scholarly journals Evaluation of the Effect of Water on Three Different Light Cured Composite Restorative Materials Stored in Water: An In Vitro Study

2012 ◽  
Vol 2012 ◽  
pp. 1-5 ◽  
Author(s):  
Basawaraj Biradar ◽  
Sudharani Biradar ◽  
Arvind MS

Objectives. The objective of this in vitro study was to investigate whether weight gain or loss in the three different composites occurs due to water absorption when they are stored in water.Methods. The composite restorative materials selected for this study included a microfine hybrid (Synergy) and two nanofilled composite restorative materials (Ceram X and Filtek Supreme Ultra). Twenty specimens of each material were fabricated of each composite material. Group A: Filtek Supreme Ultra, Group B: Synergy, Group C: Ceram X. Then all the specimens were stored in 10 ml Distilled water containing test tubes and placed in incubator at 37°C for six weeks. The weight changes of these specimens were measured daily for the first week and later once a week for next five weeks by using an electrical analytical balance.Results.The data was analyzed by one-way analysis of variance and Student'sttest. All groups showed maximum amount of water absorption in the first week than gradual decrease in the water absorption from the second to the sixth week, as compared to the first week and there is no statistically significant difference between the groups tested.Conclusion. All the composite restorative material absorbs some amount of water. The water absorption of the composite may decrease the physical and mechanical properties of the composites; hence it is necessary to consider the type of the material before starting the treatment.

2017 ◽  
Vol 05 (01) ◽  
pp. 039-046 ◽  
Author(s):  
Monica Sharma ◽  
Ajay Bansal ◽  
Sunny Panthi ◽  
Shefali Malik ◽  
Atulya Sharma

Abstract Purpose: The purpose of this in vitro study was to evaluate marginal fit of cobalt- chromium (Co-Cr) copings fabricated by direct metal laser sintering system (DMLS) and conventional lost-wax technique (LW). Materials and method: Forty tooth preparations were carried out over extracted mandibular molars. They were divided into two groups A and B of 20 each. For group A Co-Cr copings were fabricated by direct metal laser sintering (DMLS) and for group B by lost wax technique (LW). Glass –ionomer cement (GIC) was used to tack the copings over their preparations. Marginal fit was then evaluated directly under the stereomicroscope. Results: The mean marginal gap of group A was 27.9 ± 2.4 μm and group B was 40.4 ±6 μm. Statistical analysis using t - test showed highly significant difference (P>.05) between the marginal mean of the DMLS (group A) compared to LW (group B). Conclusion: The DMLS copings demonstrated superior marginal fit compared to that of conventional Co-Cr casted copings.


2002 ◽  
Vol 26 (4) ◽  
pp. 371-375 ◽  
Author(s):  
Ana Beatriz Alonso Chevitarese ◽  
Orlando Chevitarese ◽  
Ivete Pomarico Ribeiro de Souza ◽  
Roberto Braga de Carvalho Vianna

The aim of this study was to evaluate the influence of prophylaxis on the sealants microleakage in 30 premolars divided into: Group A, Group B and Group C. The teeth were analyzed using the optical microscope (OM) and at scanning electron microscope (SEM). There was a statitical significant difference among the groups regarding the presence of microleakage, but not with the presence of tags.


2018 ◽  
Vol 8 (1) ◽  
pp. 33-36
Author(s):  
Shaista N Ansari ◽  
Dhananjay Rathod ◽  
G P Rathod ◽  
Gazal Bisht

Objective: To assess in vitro changes in the shade of clear elastomeric modules from different manufacturers influenced by exogeneous pigmentation contained in everyday dietary substances.Materials & Method: The specimen comprised of clear elastomeric modules (Group A: Libral, Group B: TP Orthodontics) which were immersed in dietary substances: ketchup, coffee, tea, pepsi & methylene blue. Their hue, saturation and intensity were figured after 72 hours by methods of Adobe photoshop CS3 to mirror the module recoloring seriousness.Result: Significant difference was found between two types of modules analyzed in this study. Ketchup and methylene blue demonstrated higher staining potential compared to other staining media. Besides, there was no significant difference in staining contrast between tea and Pepsi.Conclusion: Ketchup and methylene blue are strong staining media, ought to be avoided by the patients opting for aesthetic orthodontic appliances. Elastomeric modules manufactured by different companies have differing staining potential. 


2021 ◽  
Vol 2021 ◽  
pp. 1-10
Author(s):  
Zahraa Abdulaali Al-Ibraheemi ◽  
Huda Abbas Abdullah ◽  
Nada Abdlameer Jawad ◽  
Julfikar Haider

During restorative treatment, premolars restored with resin filling materials using the conventional incremental-fill technique take longer restoration time and undermine the integrity of the tooth. The aim of this study was to assess fracture resistance of premolars restored by various types of novel bulk-fill composite resin materials. Forty-eight (n = 48) freshly extracted sound maxillary first premolars were used in this in vitro study. The teeth were divided into six groups, each having 8 specimens. Group A (positive control) was allocated for the intact teeth. For specimens in Groups B to F, a large cavity (Class-II MOD) was prepared with a standardized dimension of cavity (3 mm depth on the pulpal floor, 4 mm at the gingival seat, and 3 mm cavity width). Group B represented prepared teeth without any restoration. Group C, Group D, Group E, and Group F were restored with Tetric EvoCeram® incremental-fill (conventional), Beautifil bulk-fill, Filtek posterior bulk-fill, and SonicFill 2 bulk-fill restorative materials, respectively. All samples were finished and polished with an enhanced finishing kit and stored in distilled water for a month before the fracture resistance testing. All the samples were exposed to the axial loading (the speed of crosshead was 1 mm/min) in a computer-controlled universal testing machine (LARYEE, China) via a steel bar (6 mm in diameter) and the maximum applied force in Newton was recorded as the fracture resistance. One-way analysis of variance (SPSS 21) was used to compare the fracture resistance within the groups, and Tukey’s post hoc test was used to determine the difference between the groups. The lowest value of fracture resistance was recorded for Group B, and the highest value was recorded for Group A followed by the values of Group D, Group C, Group F, and Group E. One-way ANOVA revealed a statistically significant difference between the groups ( P < 0.05 ). Nonsignificant difference was found between the premolars restored by bulk-fill and conventional composites. Among the bulk-fill restored specimens, Beautifil restorative demonstrated significantly higher fracture resistance in comparison with the other two bulk-fill restored specimen groups (SonicFill 2 and Filtek). Bulk-fill composite such as Beautifil could be an alternative option to conventional incremental-fill composite for premolar restoration.


2011 ◽  
Vol 35 (3) ◽  
pp. 277-282 ◽  
Author(s):  
TR Chaitra ◽  
VV Subba Reddy ◽  
GM Devarasa ◽  
TL Ravishankar

Objective: Preventive procedures using pit and fissure sealants are one of the important aspects of pediatric dental practice. The objectives of this in vitro study were to comparatively evaluate microleakage and resin tag penetration of a flowable resin used as a sealant on molars after preparation with Conventional, Enameloplasty and Fissurotomy techniques. Method: A total of 48 teeth were divided into 3 groups (n-16). Group A(CST),Group B (EST),and Group C (FT). Following the fissure preparation sealant was applied as per manufacturer's instructions. 8 samples in each group were used for Microleakage and Resin tag analysis. Microleakage analysis was done under Stereomicroscope after Methylene blue dye immersion by using scoring system. The resin tag analysis was done by measuring the length of resin tags on scanning electron microscope (SEM) images consisting of 10μm scale taken under optical zoom of 2000 X. Results: Significantly lesser microleakage score (P&lt;0.01) and longer resin tag penetration (P&lt;0.001) observed in EST(mean score 0.5±0.53) & (12.19±1.93μm) when compared to CST(mean score 1.75±0.89) & (5.96±1.84μm)and FT (mean score 1.5±0.53) & (6.76±1.82μm) which showed more microleakage and short resin tags. No statistical significance between CST and FT was found. Conclusion: EST has proven to be an excellent method for preparation of pits and fissures when Flowable composite is used as a sealant because of its lesser microleakage and longer resin tag penetration.


Author(s):  
Elisa Morales-Quiroga ◽  
Alan Martínez-Zumarán ◽  
Juan Francisco Hernández-Sierra ◽  
Amaury Pozos-Guillén

<p><span>The objective of this study was to evaluate the marginal seal effectiveness and microleakage of a pit and fissure sealant containing silver nanoparticles (AgNPs). An experimental in vitro study was carried out using 40 extracted temporary molars without caries or incipient caries. These molars were divided into two groups: Group A (20 molars), to which a silver nanoparticle-containing sealant was applied, and Group B (20 molars), to which a conventional sealant was applied. The marginal seal and microleakage were evaluated. No significant differences in the marginal seal or microleakage were noted between the silver nanoparticle-containing sealant and the conventional sealant.The addition of AgNPs does not alter the adhesion or resistance of the sealant. </span></p>


2019 ◽  
Vol 7 (23) ◽  
pp. 4120-4126
Author(s):  
Zhaleh Bamdadian ◽  
Nilgoon Pasdar ◽  
Abdolhamid Alhavaz ◽  
Shahram Ghasemi ◽  
Ali Bijani

BACKGROUND: There is some cases of perforation and undesirable properties of some primary molars stainless steel crowns. AIM: The aim of this study was to compare the physical and mechanical properties of different commercial brands of these crowns. METHODS: In an in vitro study, a total of 10 stainless steel tooth crowns of the second primary mandibular molars size 6 of 4 different commercial brands (a total of 280 crowns) were evaluated. These crowns were included KTR Pre-trimmed and Crimped Nichro Stainless Steel Primary Molar Crowns (KTR, China); 3M Stainless Steel Primary Molar Crowns (ESPE, St paul; USA); NuSmile SSC Pre-contoured (Inc, Houstone, TX; USA) and Kids crown (Shinghung, Seoul; Korea). Corrosion and galvanic corrosion, wear, microhardness, compressive strength, fatigue strength of crowns and weight percent of elements were investigated. RESULTS: The highest rate of microhardness, compressive and Fatigue strength of the crowns were made by Nu Smile > 3M > Kids Crown > KTR respectively. The highest rate of corrosion potential in corrosion and Galvanic corrosion tests was in KTR > Kids crowns > 3M > Nu smile respectively. The order of crown wear was KTR > Kids Crown > 3M > Nu Smile respectively. The highest amount of nickel element was found in the Nu Smile crown and the highest amount of chrome in the 3M crown with a significant difference with others (p < 0.001). The KTR and Kids crowns lacked molybdenum. CONCLUSION: The results showed that Nu Smile crown has better physical and mechanical properties than other evaluated crowns in this study.


2012 ◽  
Vol 624 ◽  
pp. 98-102
Author(s):  
Yao Kun Zhang ◽  
Long Quan Shao ◽  
Ruo Yu Liu ◽  
Lin Lin Wang ◽  
Jun Ai ◽  
...  

The aim of this invitro study was to evaluate the fracture resistance of endodontically treated canines restored with one-piece milled zirconia post and core in the varying ferrule modes. Fifty recently extracted human maxillary canines were endodontically treated and randomly divided into 5 groups of 10 specimens each. According to the defect degree of ferrule, intact ferrule was classified as group A and served as control, 2 mm ferrule height without buccal ferrule was classified as group B, 2 mm ferrule height without mesial and buccal ferrule was classified as group C, 2 mm ferrule height without mesial, buccal and lingual ferrule was classified as group D, no ferrule preparation was classified as group E. All of the teeth were restored with one-piece milled zirconia post and core, and zirconia crowns. The teeth were prepared to standardized specifications. The restored teeth were loaded to fracture at a 135° angle to their long axis, at a cross-head speed 0.5 mm/min, and the load (N) at failure was recorded. Statistical analysis was performed by SNK pairwise multiple comparisons (α=0.05). The mean fracture resistance of five groups as follows: 1019.30±139.01N for group A, 861.20±105.67N for group B, 833.70±100.56N for group C, 733.20±96.91N for group D, 698.00±99.90N for group E. The fracture resistance of restored teeth between group B and group C, group D and group E had no statistically significant difference(P>0.05). The fracture resistance of the rest pairwise group comparisons had statistically significant difference(P<0.05). Increasing the absence degree of ferrule, it was found that the fracture resistance decrease. The buccal and lingual ferrule were more important than mesial ferrule for enhanced fracture resistance. This in vitro study supports evidence that reserving the buccal and lingual ferrule is a key point to increase the fracture resistance of canines restored with one-piece milled zirconia post and core.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Nur Ayman Abdul Hayei ◽  
Noor Azlin Yahya ◽  
Syarida Hasnur Safii ◽  
Roslan Saub ◽  
Rathna Devi Vaithilingam ◽  
...  

Abstract Background The influence of scaler tip design on root surface roughness, tooth substance loss and patients’ pain perception is investigated. Methods This article was divided into the following parts: Part 1 Surface roughness and substance loss: an in vitro study, which involves intact extracted teeth sectioned and treated using a piezoelectric ultrasonic device (PM200 EMS Piezon, Switzerland) with a conventional scaler tip (FS-407) and a Perio Slim (PS) scaler tip (Perio Slim DS-016A). All sectioned samples for tooth surface roughness (n = 20) and tooth substance loss (n = 46) analyses were measured and compared using a 3D surface texture analyser and scanning electron microscope (SEM) respectively, at baseline and following scaling. Part 2 Pain Perception: a clinical study, which was a split mouth study design including 30 participants with gingivitis and/or mild chronic periodontitis; treated with supra-gingival scaling from teeth #13 to #23. Subjects were randomised to group A or group B. Group A was treated first with PS scaler tips, whereas group B was treated first with conventional scaler tips. Pain perception was recorded using the visual analogue scale (VAS). Results In vitro study: both scaler tips caused significant reduction in root substance roughness after scaling (p < 0.05), but no significant difference between the two scaler tips (p > 0.05) was observed. The PS scaler tip caused statistically significantly less root substance loss (p < 0.05) when the initial thickness of the tooth was < 1000 µm. Clinical study: the participants reported significantly lesser pain score during scaling using the PS scaler tip (median: 3) than when using the conventional scaler tip (median: 5) (p < 0.05). Conclusions In the in vitro study, using a slim scaler tip design causes less tooth substance loss compared to a wider scaler tip design. In the clinical study, less pain was observed compared than a wide (conventional) scaler tip design.


2018 ◽  
Vol 11 (2) ◽  
pp. 751-757 ◽  
Author(s):  
Zahraa Abdulaali Jlekh ◽  
Zainab M. Abdul-Ameer

This in vitro study aimed to assess and compare premolars cuspal deflection that restored with different bulk fill resin materials types (SonicFillTM2, Beautifil Bulk Fill restorative, and FiltekTM Bulk Fill posterior restorative) to those incrementally restored group with conventional composite restorations (low shrinkage universal Tetric Evoceram). A total of 40 intact human maxillary first premolars were prepared into large MOD. Then teeth were randomly classified into four groups (n=10 for each group) according to restorative materials as following: Group A: Teeth were restored with Sonic FillTM2 composite, Group B: restored with Beautifil Bulk Fill restorative material, Group C: Teeth were restored with Filtek BulkTM Fill posterior restorative, and Group D: Teeth were restored with Universal Tetric Evo Ceram®. Digital microscope was used to measure intercuspal distance between two index reference points on the tips of the cusps before preparation, after preparation, and 15minutes after completion of restorations. The differences registered as cuspal deflection. All teeth were exposed to inward cuspal deflection after restoration and all groups that restored with bulk fill restoration reported lower cuspal deflection in compared to group D that restored with conventional composite in layering technique. Beautifil Bulk Fill restorative produced significantly greater cuspal deflection than other bulk fill groups. The study concluded that the use of new bulk fill restorative materials might reduce amount of cuspal deflection significantly. However, type of bulk fill restorative materials also influenced on amount of cuspal deflection so restoration with Sonic Fill™2 composite and Filtek Bulk™ Fill posterior reported lower cuspal deflection than Beautifil Bulk Fill restorative material.


Sign in / Sign up

Export Citation Format

Share Document