scholarly journals Continuous Monitoring of Water Quality Using Portable and Low-Cost Approaches

2013 ◽  
Vol 9 (6) ◽  
pp. 249598 ◽  
Author(s):  
Gurkan Tuna ◽  
Orhan Arkoc ◽  
Kayhan Gulez
2021 ◽  
Author(s):  
Elias Dimitriou ◽  
Georgios Poulis ◽  
Anastasios Papadopoulos

<p>Good water quality status in rivers and lakes is vital for both human well-being and biodiversity conservation and requires efficient monitoring and restoration strategies. This is reflected in an increasing number of International and National legislations which enforce water resources management and monitoring at a basin scale.</p><p>For this purpose, state-of-the-art monitoring schemes have been developed by using low-cost, technologically advanced sensors and Internet of Things (IoT) infrastructure. Remote sensing offers also a good water monitoring alternative but is more appropriate for medium to large water bodies with less dynamic character in comparison to small scale, temporary rivers.</p><p>Recent technological advances in sensors technology, energy supply, telecommunication protocols and data handling, facilitate the use of automated monitoring stations, but still, deployment of extended networks with readily available data remains far from common practice. Installation and operational costs for the development of such monitoring networks are among the most commonly faced challenges.</p><p>The main aim of this effort is to present the development of a network of automatic monitoring stations that measure in near real time water level and physicochemical parameters in several Greek rivers. This infrastructure has been developed under the project “Open ELIoT” (Open Internet of Things infrastructure for online environmental services - https://www.openeliot.com/en/), which was funded by the Greek National Structural Funds. It includes a low cost and easy to produce hardware node, coupled with commercial sensors of industrial specifications, as well as an IoT data platform, elaborating and presenting data, based on open technologies.</p><p>During its initial operation phase, the system has been deployed in sites with different hydrological regimes and various pressures to water quality, including (a) an urban Mediterranean stream (Pikrodafni stream), and (b) the urban part of a continental river running through an agricultural area (Lithaios stream).</p><p>Preliminary data on the continuous monitoring of sites (a) and (b) are presented here, reflecting the differences in pressures to the respective water bodies. Pikrodafni stream which is located close to the center of Athens – Greece and receives a lot of pressure from urban waste, illustrates Dissolved Oxygen (DO) concentration with a heavily skewed distribution towards low values (mean value: 2.15 mg/l and median: 0.93 mg/l). On the contrary, in Lithaios stream, which is more affected by agricultural runoff, dissolved oxygen data approach a normal distribution (mean value: 6.93 mg/l and median: 7.03 mg/l). The 25<sup>th</sup> and 75<sup>th</sup> percentiles in Pikrodafni stream are: 0.1 mg/l and 3.47 mg/l respectively while in Lithaios stream are: 5.6 mg/l and 8.45 mg/l. The average water temperature is similar to both streams (18.8 oC in Pikrodafni and 16.2 oC in Lithaios). Therefore, the significant differences in DO concentrations between the two streams indicate the need for continuous monitoring of data that facilitates the identification of pressures and enables stakeholders to respond to pollution events in time.</p>


Sensors ◽  
2019 ◽  
Vol 19 (14) ◽  
pp. 3039 ◽  
Author(s):  
David Gillett ◽  
Alan Marchiori

Turbidity describes the cloudiness, or clarity, of a liquid. It is a principal indicator of water quality, sensitive to any suspended solids present. Prior work has identified the lack of low-cost turbidity monitoring as a significant hurdle to overcome to improve water quality in many domains, especially in the developing world. Low-cost hand-held benchtop meters have been proposed. This work adapts and verifies the technology for continuous monitoring. Lab tests show the low-cost continuous monitor can achieve 1 nephelometric turbidity unit (NTU) accuracy in the range 0–100 NTU and costs approximately 64 USD in components to construct. This level of accuracy yields useful and actionable data about water quality and may be sufficient in certain applications where cost is a primary constraint. A 38-day continuous monitoring trial, including a step change in turbidity, showed promising results with a median error of 0.45 and 1.40 NTU for two different monitors. However, some noise was present in the readings resulting in a standard deviation of 1.90 and 6.55 NTU, respectively. The cause was primarily attributed to ambient light and bubbles in the piping. By controlling these noise sources, we believe the low-cost continuous turbidity monitor could be a useful tool in multiple domains.


Micromachines ◽  
2020 ◽  
Vol 11 (5) ◽  
pp. 474 ◽  
Author(s):  
Bei Wang ◽  
Manuel Baeuscher ◽  
Xiaodong Hu ◽  
Markus Woehrmann ◽  
Katharina Becker ◽  
...  

A novel capacitive sensor for measuring the water-level and monitoring the water quality has been developed in this work by using an enhanced screen printing technology. A commonly used environment-friendly conductive polymer poly(3,4-ethylenedioxythiophene):poly (styrenesulfonate) (PEDOT:PSS) for conductive sensors has a limited conductivity due to its high sheet resistance. A physical treatment performed during the printing process has reduced the sheet resistance of printed PEDOT:PSS on polyethylenterephthalat (PET) substrate from 264.39 Ω/sq to 23.44 Ω/sq. The adhesion bonding force between printed PEDOT:PSS and the substrate PET is increased by using chemical treatment and tested using a newly designed adhesive peeling force test. Using the economical conductive ink PEDOT:PSS with this new physical treatment, our capacitive sensors are cost-efficient and have a sensitivity of up to 1.25 pF/mm.


2019 ◽  
Author(s):  
Jeba Anandh S ◽  
Anandharaj M ◽  
Aswinrajan J ◽  
Karankumar G ◽  
Karthik P

2011 ◽  
Vol 1 (1) ◽  
pp. 68-85 ◽  
Author(s):  
Patty Chuang ◽  
Stephanie Trottier ◽  
Susan Murcott

The UN defines water supplies as ‘improved’ or ‘unimproved.’ These indicators are easy to measure, but do not reflect water quality, which requires laboratory or field tests. Laboratory and test availability, expense and technical capacity are obstacles for developing countries. This research compares and verifies four low-cost, field-based microbiological tests: the EC-Kit (Colilert® and Petrifilm™ tests), the H2S bacteria test, and Easygel®, against a standard method (Quanti-Tray®). The objectives are to: (1) verify the accuracy of the four field-based tests, (2) study the accuracy of these tests as a function of improved and unimproved sources; (3) recommend a single microbiological test, if appropriate, based on accuracy and cost, and/or (4) recommend a testing combination, if appropriate, based on accuracy and cost. The tests of 500+ total water samples from Capiz Province, Philippines and Cambridge, MA indicate that two-tests systems gave better results than a single test. Both the 100-mL H2S test + Petrifilm™ and the 20-mL H2S test + Easygel® combinations yield promising results, in addition to being inexpensive. None of the field-based tests should be used on their own. We recommend further verification of a larger sample size and scale be undertaken before these testing combinations are recommended for wider use.


Author(s):  
JOSEINA MOUTINHO TAVARES ◽  
Anderson Silva de Oliveira ◽  
Paulo Moutinho Andrade de Souza ◽  
Walter da Silva Junior

This work aims to evaluate the quality of drinking water in the communities of Baiacu, Sao Francisco do Conde, Santo Amaro and Cachoeira. It was verified that in some places of Santo Amaro and Sao Francisco do Conde, from the microbiological point of view, it is not appropriate for consumption, because it was found that the presence of total coliforms in 50% of the samples and that the chlorine content is below the values indicated by the standards in 75% of the analyzed samples. Thus, the consumption of contaminated water can cause diseases, so it is recommended cleaning of residential reservoirs, maintenance in pipes periodically, as well as the need for continuous monitoring of water quality and the intense participation of public agencies in these actions. Through these actions and the active participation of the population, one can preserve the environment and the lives of all those who transit in the communities of the Bay of All Saints


2018 ◽  
Vol 7 (2.8) ◽  
pp. 419
Author(s):  
K Geetha ◽  
P Prabha ◽  
C Preetha Devi ◽  
S Priyadharshini ◽  
S Tamilselvan

Now a days, Industries are more equipped with automatic system. Fire monitoring is one of the applications where continuous monitoring of temperature and humidity is essential to detect the fire in the industry. Fire detection is very much necessary to protect both the industry and to conserve environment and livelihood of human. This paper presents an algorithm to detect the fire in the industry based on ZigBee and GPRS wireless sensor network which provides low cost, low maintenance and good quality service when compared with the traditional method. The hardware circuitry of proposed solution is based on microcontroller, temperature sensor along with ZigBee and GPRS modules.


Sign in / Sign up

Export Citation Format

Share Document