scholarly journals Evaluation of Potential Geographic Distribution for Large-Scale Photovoltaic System in Suburbs of China

2013 ◽  
Vol 2013 ◽  
pp. 1-8 ◽  
Author(s):  
Masashi Kawase ◽  
Keiichi Okajima ◽  
Yohji Uchiyama

Since China is the largest CO2emitting country in the world, photovoltaic (PV) systems are expected to be widely installed to reduce CO2emission. In general, available area for PV installation depends on urban area due to differences in land use and slope. Amount of electricity generated by a PV system also depends on urban area because of differences in solar irradiation and ambient temperature. The aim of this study is to evaluate the installation of large-scale PV systems in suburbs of China, taking these differences into consideration. We have used a geographic information system (GIS) to evaluate amounts of installation capacity of large-scale PV systems, electricity generated, and CO2emission reduction by the installation capacity of large-scale PV systems in suburbs of Liaoning, Shanghai, Anhui, and Guangdong. In Liaoning, the amount of CO2emission reduction by the installation capacity of large-scale PV systems was estimated to be the largest, 3,058 kt-CO2/yr, due to its larger amount of the installation capacity, 2439.4 MW, than the amount of the installation capacity in other regions.

Author(s):  
L. Bouhaki ◽  
R. Saadani ◽  
R. Agounoun ◽  
K. Sbai ◽  
M. Rahmoune

Photovoltaic (PV) systems are the most promising renewable energy source in Morocco due to its abundant solar irradiation. The Moroccan government has launched various renewable energy programs to encourage the use of PV systems. In this work we present a comparative study in terms of energy produced and the efficiency of a grid connected photovoltaic (PV) system installed on the roof of the building occupied by the “Ecole Supérieure de Technologie de Meknes” (ESTM). The on-grid connected photovoltaic system has a total power of 5860 Watts (Wp). This system provides an average daily reduction of 30 kWh in the consumption of electrical energy at ESTM facilities; this will allow us to save fossil fuels and reduce emissions of greenhouse gas. The average annual production of electric power is estimated at 10.5 MWh, equivalent to burning 0.9 tons of oil, which will prevent the emission of about 2 tons / year of CO2 in the atmosphere. Three different commercial solar modules, manufactured with different materials and technologies in monocrystalline silicon, polycrystalline silicon and amorphous silicon were tested.


2014 ◽  
Vol 60 (4) ◽  
pp. 315-320 ◽  
Author(s):  
Gustaw Mazurek

Abstract Estimation of Global Tilted Irradiation (GTI) is a key to performance assessment of typical solar systems since they usually employ tilted photovoltaic (PV) modules or collectors. Numerous solar radiation databases can deliver irradiation values both on horizontal and tilted plane, however they are validated mostly with horizontal-plane ground measurements. In this paper we have compared GTI estimates retrieved from five Internet databases with results of measurements at two PV systems located in Poland. Our work shows that in spite of good agreement in annual scale, there is a tendency to underestimate GTI in summer and overestimate in winter, when PV modules can receive less than a half of expected irradiation. The latter issue affects sizing of PV system components and implies a correction needed to achieve all-year long operation.


Energies ◽  
2019 ◽  
Vol 12 (19) ◽  
pp. 3743
Author(s):  
Rui Li ◽  
Fangyuan Shi ◽  
Xu Cai ◽  
Haibo Xu

Photovoltaic (PV) power generation has shown a trend towards large-scale medium- or high-voltage integration in recent years. The development of high-frequency link PV systems is necessary for the further improvement of system efficiency and the reduction of system cost. In the system, high-frequency high-step-up ratio LLC converters are one of the most important parts. However, the parasitic parameters of devices lead to a loss of zero-voltage switching (ZVS) in the LLC converter, greatly reducing the efficiency of the system, especially in such a high-frequency application. In this paper, a high-frequency link 35 kV PV system is presented. To suppress the influences of parasitic parameters in the LLC converter in the 35 kV PV system, the influence of parasitic parameters on ZVS is analyzed and expounded. Then, a suppression method is proposed to promote the realization of ZVS. This method adds a saturable inductor on the secondary side to achieve ZVS. The saturable inductor can effectively prevent the parasitic elements of the secondary side from participating in the resonance of the primary side. The experimental results show that this method achieves a higher efficiency than the traditional method by reducing the magnetic inductance.


Energies ◽  
2018 ◽  
Vol 11 (11) ◽  
pp. 3152 ◽  
Author(s):  
Huadian Xu ◽  
Jianhui Su ◽  
Ning Liu ◽  
Yong Shi

Conventional photovoltaic (PV) systems interfaced by grid-connected inverters fail to support the grid and participate in frequency regulation. Furthermore, reduced system inertia as a result of the integration of conventional PV systems may lead to an increased frequency deviation of the grid for contingencies. In this paper, a grid-supporting PV system, which can provide inertia and participate in frequency regulation through virtual synchronous generator (VSG) technology and an energy storage unit, is proposed. The function of supporting the grid is implemented in a practical PV system through using the presented control scheme and topology. Compared with the conventional PV system, the grid-supporting PV system, behaving as an inertial voltage source like synchronous generators, has the capability of participating in frequency regulation and providing inertia. Moreover, the proposed PV system can mitigate autonomously the power imbalance between generation and consumption, filter the PV power, and operate without the phase-locked loop after initial synchronization. Performance analysis is conducted and the stability constraint is theoretically formulated. The novel PV system is validated on a modified CIGRE benchmark under different cases, being compared with the conventional PV system. The verifications demonstrate the grid support functions of the proposed PV system.


Author(s):  
Mohammed Bouzidi ◽  
Abdelkader Harrouz ◽  
Tadj Mohammed ◽  
Smail Mansouri

<p>The inverter is the principal part of the photovoltaic (PV) systems that assures the direct current/alternating current (DC/AC) conversion (PV array is connected directly to an inverter that converts the DC energy produced by the PV array into AC energy that is directly connected to the electric utility). In this paper, we present a simple method for detecting faults that occurred during the operation of the inverter. These types of faults or faults affect the efficiency and cost-effectiveness of the photovoltaic system, especially the inverter, which is the main component responsible for the conversion. Hence, we have shown first the faults obtained in the case of the short circuit. Second, the open circuit failure is studied. The results demonstrate the efficacy of the proposed method. Good monitoring and detection of faults in the inverter can increase the system's reliability and decrease the undesirable faults that appeared in the PV system. The system behavior is tested under variable parameters and conditions using MATLAB/Simulink.</p>


2013 ◽  
Vol 479-480 ◽  
pp. 590-594
Author(s):  
Wei Lin Hsieh ◽  
Chia Hung Lin ◽  
Chao Shun Chen ◽  
Cheng Ting Hsu ◽  
Chin Ying Ho ◽  
...  

The penetration level of a PV system is often limited due to the violation of voltage variation introduced by the large intermittent power generation. This paper discusses the use of an active power curtailment strategy to reduce PV power injection during peak solar irradiation to prevent voltage violation so that the PV penetration level of a distribution feeder can be increased to fully utilize solar energy. When using the proposed voltage control scheme for limiting PV power injection into the study distribution feeder during high solar irradiation periods, the total power generation and total energy delivered by the PV system over a 1-year period are determined according to the annual duration of solar irradiation. With the proposed voltage control to perform the partial generation rejection of PV systems, the optimal installation capacity of PV systems can be determined by maximizing the net present value of the system so that better cost effectiveness of the PV project and better utilization of solar energy can be obtained.


2019 ◽  
Vol 9 (3) ◽  
pp. 395 ◽  
Author(s):  
Sung-Min Kim ◽  
Myeongchan Oh ◽  
Hyeong-Dong Park

Photovoltaic (PV) energy is one of the most promising renewable energies in the world due to its ubiquity and sustainability. However, installation of solar panels on the ground can cause some problems, especially in countries where there is not enough space for installation. As an alternative, floating PV, with advantages in terms of efficiency and environment, has attracted attention, particularly with regard to installing large-scale floating PV for dam lakes and reservoirs in Korea. In this study, the potentiality of floating PV is evaluated, and the power production is estimated for 3401 reservoirs. To select a suitable reservoir for floating PV installation, we constructed and analyzed the water depth database using OpenAPI. We also used the typical meteorological year (TMY) data and topographical information to predict the irradiance distribution. As a result, the annual power production by all possible reservoirs was estimated to be 2932 GWh, and the annual GHG reduction amount was approximately 1,294,450 tons. In particular, Jeollanam-do has many reservoirs and was evaluated as suitable for floating PV installation because of its high solar irradiance. The results can be used to estimate priorities and potentiality as a preliminary analysis for floating PV installation.


Energies ◽  
2019 ◽  
Vol 12 (19) ◽  
pp. 3798 ◽  
Author(s):  
Mansouri ◽  
Lashab ◽  
Sera ◽  
Guerrero ◽  
Cherif

Renewable energy systems (RESs), such as photovoltaic (PV) systems, are providing increasingly larger shares of power generation. PV systems are the fastest growing generation technology today with almost ~30% increase since 2015 reaching 509.3 GWp worldwide capacity by the end of 2018 and predicted to reach 1000 GWp by 2022. Due to the fluctuating and intermittent nature of PV systems, their large-scale integration into the grid poses momentous challenges. This paper provides a review of the technical challenges, such as frequency disturbances and voltage limit violation, related to the stability issues due to the large-scale and intensive PV system penetration into the power network. Possible solutions that mitigate the effect of large-scale PV system integration on the grid are also reviewed. Finally, power system stability when faults occur are outlined as well as their respective achievable solutions.


2018 ◽  
Vol 225 ◽  
pp. 04004
Author(s):  
Tan Dei Han ◽  
Mohamad Rosman M. Razif ◽  
Shaharin A. Sulaiman

Solar photovoltaic (PV) systems has the potential of supplying infinite electricity from renewable energy to rural areas around Malaysia. Various preterm failures happening frequently on the system lead to its drop in efficiency and breakdown. Lack of studies on the system in Malaysia hinders the development in terms of operation and maintenance. There is no proper documentation relevant to the premature failure of the system in Malaysia. The main objective of this project is to study the nature of premature failure of stand-alone solar photovoltaic system in Malaysia in order to improve the operation and maintenance of the system. The present study would provide reference for proper planning on operation and maintenance of the PV system. The study was conducted base on expert’s input and extensive literature survey. FMEA method and ISM approach are applied to analyze the data collected. Poor cooling system have the highest risk priority number. Poor workmanship is the least depending factor for premature failure to happen thus requires most attention. Highest driving force of premature failure is poor monitoring and maintenance. More focus should be given to these premature failure during the planning for operation and maintenance due to its severity and impact.


Author(s):  
K. Agyenim-Boateng ◽  
R. F. Boehm

The promise of large-scale use of renewables such as wind and solar for supplying electrical power is tempered by the sources’ transient behavior and the impact this would have on the operation of the grid. One way of addressing this is through the use of supplemental energy storage. While the technology for the latter has not been proven on a large scale or to be economical at the present time, some assessments of what magnitude is required can be made. In performing this work we have used NREL’s Solar Advisor Model (SAM 2010) with TMY3 solar data to estimate the photovoltaic system power generation. Climatic conditions close to load centers were chosen for the simulations. Then the PV output for varying sizes of arrays were examined and the impact of varying amounts of storage investigated. The storage was characterized by maximum limiting energy and power capacities based on annual hourly peak load, as well as its charging and discharging efficiencies. The simulations were performed using hourly time steps with energy withdrawn from, or input to, storage only after considering base generation and the PV system output in serving the grid load. In this work, we examined the load matching capability of solar PV generation (orientated for maximum summer output) for a sample Southwestern US utility grid load of 2008. Specifically we evaluated the daily and seasonal peak load shifting with employing varying storage capacities. The annual average energy penetration based on the usable solar PV output is also examined under these conditions and at different levels of system flexibility.


Sign in / Sign up

Export Citation Format

Share Document