scholarly journals Three-Dimensional Acoustic Source Mapping with Different Beamforming Steering Vector Formulations

2012 ◽  
Vol 2012 ◽  
pp. 1-12 ◽  
Author(s):  
Ennes Sarradj

Acoustic source mapping techniques using acoustic sensor arrays and delay-and-sum beamforming techniques suffer from bad spatial resolution at low-aperture-based Helmholtz numbers. This is especially a problem for three-dimensional map grids, when the sensor array is not arranged around the region spanned by the grid but on only one side of it. Then, the spatial resolution of the result map in the direction pointing away from the array is much worse than in the other lateral directions. Consequently, deconvolution techniques need to be applied. Some of the most efficient deconvolution techniques rely on the properties of the spatial beamformer filters used. As these properties are governed by the steering vectors, four different steering vector formulations from the literature are examined, and their theoretical background is discussed. It is found that none of the formulations provide both the correct location and source strength. As a practical example the CLEAN-SC deconvolution methodology is applied to simulated data for a three-source scenario. It is shown that the different steering vector formulations are not equally well suited for three-dimensional application. The two preferred formulations enable the correct estimation of the source location at the cost of a negligible error in the estimated source strength.

Actuators ◽  
2021 ◽  
Vol 10 (4) ◽  
pp. 78
Author(s):  
Tomislav Strinić ◽  
Bianca Wex ◽  
Gerald Jungmayr ◽  
Thomas Stallinger ◽  
Jörg Frevert ◽  
...  

A sealless pump, also known as a wet rotor pump or a canned pump, requires a stationary sleeve in the air gap to protect the stator from a medium that flows around the rotor and the pump impeller. Since the sleeve is typically made from a non-magnetic electrically conductive material, the time-varying magnetic flux density in the air gap creates an eddy current loss in the sleeve. Precise assessment of this loss is crucial for the design of the pump. This paper presents a method for calculating the eddy current loss in such sleeves by using only a two-dimensional (2D) finite element method (FEM) solver. The basic idea is to use the similar structure of Ampère’s circuital law and Faraday’s law of induction to solve eddy current problems with a magnetostatic solver. The theoretical background behind the proposed method is explained and applied to the sleeve of a sealless pump. Finally, the results obtained by a 2D FEM approach are verified by three-dimensional FEM transient simulations.


Micromachines ◽  
2021 ◽  
Vol 12 (5) ◽  
pp. 569
Author(s):  
Jianzhong Chen ◽  
Ke Sun ◽  
Rong Zheng ◽  
Yi Sun ◽  
Heng Yang ◽  
...  

In this study, we developed a radial artery pulse acquisition system based on finger-worn dense pressure sensor arrays to enable three-dimensional pulse signals acquisition. The finger-worn dense pressure-sensor arrays were fabricated by packaging 18 ultra-small MEMS pressure sensors (0.4 mm × 0.4 mm × 0.2 mm each) with a pitch of 0.65 mm on flexible printed circuit boards. Pulse signals are measured and recorded simultaneously when traditional Chinese medicine practitioners wear the arrays on the fingers while palpating the radial pulse. Given that the pitches are much smaller than the diameter of the human radial artery, three-dimensional pulse envelope images can be measured with the system, as can the width and the dynamic width of the pulse signals. Furthermore, the array has an effective span of 11.6 mm—3–5 times the diameter of the radial artery—which enables easy and accurate positioning of the sensor array on the radial artery. This study also outlines proposed methods for measuring the pulse width and dynamic pulse width. The dynamic pulse widths of three volunteers were measured, and the dynamic pulse width measurements were consistent with those obtained by color Doppler ultrasound. The pulse wave velocity can also be measured with the system by measuring the pulse transit time between the pulse signals at the brachial and radial arteries using the finger-worn sensor arrays.


2011 ◽  
Vol 32 (3) ◽  
pp. 489-501 ◽  
Author(s):  
Adriana T Perles-Barbacaru ◽  
Boudewijn PJ van der Sanden ◽  
Regine Farion ◽  
Hana Lahrech

To assess angiogenesis noninvasively in a C6 rat brain tumor model, the rapid-steady-state- T1 (RSST1) magnetic resonance imaging (MRI) method was used for microvascular blood volume fraction (BVf) quantification with a novel contrast agent gadolinium per (3,6 anhydro) α-cyclodextrin (Gd-ACX). In brain tissue contralateral to the tumor, equal BVfs were obtained with Gd-ACX and the clinically approved gadoterate meglumine (Gd-DOTA). Contrary to Gd-DOTA, which leaks out of the tumor vasculature, Gd-ACX was shown to remain vascular in the tumor tissue allowing quantification of the tumor BVf. We sought to confirm the obtained tumor BVf using an independent method: instead of using a ‘standard’ two-dimensional histologic method, we study here how vascular morphometry combined with a stereological technique can be used for three-dimensional assessment of the vascular volume fraction ( VV). The VV is calculated from the vascular diameter and length density. First, the technique is evaluated on simulated data and the healthy rat brain vasculature and is then applied to the same C6 tumor vasculature previously quantified by RSST1-MRI with Gd-ACX. The mean perfused VV and the BVf obtained by MRI in tumor regions are practically equal and the technique confirms the spatial heterogeneity revealed by MRI.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Parsa Omidi ◽  
Mohamadreza Najiminaini ◽  
Mamadou Diop ◽  
Jeffrey J. L. Carson

AbstractSpatial resolution in three-dimensional fringe projection profilometry is determined in large part by the number and spacing of fringes projected onto an object. Due to the intensity-based nature of fringe projection profilometry, fringe patterns must be generated in succession, which is time-consuming. As a result, the surface features of highly dynamic objects are difficult to measure. Here, we introduce multispectral fringe projection profilometry, a novel method that utilizes multispectral illumination to project a multispectral fringe pattern onto an object combined with a multispectral camera to detect the deformation of the fringe patterns due to the object. The multispectral camera enables the detection of 8 unique monochrome fringe patterns representing 4 distinct directions in a single snapshot. Furthermore, for each direction, the camera detects two π-phase shifted fringe patterns. Each pair of fringe patterns can be differenced to generate a differential fringe pattern that corrects for illumination offsets and mitigates the effects of glare from highly reflective surfaces. The new multispectral method solves many practical problems related to conventional fringe projection profilometry and doubles the effective spatial resolution. The method is suitable for high-quality fast 3D profilometry at video frame rates.


1984 ◽  
Vol 106 (1) ◽  
pp. 72-78 ◽  
Author(s):  
D. E. Olson ◽  
K. H. Parker ◽  
B. Snyder

This report describes the theory and operation of a pulsed-probe anemometer designed to measure steady three-dimensional velocity fields typical of pulmonary tracheo-bronchial airflows. Local velocities are determined by measuring the transport time and orientation of a thermal pulse initiated at an upstream wire and sensed at a downstream wire. The transport time is a reproducible function of velocity and the probe wire spacing, as verified by a theoretical model of convective heat transfer. When calibrated the anemometer yields measurements of velocity accurate to ±5 percent and resolves flow direction to within 1 deg at airspeeds ≥10 cm/s. Spatial resolution is ±0.5 mm. Measured flow patterns typical of curved circular pipes are included as examples of its application.


2021 ◽  
Vol 5 (1) ◽  
pp. 21
Author(s):  
Edgar G. Mendez-Lopez ◽  
Jersson X. Leon-Medina ◽  
Diego A. Tibaduiza

Electronic tongue type sensor arrays are made of different materials with the property of capturing signals independently by each sensor. The signals captured when conducting electrochemical tests often have high dimensionality, which increases when performing the data unfolding process. This unfolding process consists of arranging the data coming from different experiments, sensors, and sample times, thus the obtained information is arranged in a two-dimensional matrix. In this work, a description of a tool for the analysis of electronic tongue signals is developed. This tool is developed in Matlab® App Designer, to process and classify the data from different substances analyzed by an electronic tongue type sensor array. The data processing is carried out through the execution of the following stages: (1) data unfolding, (2) normalization, (3) dimensionality reduction, (4) classification through a supervised machine learning model, and finally (5) a cross-validation procedure to calculate a set of classification performance measures. Some important characteristics of this tool are the possibility to tune the parameters of the dimensionality reduction and classifier algorithms, and also plot the two and three-dimensional scatter plot of the features after reduced the dimensionality. This to see the data separability between classes and compatibility in each class. This interface is successfully tested with two electronic tongue sensor array datasets with multi-frequency large amplitude pulse voltammetry (MLAPV) signals. The developed graphical user interface allows comparing different methods in each of the mentioned stages to find the best combination of methods and thus obtain the highest values of classification performance measures.


2015 ◽  
Vol 9 (1) ◽  
pp. 1-11
Author(s):  
Gábor Bakó ◽  
Gábor Kovács ◽  
Zsolt Molnár ◽  
Judit Kirisics ◽  
Eszter Góber ◽  
...  

The red mud disaster occurred on 4th October 2010 in Hungary has raised the necessity of rapid intervention and drew attention to the long-term monitoring of such threat. Both the condition assessment and the change monitoring indispensably required the prompt and detailed spatial survey of the impact area. It was conducted by several research groups - independently - with different recent surveying methods. The high spatial resolution multispectral aerial photogrammetry is the spatially detailed (high resolution) and accurate type of remote sensing. The hyperspectral remote sensing provides more information about material quality of pollutants, with less spatial details and lower spatial accuracy, while LIDAR ensures the three-dimensional shape and terrain models. The article focuses on the high spatial resolution, multispectral electrooptical method and the evaluation methodology of the deriving high spatial resolution ortho image map, presenting the derived environmental information database


Sign in / Sign up

Export Citation Format

Share Document