scholarly journals Implementation of Control System for Hydrokinetic Energy Converter

2013 ◽  
Vol 2013 ◽  
pp. 1-10 ◽  
Author(s):  
Katarina Yuen ◽  
Senad Apelfröjd ◽  
Mats Leijon

At Uppsala University, a research group is investigating a system for converting the power in freely flowing water using a vertical-axis turbine directly connected to a permanent magnet generator. An experimental setup comprising a turbine, a generator, and a control system has been constructed and will be deployed in the Dalälven river in the town of Söderfors in Sweden. The design, construction, simulations, and laboratory tests of the control system are presented in this paper. The control system includes a startup sequence for the turbine and load control. These functions have performed satisfactorily in laboratory tests. Simulations of the system show that the power output is not maximized at the same tip-speed ratio as that which maximizes the turbine power capture.

2020 ◽  
Vol 170 ◽  
pp. 01016
Author(s):  
Zaid Hammoudi ◽  
Ikram El Abbassi ◽  
Rafik Absi ◽  
A.-Moumen Darcherif

In last years, interest in hydrokinetic energy conversion (HEC) technology has grown. However, HEC technology requires advancements to become successful for practical in-situ conditions. In this study we investigated the Darrieus type vertical axis hydrokinetic turbines (HKT). Simulations are carried out using commercial CFD package to study the hydrodynamic behavior of a three bladed turbine. Two HKT with same solidity equal to 0.17 were considered, a 1st with symmetric-NACA0018 blade hydrofoils and a 2nd with cambered-NACA4415 blades. Our simulations show a shift in instantaneous torque coefficients for two different tip-speed ratio (TSR) values. For TSR = 1, the 2nd HKT has a delay compared to the 1st HKT, while for TSR = 2 it has a lead. NACA0018 provides highest troque coefficients. For a hydrofarm use, it is important to consider the interactions between hydrokinetic turbines. We investigated the effect of streamwise distance on performance of a Darrieus turbine. A distance of about 11 times the diameter of HKT along the streamwise direction seems essential.


2008 ◽  
Vol 32 (2) ◽  
pp. 143-161 ◽  
Author(s):  
Tetsuya Wakui ◽  
Ryohei Yokoyama

A suitable load control method for constant tip speed ratio operation of a stand-alone system using a vertical axis wind turbine with self-starting capability is discussed. The system with a straight-wing-type turbine is mainly operated at a constant tip speed ratio. Two types of load control methods are considered: Method-1, where the load torque is controlled in proportion to the square of the rotational speed, and Method-2, which adopts feedback control of the rotational speed in response to the measured wind speed. In this second report on a suitable load control method, the influence of the measurement error of the inflow wind speed is particularly focused on. The computational results obtained using the dynamic simulation model show that Method-1, which is not affected by the measurement error and has a fine smoothing effect of the output fluctuation, is the more suitable load control method.


2012 ◽  
Vol 189 ◽  
pp. 448-452
Author(s):  
Yan Jun Chen ◽  
Guo Qing Wu ◽  
Yang Cao ◽  
Dian Gui Huang ◽  
Qin Wang ◽  
...  

Numerical studies are conducted to research the performance of a kind of lift-drag type vertical axis wind turbine (VAWT) affected by solidity with the CFD method. Moving mesh technique is used to construct the model. The Spalart-Allmaras one equation turbulent model and the implicit coupled algorithm based on pressure are selected to solve the transient equations. In this research, how the tip speed ratio and the solidity of blade affect the power coefficient (Cp) of the small H-VAWT is analyzed. The results indicate that Cp curves exhibit approximate parabolic form with its maximum in the middle range of tip speed ratio. The two-blade wind turbine has the lowest Cp while the three-blade one is more powerful and the four-blade one brings the highest power. With the certain number of blades, there is a best chord length, and too long or too short chord length may reduce the Cp.


Author(s):  
WAHYU AULIA NURWICAKSANA ◽  
BUDHY SETIAWAN ◽  
IKA NOER SYAMSIANA ◽  
SEPTYANA RISKITASARI

ABSTRAKVAWT (Vertical Axis Wind Turbine) tipe Darrieus NACA0015 merupakan salah satu model dari turbin angin yang bekerja dengan menggunakan angin sebagai sumber penggerak. Namun dari hasil pengamatan, kecepatan angin yang ada tidak konstan setiap saat. Sehingga dari permasalahan ini perlu suatu kontrol yaitu dengan mengendalikan sudut kerja blade VAWT yang dikenal dengan kontrol angle of attack (AoA). Prinsip kerja kontrol AoA yaitu sudut blade diatur agar VAWT bekerja secara optimum dan dapat meningkatkan efisiensi. Metode kontrol AoA menggunakan PID (Proportional–Integral–Derivative) dengan memberikan nilai trial and error pada Kp, Ki, Kd. VAWT ini menggunakan konstanta TSR (Tip Speed Ratio) yaitu 4. Hasil dari penelitian ini yaitu daya yang dihasilkan VAWT dengan kontrol AoA mendapatkan rata-rata efisiensi sebesar 5.16%, sedangkan VAWT tanpa kontrol mendapatkan efisiensi sebesar 3.49%. Sehingga dapat disimpulkan bahwa dengan kontrol AoA, rata-rata efisiensi dayanya naik sebesar 1.67% dari yang tanpa kontrol.Kata Kunci: Kontrol Angle of Attack (AoA), VAWT, TSR, Efisiensi ABSTRACTVAWT (Vertical Axis Wind Turbine) type Darrieus NACA0015 is one model of a wind turbine that works by using wind as a source of propulsion. Conditions from observations, wind speeds that are not constant every time. So from this problem needs control VAWT by controlling the working angle of the VAWT blade is the angle of attack control (AoA). The principle AoA control is that the blade angle adjusted so that the VAWT works optimally and can improve the efficiency. AoA control method uses PID (Proportional-Integral-Derivative) by providing trial and error values for Kp, Ki, Kd. VAWT uses TSR (Tip Speed Ratio) constant which is 4. The results of this research, VAWT with AoA control get an average efficiency of 5.16%, while without control gets an average efficiency of 3.49%. So it can be concluded that with AoA control, the average power efficiency increases by 1.67% from those without control.Keywords: Angle of Attack (AoA) Control, VAWT, TSR, Efficiency


Author(s):  
Ali Bakhshandeh Rostami ◽  
Antonio Carlos Fernandes

The present paper explores experimentally the performance of two types of hinged plates which rotate about vertical axis when submitted to uniform current. A flat plate configuration and also a flapped plate (say, S shape) configuration have been investigated. The Vertical axis Auto rotation Current Turbine (VAACT) is one degree of freedom system (free to rotate in yaw direction). It is shown that a high efficiency for S shape type can be obtained of the order of 30 percent while flat blade type reaches approximately to 7 percent. Upper limit of tip speed ratio for flat blade type has been expanded approximately 0.9 whereas S shape approaches 1.3.


Author(s):  
Akshay Pendharkar ◽  
Ryan McGowan ◽  
Kevin Morillas ◽  
Mark Pinder ◽  
Narayanan Komerath

Author(s):  
Dygku. Asmanissa Awg. Osman ◽  
Norzanah Rosmin ◽  
Nor Shahida Hasan ◽  
Baharruddin Ishak ◽  
Aede Hatib Mustaamal@Jamal ◽  
...  

The air streams from the outlet of an air compressor can be used to generate electricity. For instance, if a micro-sized Vertical-Axis Wind-Turbine (VAWT) is installed towards the airflow, some amount of electricity can be generated before being stored in a battery bank. The research’s objectives are to design, fabricate and analyze the performance of Helical Savonius VAWT blade rotors, which is tested with and without using a wind concentrator. The Helical Savonius VAWT is tested at 0 cm without the concentrator, whereas the blade rotor is tested at concave-blade position when using the concentrator. The blade and the wind concentrator designs were based on the dimensions and the constant airflow of the air compressor. The findings suggested that the blade produced its best performance when tested using wind concentrator at concave-blade position in terms of angular speed (<em>ω</em>), tip speed ratio (<em>TSR</em>) and the generated electrical power (<em>P</em><em><sub>E</sub></em>). The findings concluded that the addition of wind concentrator increases the airflow which then provided better performances on the blades.


2020 ◽  
Vol 33 ◽  
pp. 4719-4722
Author(s):  
E. Leelakrishnan ◽  
M. Sunil Kumar ◽  
S. David Selvaraj ◽  
N. Sundara Vignesh ◽  
T.S. Abhesheka Raja

2015 ◽  
Vol 137 (5) ◽  
Author(s):  
Vincenzo Dossena ◽  
Giacomo Persico ◽  
Berardo Paradiso ◽  
Lorenzo Battisti ◽  
Sergio Dell'Anna ◽  
...  

This paper presents the results of a wide experimental study on an H-type vertical axis wind turbine (VAWT) carried out at the Politecnico di Milano. The experiments were carried out in a large-scale wind tunnel, where wind turbines for microgeneration can be tested in real-scale conditions. Integral torque and thrust measurements were performed, as well as detailed aerodynamic measurements to characterize the flow field generated by the turbine downstream of the rotor. The machine was tested in both a confined (closed chamber) and unconfined (open chamber) environment, to highlight the effect of wind tunnel blockage on the aerodynamics and performance of the VAWT under investigation. The experimental results, compared with the blockage correlations presently available, suggest that specific correction models should be developed for VAWTs. The experimental thrust and power curves of the turbine, derived from integral measurements, exhibit the expected trends with a peak power coefficient of about 0.28 at tip-speed ratio equal to 2.5. Flow measurements, performed in three conditions for tip speed ratio equal to 1.5, 2.5, and 3.5, show the fully three-dimensional character of the wake, especially in the tip region where a nonsymmetrical wake and tip vortex are found. The unsteady evolution of the velocity and turbulence fields further highlights the effect of aerodynamic loading on the wake unsteadiness, showing the time-dependent nature of the tip vortex and the onset of dynamic stall for tip speed ratio lower than 2.


Sign in / Sign up

Export Citation Format

Share Document