scholarly journals Buoyancy Effect of Ionic Vacancy on the Change of the Partial Molar Volume in Ferricyanide-Ferrocyanide Redox Reaction under a Vertical Gravity Field

2013 ◽  
Vol 2013 ◽  
pp. 1-12 ◽  
Author(s):  
Yoshinobu Oshikiri ◽  
Makoto Miura ◽  
Ryoichi Aogaki

With a gravity electrode (GE) in a vertical gravity field, the buoyancy effect of ionic vacancy on the change of the partial molar volume in the redox reaction between ferricyanide (FERRI) and ferrocyanide (FERRO) ions was examined. The buoyancy force of ionic vacancy takes a positive or negative value, depending on whether the rate-determining step is the production or extinction of the vacancy. Though the upward convection over an upward electrode in the FERRO ion oxidation suggests the contribution of the positive buoyancy force arising from the vacancy production, the partial molar volume of the vacancy was not measured. On the other hand, for the downward convection under a downward electrode in the FERRI ion reduction, it was not completely but partly measured by the contribution of the negative buoyancy force from the vacancy extinction. Since the lifetime of the vacancy is decreased by the collision between ionic vacancies during the convection, the former result was ascribed to the shortened lifetime due to the increasing collision efficiency in the enhanced upward convection over an upward electrode, whereas the latter was thought to arise from the elongated lifetime due to the decreasing collision efficiency by the stagnation under the downward electrode.

Author(s):  
Da Liu ◽  
Fujun Gan ◽  
Chaozhu Zhang ◽  
Hanyang Gu

Experiments of heat transfer at low flow rate are performed in a 5×5 square arrayed rod bundles. The diameter of the rod is 10mm with a pitch of 13.3mm, length of the test section is about 3 meters. Inlet Reynold number ranges from 2000 to 30000, Bo * ranges from 4×10−6 to 5×10−3. The rods are heated using a DC power, the heat flux ranges from 30 to 300 kW/m2. The experiment is aimed to investigate the buoyancy effect of mixed convection in rod bundles. The experimental data shows that similar with mixed convection in circular channels, buoyancy force has great effect on heat transfer at mixed convection regime in rod bundles. But the buoyancy effect appears at higher Bo* conditions. The spacer effect have also been investigated at both turbulent forced convection regime and mixed convection regime. The reconstruction of heat transfer downstream of spacers is different at different flow regimes, a reasonable explanation was provided.


1989 ◽  
Vol 27 (11) ◽  
pp. 2243-2250 ◽  
Author(s):  
Yoshinori Kamiya ◽  
Yasutoshi Naito ◽  
Keishin Mizoguchi

2001 ◽  
Vol 142 (2) ◽  
pp. 235-243 ◽  
Author(s):  
Ali M. Bouhifd ◽  
Alan Whittington ◽  
Pascal Richet

1983 ◽  
Vol 48 (8) ◽  
pp. 2327-2334
Author(s):  
Otakar Söhnel ◽  
Petr Novotný ◽  
Zdeněk Šolc

Two methods are given for assessment of density of binary aqueous solutions of electrolytes; one is based on partial molar volume of the dissolved electrolyte at infinite dilution, and the other is based on additivity of apparent molar volumes at a given concentration. The density estimates of aqueous solutions by means of the two methods are compared with experimental values for some electrolytes of the type 1-1 to 4 and 2-2. In all cases the estimates agree with experimental densities up to concentrations of the saturated solutions.


Sign in / Sign up

Export Citation Format

Share Document