scholarly journals Sensitive Determination of Terazosin in Pharmaceutical Formulations and Biological Samples by Ionic-Liquid Microextraction Prior to Spectrofluorimetry

2012 ◽  
Vol 2012 ◽  
pp. 1-7 ◽  
Author(s):  
Mohsen Zeeb ◽  
Mahdi Sadeghi

An efficient and environmentally friendly sample preparation method based on the application of hydrophobic 1-Hexylpyridinium hexafluorophosphate [Hpy][PF6] ionic liquid (IL) as a microextraction solvent was proposed to preconcentrate terazosin. The performance of the microextraction method was improved by introducing a common ion of pyridinium IL into the sample solution. Due to the presence of the common ion, the solubility of IL significantly decreased. As a result, the phase separation successfully occurred even at high ionic strength, and the volume of the settled IL-phase was not influenced by variations in the ionic strength (up to 30% w/v). After preconcentration step, the enriched phase was introduced to the spectrofluorimeter for the determination of terazosin. The obtained results revealed that this system did not suffer from the limitations of that in conventional ionic-liquid microextraction. Under optimum experimental conditions, the proposed method provided a limit of detection (LOD) of 0.027 μg L−1and a relative standard deviation (R.S.D.) of 2.4%. The present method was successfully applied to terazosin determination in actual pharmaceutical formulations and biological samples. Considering the large variety of ionic liquids, the proposed microextraction method earns many merits, and will present a wide application in the future.

2010 ◽  
Vol 8 (3) ◽  
pp. 617-625 ◽  
Author(s):  
Hossein Abdolmohammad-Zadeh ◽  
Elnaz Ebrahimzadeh

AbstractA rapid dispersive liquid-liquid micro-extraction (DLLME) methodology based on the application of 1-hexylpyridinium hexafluorophosphate [C6py][PF6] ionic liquid (IL) as an extractant solvent was applied for the pre-concentration of trace levels of cobalt prior to determination by flame atomic absorption spectrometry (FAAS). 1-Phenyl-3-methyl-4-benzoyl-5-pyrazolone (PMBP) was employed as a chelator forming a Co-PMBP complex to extract cobalt ions from aqueous solution into the fine droplets of [C6py][PF6]. Some effective factors that influence the micro-extraction efficiency include the pH, the PMBP concentration, the amount of ionic liquid, the ionic strength, the temperature and the centrifugation time which were investigated and optimized. In the optimum experimental conditions, the limit of detection (3s) and the enrichment factor were 0.70 µg L−1 and 60, respectively. The relative standard deviation (RSD) for six replicate determinations of 50 µg L−1 Co was 2.36%. The calibration graph using the pre-concentration system was linear at levels 2–166 µg L−1 with a correlation coefficient of 0.9982. The applicability of the proposed method was evaluated by the determination of trace amounts of cobalt in several water samples.


2014 ◽  
Vol 2014 ◽  
pp. 1-4 ◽  
Author(s):  
J. Pérez-Outeiral ◽  
E. Millán ◽  
R. Garcia-Arrona

A simple and inexpensive method for cadmium determination in water using dispersive liquid-liquid microextraction and ultraviolet-visible spectrophotometry was developed. In order to obtain the best experimental conditions, experimental design was applied. Calibration was made in the range of 10–100 μg/L, obtaining good linearity (R2 = 0.9947). The obtained limit of detection based on calibration curve was 8.5 μg/L. Intra- and interday repeatability were checked at two levels, obtaining relative standard deviation values from 9.0 to 13.3%. The enrichment factor had a value of 73. Metal interferences were also checked and tolerable limits were evaluated. Finally, the method was applied to cadmium determination in real spiked water samples. Therefore, the method showed potential applicability for cadmium determination in highly contaminated liquid samples.


2020 ◽  
Vol 16 (5) ◽  
pp. 652-659
Author(s):  
Asiye A. Avan ◽  
Hayati Filik

Background: An Ionic Liquid-based based Dispersive Liquid-Liquid Microextraction (IL-DLLME) method was not applied to preconcentration and determination of bilirubin. Ionic Liquids (ILs) are new chemical compounds. In recent years, Ionic Liquids (ILs) have been employed as alternative solvents to toxic organic solvents. Due to these perfect properties, ILs have already been applied in many analytical extraction processes, presenting high extraction yield and selectivity for analytes. Methods: In this study, IL-DLLME was applied to biological samples (urine and serum) for the spectrophotometric detection of bilirubin. For bilirubin analysis, the full-color development was based on the reaction with periodate in the presence of hydrochloric acid. The high affinity of bilirubin for the ionic liquid phase gave extraction percentages above 98% in 0.3 M HCl solution. Results: Several IL-extraction parameters were optimized and room temperature ionic liquid 1-butyl- 1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide and ethanol were used as extraction and disperser solution. The linear range was found in the range of 0.5-6.0 μM (0.3-3.5 μg mL-1) and the limits of detection of the proposed method was 0.5 μM (0.3 μg mL-1). The proposed method was applied for the preconcentration and separation of trace bilirubin in real urine samples. Also, the recoveries for bilirubin in spiked biological samples (urine and serum) were found to be acceptable, between 95-102%. Conclusion: The proposed IL-DLLMEapproach was employed for the enrichment and determination of trace levels of bilirubin in urine samples using NaIO4 as an oxidizing agent and Uv-vis spectrophotometric detection. The periodate oxidation of bilirubin is rapid, effective, selective, and simple to perform. The method contains only HCl, NaOI4, and an anionic surfactant. The method may be useful for economizing in the consumption of reagents in bilirubin determining. The IL-DLLMEmethod ensures a high yield and has a low toxicity no skin sensitization, no mutagenicity and no ecotoxicity in an aquatic environment since only very low quantities of an IL is required. For full-color formation, no any extra auxiliary reagents are required. Besides, the IL-DLLME technique uses a low-cost instrument such as Uv-vis which is present in most of the medical laboratories.


2013 ◽  
Vol 2013 ◽  
pp. 1-5
Author(s):  
Mohsen Keyvanfard ◽  
Khadijeh Alizad ◽  
Razieh Shakeri

A new kinetic spectrophotometric method is described for the determination of ultratrace amounts of sodium cromoglycate (SCG). The method based on catalytic action of SCG on the oxidation of amaranth with periodate in acidic and micellar medium. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of the amaranth at 518 nm, for the first 4 min from initiation of the reaction. Calibration curve was linear in the range of 4.0−36.0 ng mL−1SCG. The limit of detection is 2.7 ng mL−1SCG. The relative standard deviation (RSD) for ten replicate analyses of 12, 20, and 28 ng mL−1SCG was 0.40%, 0.32%, and 0.53%, respectively. The proposed method was used for the determination of SCG in biological samples.


Author(s):  
Jaspreet Kaur ◽  
Daljit Kaur ◽  
Sukhmeet Singh

Objective: A simple, accurate, and selective ultraviolet-spectrophotometric method has been developed for the estimation of febuxostat in the bulk and pharmaceutical dosage forms.Method: The method was developed and validated according to International Conference on Harmonization (ICH Q2 R1) guidelines. The developed method was validated statistically with respect to linearity, range, precision, accuracy, ruggedness, limit of detection (LOD), limit of quantitation (LOQ), and recovery. Specificity of the method was demonstrated by applying different stressed conditions to drug samples such as acid hydrolysis, alkaline hydrolysis, oxidative, photolytic, and thermal degradation.Results: The study was conducted using phosphate buffer pH 6.8 and λmax was found to be 312 nm. Standard plot having a concentration range of 1–10 μg/ml showed a good linear relationship with R2=0.999. The LOD and LOQ were found to be 0.118 μg/ml and 0.595 μg/ml, respectively. Recovery and percentage relative standard deviations were found to be 100.157±0.332% and <2%, respectively.Conclusion: Proposed method was successfully applicable to the pharmaceutical formulations containing febuxostat. Thus, the developed method is found to be simple, sensitive, accurate, precise, reproducible, and economical for the determination of febuxostat in pharmaceutical dosage forms.


2014 ◽  
Vol 675-677 ◽  
pp. 181-184 ◽  
Author(s):  
Gui Qi Huang ◽  
She Ying Dong ◽  
Zhen Yang ◽  
Ting Lin Huang

An ultrasound-assisted ionic liquid based dispersive liquid-liquid microextraction (UA-IL-DLLME) was developed for the determination of four plant hormones (6-benzyladenine (6-BA), kinetin (6-KT), 2, 4-dichlorophenoxy acetic acid (2, 4-D) and uniconazole (UN)) in soil, using high performance liquid chromatography (HPLC)-diode array detection (DAD). Several important parameters including the type and volume of extraction solvent, the volume of disperser solvent, ultrasound time, pH of the solution and salt effect were studied and optimized. Under optimum conditions, the limits of detections (LODs) for the target analytes were in the range of 0.002-0.01 μg g-1. And satisfactory recoveries of the target analytes in the soil samples were 79.3-96.7 %, with relative standard deviations (RSD, n=5) that ranged from 4.3 to 6.7%.


Author(s):  
Salma M.Z. Al-Kindy ◽  
Arwa Al-Ghazali ◽  
Fakhr Eldin O. Suliman ◽  
Haidar A.J. Al-Lawati

A sensitive time-resolved luminescence method for the determination of flubiprofen (FLP) in methanol and in aqueous solution is described. The method is based on the luminescence sensitization of terbium (Tb3+ ) by the formation of a ternary complex with FLP in the presence of 4,7 diphenyl 1,10 phenanthroline (DPP) as co-ligand, and Tween-20 as surfactant. The signal for Tb-FLP-DPP was monitored at λex  = 285 nm and λem  = 552 nm. Optimum conditions for the formation of the complex in an aqueous system were TRIS buffer, pH 8.0, DPP (2.5Å~10−7  M), Tween-20 (0.30%) and 4Å~10-5  mol L-1  of Tb3+  which allowed the determination of 20–1000 ng mL-1  of FLP with a limit of detection (LOD) of 10 ng mL-1 . The relative standard deviations of the method ranged between 0.6 and 1.4% indicating excellent reproducibility of the method. The proposed method was successfully applied for the assays of FLP in pharmaceutical formulations and spiked tap water samples with average recoveries of 87% – 95%. 


Author(s):  
Mohamed A Hammad ◽  
Amira H Kamal ◽  
Reham E Kannouma ◽  
Fotouh R Mansour

Abstract A validated method for preconcentration and determination of nateglinide in plasma was developed using vortex-assisted dispersive liquid–liquid microextraction. Different variables that affect extraction efficiency were studied and optimized, including type and volume of extractant, type and volume of disperser, pH of diluent, salt addition effect, centrifugation and vortex time. Nateglinide was extracted using 30 μL of 1-octanol as an extractant and 200 μL of methanol as a disperser. The enrichment factor reached 330 under the optimum conditions. High-performance liquid chromatography/ultraviolet was used for detection using phosphate buffer (pH 2.5, 10 mM): acetonitrile (45:55, v/v) as a mobile phase at a flow rate of 1 mL/min. The method was linear over the range of 50–20,000 ng/mL with a limit of detection of 15 ng/mL (signal-to-noise ratio = 3). Intra- and inter-day precision had %relative standard deviation &lt;6% (n = 3) and the %recoveries were found to be between 102.5 and 105.9%. The proposed method is simple, sensitive, eco-friendly, cost-effective and powerful for microextraction of nateglinide from human plasma samples.


Sign in / Sign up

Export Citation Format

Share Document