scholarly journals Flame Atomic Absorption Spectrometric Determination of Trace Amounts of Silver after Solid-Phase Extraction with 2-Mercaptobenzothiazole Immobilized on Microcrystalline Naphthalene

2013 ◽  
Vol 2013 ◽  
pp. 1-6 ◽  
Author(s):  
Farid Shakerian ◽  
Ali Mohammad Haji Shabani ◽  
Shayessteh Dadfarnia ◽  
Mahdieh Shabani

A simple and sensitive solid-phase extraction (SPE) procedure combined with flame atomic absorption spectrometry (FAAS) was designed for the extraction and determination of trace amounts of silver. A column of immobilized 2-mercaptobenzothiazole (MBT) on microcrystalline naphthalene was used as the sorbent. Silver was quantitatively retained on the column in the pH range of 0.5–6.0. After extraction, the solid mass consisting of silver complex and naphthalene was dissolved out of the column with 5.0 mL of dimethylformamide, and the analyte was determined by flame atomic absorption spectrometry (FAAS). Under the optimum experimental conditions, the adsorption capacity was found to be 1.18 mg of silver per gram of the sorbent. A sample volume of 800 mL resulted in a preconcentration factor of 160. The relative standard deviation obtained for ten replicate determinations at a concentration of 0.8 µg L−1was 1.4%, and the limit of detection was 0.02 µg L−1. The method was successfully applied to the determination of silver in radiology film, waste water, and natural water samples. The accuracy was examined by recovery experiments, independent analysis by electrothermal atomic absorption spectrometry, and analysis of two certified reference materials.

2011 ◽  
Vol 2011 ◽  
pp. 1-6 ◽  
Author(s):  
Vanessa N. Alves ◽  
Simone S. O. Borges ◽  
Waldomiro B. Neto ◽  
Nívia M. M. Coelho

In this study, a method for the determination of low concentrations of lead in beer samples using solid-phase extraction with a flow injection analysis system and detection by flame atomic absorption spectrometry (FAAS) was developed.Moringa oleiferaseeds were used as a biosorbent material. Chemical and flow variables of the online preconcentration system, such as sample pH, preconcentration flow rate, eluent flow rate, eluent concentration, particle size, and sorbent mass, were studied. The optimum extraction conditions were obtained using a sample pH of 6.0, sample flow rate of 6.0 mL min−1, 63.0 mg of sorbent mass, and 2.0 mol L−1HNO3at a flow rate of 2.0 mL min−1as the eluent. With the optimized conditions, the preconcentration factor, precision, detection limit, consumption index, and sample throughput were estimated as 93, 0.3% (10.0 μg L−1,n=7), 7.5 μg L−1, 0.11 mL, and 23 samples per hour, respectively. The method developed was successfully applied to beer samples and recovery tests, with recovery ranging from 80% to 100%.


2014 ◽  
Vol 29 (9) ◽  
pp. 1692-1697 ◽  
Author(s):  
Jianping Zou ◽  
Xiaoguo Ma ◽  
Yongfeng Dang ◽  
Yuan Chen

A sensitive and reliable method for trace determination of Cd(ii) and Cu(ii) based on solid-phase extraction using a novel sorbent coupled with flame atomic absorption spectrometry.