽  
pp. 1187-1199
Author(s):  
Qaed M. Ali ◽  
Mohammed M. Ezzalden

BLDC motors are characterized by electronic commutation, which is performed by using an electric three-phase inverter. The direct control system of the BLDC motor consists of double loops; including the inner-loop for current regulating and outer-loop for speed control. The operation of the current controller requires feedback of motor currents; the conventional current controller uses two current sensors on the ac side of the inverter to measure the currents of two phases, while the third current would be accordingly calculated. These two sensors should have the same characteristics, to achieve balanced current measurements. It should be noted that the sensitivity of these sensors changes with time. In the case of one sensor fails, both of them must be replaced. To overcome this problem, it is preferable to use one sensor instead of two. The proposed control system is based on a deadbeat predictive controller, which is used to regulate the DC current of the BLDC motor. Such a controller can be considered as digital controller mode, which has fast response, high precision and can be easily implemented with microprocessor. The proposed control system has been simulated using Matlab software, and the system is tested at a different operating condition such as low speed and high speed.


1996 ◽  
Vol 34 (5-6) ◽  
pp. 249-256 ◽  
Author(s):  
Hong-Ying Hu ◽  
Mamie Nozawa ◽  
Koichi Fujie ◽  
Tsuyoshi Makabe ◽  
Kohei Urano

The population dynamics of microbes in the biological wastewater treatment processes such as a submerged biofilter was investigated to obtain basic information to determine the optimal operating conditions. The effects of coexistence of biodegradable substances such as glucose and peptone on the acclimation of microbes in the biofilm to hard chemicals such as acrylonitrile (AN), which is poorly biodegradable and a volatile substance, was investigated on the basis of the respiratory quinone profile. Kinetic study of the removal of AN in the course of acclimation of microbes was investigated using a laboratory-scale submerged biofilter as well. It was ascertained that the acclimation of the microbes to AN was accelerated by coexistence of biodegradable substances, and the microbial phase after acclimation differed from those with the coexistence of glucose and peptone. The quinone profiles in the acclimation showed that Brevibacterium sp. and Pseudomonas aeruginosa, of which the predominant quinone of the respiratory chain is menaquinone-8(H2) and ubiquinone-9, respectively, multiplied selectively in the acclimation course without and with the coexistence of glucose and peptone, respectively. It was also made clear that there were few kinds and number of protozoa and metazoa in the biofilter treating the wastewater containing AN.


Energies ◽  
2021 ◽  
Vol 14 (3) ◽  
pp. 555
Author(s):  
Sangkyung Na ◽  
Sanghun Song ◽  
Seunghyuk Lee ◽  
Jehwan Lee ◽  
Hyun Kim ◽  
...  

In this study, evaporator optimization, via both experimental and simulation methods was conducted. To evaluate the evaporator performance, under the optimal system, the compressor operating time and the effects of oil on the refrigerator system were studied. If the temperature of the refrigerator chamber reaches the setting value, the compressor stops working and it leads to the temperature of the refrigerator chamber slowly increasing, due to the heat transfer to the ambient. When the refrigerator temperature is out of the setting range, the compressor works again, and the refrigerator repeats this process until the end of its life. These on/off period can be controlled through the compressor piston movement. To determine the optimal compressor operating conditions, experiments of monthly power consumption were conducted under various compressor working times and the lowest power consumption conditions was determined when the compressor worked continuously. Lubricating oil, the refrigerator system, using oil, also influenced the system performance. To evaluate the effect of oil, oil eliminated and oil systems were compared based on cooling capacity and power consumption. The cooling capacity of the oil eliminated system was 2.6% higher and the power consumption was 3.6% lower than that of the oil system. After determining the optimal operating conditions of the refrigerator system, visualization experiments and simulations were conducted to decide the optimal evaporator and the conventional evaporator size can be reduced by approximately 2.9%.


Materials ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1546
Author(s):  
Árpád Imre-Lucaci ◽  
Melinda Fogarasi ◽  
Florica Imre-Lucaci ◽  
Szabolcs Fogarasi

This paper presents a novel approach for the recovery of lead from waste cathode-ray tube (CRT) glass by applying a combined chemical-electrochemical process which allows the simultaneous recovery of Pb from waste CRT glass and electrochemical regeneration of the leaching agent. The optimal operating conditions were identified based on the influence of leaching agent concentration, recirculation flow rate and current density on the main technical performance indicators. The experimental results demonstrate that the process is the most efficient at 0.6 M acetic acid concentration, flow rate of 45 mL/min and current density of 4 mA/cm2. The mass balance data corresponding to the recycling of 10 kg/h waste CRT glass in the identified optimal operating conditions was used for the environmental assessment of the process. The General Effect Indices (GEIs), obtained through the Biwer Heinzle method for the input and output streams of the process, indicate that the developed recovery process not only achieve a complete recovery of lead but it is eco-friendly as well.


Molecules ◽  
2021 ◽  
Vol 26 (7) ◽  
pp. 2003
Author(s):  
Paul Muñoz ◽  
Karla Pérez ◽  
Alfredo Cassano ◽  
René Ruby-Figueroa

Wastewaters and by-products generated in the winemaking process are important and inexpensive sources of value-added compounds that can be potentially reused for the development of new products of commercial interest (i.e., functional foods). This research was undertaken in order to evaluate the potential of nanofiltration (NF) membranes in the recovery of anthocyanins and monosaccharides from a clarified Carménère grape marc obtained through a combination of ultrasound-assisted extraction and microfiltration. Three different flat-sheet nanofiltration (NF) membranes, covering the range of molecular weight cut-off (MWCO) from 150 to 800 Da, were evaluated for their productivity as well as for their rejection towards anthocyanins (malvidin-3-O-glucoside, malvidin 3-(acetyl)-glucoside, and malvidin 3-(coumaroyl)-glucoside) and sugars (glucose and fructose) in selected operating conditions. The selected membranes showed differences in their performance in terms of permeate flux and rejection of target compounds. The NFX membrane, with the lowest MWCO (150–300 Da), showed a lower flux decay in comparison to the other investigated membranes. All the membranes showed rejection higher than 99.42% for the quantified anthocyanins. Regarding sugars rejection, the NFX membrane showed the highest rejection for glucose and fructose (100 and 92.60%, respectively), whereas the NFW membrane (MWCO 300–500 Da) was the one with the lowest rejection for these compounds (80.57 and 71.62%, respectively). As a general trend, the tested membranes did not show a preferential rejection of anthocyanins over sugars. Therefore, all tested membranes were suitable for concentration purposes.


2013 ◽  
Vol 11 (2) ◽  
Author(s):  
David Ouellette ◽  
Cynthia Ann Cruickshank ◽  
Edgar Matida

The performance of a new methanol fuel cell that utilizes a liquid formic acid electrolyte, named the formic acid electrolyte-direct methanol fuel cell (FAE-DMFC) is experimentally investigated. This fuel cell type has the capability of recycling/washing away methanol, without the need of methanol-electrolyte separation. Three fuel cell configurations were examined: a flowing electrolyte and two circulating electrolyte configurations. From these three configurations, the flowing electrolyte and the circulating electrolyte, with the electrolyte outlet routed to the anode inlet, provided the most stable power output, where minimal decay in performance and less than 3% and 5.6% variation in power output were observed in the respective configurations. The flowing electrolyte configuration also yielded the greatest power output by as much as 34%. Furthermore, for the flowing electrolyte configuration, several key operating conditions were experimentally tested to determine the optimal operating points. It was found that an inlet concentration of 2.2 M methanol and 6.5 M formic acid, as along with a cell temperature of 52.8 °C provided the best performance. Since this fuel cell has a low optimal operating temperature, this fuel cell has potential applications for handheld portable devices.


Sign in / Sign up

Export Citation Format

Share Document