scholarly journals Thermal Comfort for Urban Parks in Subtropics: Understanding Visitor’s Perceptions, Behavior and Attendance

2013 ◽  
Vol 2013 ◽  
pp. 1-8 ◽  
Author(s):  
Chuang-Hung Lin ◽  
Tzu-Ping Lin ◽  
Ruey-Lung Hwang

The paper is an effort toward thermal comfort assessment for urban parks under the climatic conditions of Taiwan to help architects achieve better climatic design. Field interviews, observations, and micrometeorological measurements were conducted in this study. The WBGT was used as the thermophysiological index to investigate the effects of thermal conditions on visitor’s thermal perception and adaptive behavior in outdoor urban spaces. In this study, behavioral adaptations used by visitors as a means of achieving comfort were evaluated. Observational results showed that the overall attendance was influenced by sun and thermal conditions. There was a robust relationship between thermal sensation votes, as well as thermal acceptability, and thermal environment, in terms of WBGT. The upper and lower limits of 80% acceptability are 26°C WBGT and 20°C WBGT, respectively.

2021 ◽  
pp. 1420326X2110345
Author(s):  
Marika Vellei ◽  
William O’Brien ◽  
Simon Martinez ◽  
Jérôme Le Dréau

Recent research suggests that a time-varying indoor thermal environment can lead to energy savings and contribute to boost buildings' energy flexibility. However, thermal comfort standardization has so far considered thermal comfort criteria as constant throughout the day. In general, very little attention has been given to the ‘ time of day' variable in the context of thermal comfort research. In this paper, we show some evidence of a time-varying thermal perception by using: (1) data from about 10,000 connected Canadian thermostats made available as part of the ‘ Donate Your Data' dataset and (2) about 22,000 samples of complete (objective + ‘ right-here-right-now' subjective) thermal comfort field data from the ASHRAE I and SCATs datasets. We observe that occupants prefer colder thermal conditions at 14:00 and progressively warmer ones in the rest of the day, indistinctively in the morning and evening. Neutral temperature differences between 08:00 and 14:00 and 14:00 and 20:00 are estimated to be of the order of 2°C. We hypothesize that the human circadian rhythm is the cause of this difference. Nevertheless, the results of this study are only based on observational data. Thermal comfort experiments in controlled environmental chambers are required to confirm these findings and to better elucidate the effects of light and circadian timing and their interaction on thermal perception.


1987 ◽  
Vol 1 (2) ◽  
pp. 74-77 ◽  
Author(s):  
S C Foo ◽  
WO Phoon

Two hundred and eighty-five Office workers were surveyed and the micro-climatic conditions in which they worked were measured to evaluate their preferred temperature. About 78% of workers considered the natural tropical climate uncomfortable. However, 76% to 87% of workers in airconditioned Offices approved of their thermal environment if its temperature ranged from 21°C to 27°C. Many workers who felt that the temperature produced a neutral thermal sensation in the body as a whole, tended to complain that their heads were too warm and at the same time their limbs too cool. About 60% of workers in airconditioned Offices were exposed to an air temperature of less than 24°C. Present data suggest that an air temperature of 27°C would be comfortable for more than 80% of workers.


2019 ◽  
Vol 11 (14) ◽  
pp. 3948 ◽  
Author(s):  
Miguel Ángel Campano ◽  
Samuel Domínguez-Amarillo ◽  
Jesica Fernández-Agüera ◽  
Juan José Sendra

A comprehensive assessment of indoor environmental conditions is performed on a representative sample of classrooms in schools across southern Spain (Mediterranean climate) to evaluate the thermal comfort level, thermal perception and preference, and the relationship with HVAC systems, with a comparison of seasons and personal clothing. Almost fifty classrooms were studied and around one thousand pool-surveys distributed among their occupants, aged 12 to 17. These measurements were performed during spring, autumn, and winter, considered the most representative periods of use for schools. A new proposed protocol has been developed for the collection and subsequent analysis of data, applying thermal comfort indicators and using the most frequent predictive models, rational (RTC) and adaptive (ATC), for comparison. Cooling is not provided in any of the rooms and natural ventilation is found in most of the spaces during midseasons. Despite the existence of a general heating service in almost all classrooms in the cold period, the use of mechanical ventilation is limited. Heating did not usually provide standard set-point temperatures. However, this did not lead to widespread complaints, as occupants perceive the thermal environment as neutral—varying greatly between users—and show a preference for slightly colder environments. Comparison of these thermal comfort votes and the thermal comfort indicators used showed a better fit of thermal preference over thermal sensation and more reliable results when using regional ATC indicators than the ASHRAE adaptive model. This highlights the significance of inhabitants’ actual thermal perception. These findings provide useful insight for a more accurate design of this type of building, as well as a suitable tool for the improvement of existing spaces, improving the conditions for both comfort and wellbeing in these spaces, as well as providing a better fit of energy use for actual comfort conditions.


2014 ◽  
Vol 672-674 ◽  
pp. 1665-1669 ◽  
Author(s):  
Iman Asadi ◽  
Ibrahim Hussein ◽  
Kumaran Palanisamy

Field study was carried out on the thermal conditions and thermal comfort of occupants in air conditioned buildings in Malaysia. The study was carried out in 10 staff offices and 6 student study areas of Universiti Tenaga Nasional (UNITEN) during October and November 2013, collecting a full set of objective physical measurements and subjective assessments through questionnaires. The measured environmental parameters were air temperature, relative humidity and air velocity. The subjective responses concern the judgment of the occupants about the thermal environment at the moment of measurements. The obtained results showed that most places are in acceptable and comfort zone according to Fanger’s predicted mean vote (PMV) model. The neutral air temperature obtained through linear regression analysis of thermal sensation vote (TSV) is 23.9°C for UNITEN. The result of this study demonstrates that the acceptability of thermal comfort among UNITEN occupant is about 78 %.


2019 ◽  
Vol 29 (6) ◽  
pp. 851-859 ◽  
Author(s):  
Michael Fabozzi ◽  
Alessandro Dama

Maintaining a satisfactory thermal environment is of primary importance, especially when the goal is to maximize learning such as in schools or universities. This paper presents a field study conducted in Milan during summer 2017 in 16 classrooms of Politecnico di Milano, including both naturally ventilated (NV) and air-conditioned (AC) environments. This study asked 985 students to report their thermal perception and their responses were evaluated according to the measured thermal comfort parameters to assess the prediction as given by Fanger and adaptive models, according to ANSI/ASHRAE 55-2017 and EN 15251:2007 standards. Furthermore, an analysis regarding potential effects of gender in comfort perception was performed. The results confirmed the fitness of Fanger’s model for the prediction of occupants’ thermal sensations in AC classrooms with a reasonable accuracy. In NV classrooms, the Adaptive model was proven to be suitable for predicting students’ comfort zone according to ASHRAE 55 Standard, while the adaptive comfort temperatures recommended by EN 15251 were not acceptable for a large number of students. No significant differences in thermal comfort perception between genders have been observed, except for two NV classrooms in which females’ thermal sensation votes had resulted closer to neutrality in comparison to males, who expressed a warmer thermal sensation.


2017 ◽  
Vol 21 (3) ◽  
pp. 1409-1418 ◽  
Author(s):  
Laszlo Kajtar ◽  
Jozsef Nyers ◽  
Janos Szabo ◽  
Laszlo Ketskemety ◽  
Levente Herczeg ◽  
...  

Thermal comfort sensation can be predicted in the most exact way based on Fanger?s predicted mean vote (PMV) model. This evaluation method takes all the six influencing factors into consideration: air temperature and humidity, air velocity, mean radiant temperature of surrounding surfaces, clothing insulation, and occupants? activities. Fanger?s PMV method was developed for temperate climate and European people, with the participation of university students as subjects. Many researchers had investigated its validity in different geographic locations (i. e. climatic conditions, people) and under non-laboratory circumstances. The results were summarised by van Hoof which had been published in the scientific references. The articles gave us the idea to elaborate the former measurement results. During the last decades thermal comfort was evaluated by our research team using subjective scientific questionnaires and applying the objective Fanger?s model in several office buildings in Hungary. The relation between the PMV and actual mean vote values were analysed based on these results. Investigations were carried out under steady-state conditions in winter time. We performed objective thermal comfort evaluations based on instrumental measurements using the PMV theory. Parallel to this we assessed the subjective thermal sensation using scientific questionnaires. The mathematical relationship between the actual mean vote and PMV was defined according to the evaluated thermal environment: AMV = PMV + 0.275, (arg. ?1.7 ? PMV ? +0.5).


Buildings ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 326
Author(s):  
Wiwik Budiawan ◽  
Kazuyo Tsuzuki

Thermal comfort is crucial in satisfaction and maintaining quality sleep for occupants. In this study, we investigated the comfort temperature in the bedroom at night and sleep quality for Indonesian students during summer and winter. Eighteen male Indonesian students aged 29 ± 4 years participated in this study. The participants had stayed in Japan for about six months. We evaluated the sleep parameters using actigraphy performed during summer and winter. All participants completed the survey regarding thermal sensation, physical conditions, and subjective sleepiness before sleep. The temperature and relative humidity of participants’ bedrooms were also measured. We found that the duration on the bed during winter was significantly longer than that during summer. However, sleeping efficiency during winter was significantly worse than that during summer. The bedroom temperature of the participants was in the range of comfort temperature in Indonesia. With the average bedroom air temperature of 22.2 °C, most of the participants still preferred “warm” and felt “slightly comfortable” during winter. The average comfort temperature each season calculated using the Griffiths method was 28.1 °C during summer and 23.5 °C during winter. In conclusion, differences in adaptive action affect bedroom thermal conditions. Furthermore, habits encourage the sleep performance of Indonesian students.


2021 ◽  
Author(s):  
Christopher L. K. Wang

As sleep is unconscious, the traditional definition of thermal comfort with conscious judgment does not apply. In this thesis sleep thermal comfort is defined as the thermal condition which enables sleep to most efficiently rejuvenate the body and mind. A comfort model was developed to stimulate the respective thermal environment required to achieve the desired body thermal conditions and a new infrared sphere method was developed to measure mean radiant temperature. Existing heating conditions according to building code conditions during sleeping hours was calculated to likely overheat a sleeping person and allowed energy saving potential by reducing nighttime heating set points. Experimenting with existing radiantly and forced air heated residential buildings, it was confirmed that thermal environment was too hot for comfortable sleep and that the infrared sphere method shows promise. With the site data, potential energy savings were calculated and around 10% of energy consumption reduction may be achieved during peak heating.


Technologies ◽  
2021 ◽  
Vol 9 (4) ◽  
pp. 90
Author(s):  
Siliang Lu ◽  
Erica Cochran Hameen

Heating, ventilation and air-conditioning (HVAC) systems play a key role in shaping office environments. However, open-plan office buildings nowadays are also faced with problems like unnecessary energy waste and an unsatisfactory shared indoor thermal environment. Therefore, it is significant to develop a new paradigm of an HVAC system framework so that everyone could work under their preferred thermal environment and the system can achieve higher energy efficiency such as task ambient conditioning system (TAC). However, current task conditioning systems are not responsive to personal thermal comfort dynamically. Hence, this research aims to develop a dynamic task conditioning system featuring personal thermal comfort models with machine learning and the wireless non-intrusive sensing system. In order to evaluate the proposed task conditioning system performance, a field study was conducted in a shared office space in Shanghai from July to August. As a result, personal thermal comfort models with indoor air temperature, relative humidity and cheek (side face) skin temperature have better performances than baseline models with indoor air temperature only. Moreover, compared to personal thermal satisfaction predictions, 90% of subjects have better performances in thermal sensation predictions. Therefore, personal thermal comfort models could be further implemented into the task conditioning control of TAC systems.


2019 ◽  
Vol 41 (5) ◽  
pp. 561-585 ◽  
Author(s):  
Fangliang Zhong ◽  
John K Calautit ◽  
Ben R Hughes

After winning the bid of the FIFA’s World Cup 2022, Qatar is facing the greatest challenges in terms of minimizing substantial energy consumptions for air-conditioning of stadiums and maintaining aero-thermal comfort for both players and spectators inside stadiums. This paper presents the results of temperature distributions and wind environment of the original stadium under the hot-humid climate and improvements on them for optimized scenarios of cooling jets. A combined computational fluid dynamics and building energy simulation approach was used to analyse the cooling performance and energy consumption per match of cooling air jets for 10 scenarios with different supply velocities, supply temperatures and locations of jets. The optimal scenario is to employ vertical jets above the upper tiers at supply temperature of 20°C and velocities of 2–12 m/s, integrated with horizontal jets of the same temperature at the lower tiers with 4 m/s and around the pitch with 7 m/s. This scenario can maintain the spectator tiers at an average temperature of 22°C and reduce the maximum predicted percentage of dissatisfied of thermal comfort from the original 100% to 63% for the pitch and 19% for the tiers, respectively. In terms of the energy consumption for the air-conditioning system per match, compared with one of the 2010 South Africa World Cup stadiums Royal Bafokeng stadium which consumed approximately 22.8 MWh energy for air-conditioning in winter (highest outdoor temperature 24.4°C), the maximum energy consumption of the optimal scenario in November (highest outdoor temperature 34.2°C) can reach 108 MWh. In addition, the spectator zones with scenario 8 have the potential to be resilient to the seasonal change of outdoor temperature if slight modifications of the supply velocities and precise temperature control on the spectator zones are applied. Moreover, the configurations presented in this paper can be used as a foundation of jets arrangement for future stadium retrofits in the hot climates. Practical application: This study assesses the aero-thermal conditions of a case study stadium under the hot climate of Qatar and explores the potential of applying cooling jets with different supply velocities, supply temperatures and their locations on the enhancement of both thermal and wind environment of spectator tiers and pitch. The assessment of the original stadium indicates that the ascending curved roof structure impedes the fresh air entering into the stadium and results in an asymmetric temperature distribution on the spectator tiers. The optimized design suggests a combination of vertical jets under the roof and both three arrays of horizontal jets at lower tiers and around pitch for future stadium optimizations in hot climates. It also recommends enhancing the thermal conditions on the pitch by optimizing the velocity of horizontal jets around the pitch. Moreover, the future design of the exact stadiums to be resilient to the seasonal changing outdoor temperature can be implemented based on scenario 8.