scholarly journals A Validated RP-HPLC Method for the Determination of Atazanavir in Pharmaceutical Dosage Form

2011 ◽  
Vol 8 (1) ◽  
pp. 453-456 ◽  
Author(s):  
K. Srinivasu ◽  
J. Venkateswara Rao ◽  
N. Appala Raju ◽  
K. Mukkanti

A validated RP HPLC method for the estimation of atazanavir in capsule dosage form on YMC ODS 150 × 4.6 mm, 5 μ column using mobile phase composition of ammonium dihydrogen phosphate buffer (pH 2.5) with acetonitrile (55:45 v/v). Flow rate was maintained at 1.5 mL/min with 288 nm UV detection. The retention time obtained for atazanavir was at 4.7 min. The detector response was linear in the concentration range of 30 - 600 μg/mL. This method has been validated and shown to be specific, sensitive, precise, linear, accurate, rugged, robust and fast. Hence, this method can be applied for routine quality control of atazanavir in capsule dosage forms as well as in bulk drug.

INDIAN DRUGS ◽  
2014 ◽  
Vol 51 (12) ◽  
pp. 32-36
Author(s):  
T. Vishalakhi ◽  
◽  
S. K Kumar ◽  
K Sujana ◽  
P Rani

A simple validated RP HPLC method for the estimation of rizatriptan benzoate in pharmaceutical dosage form and bulk was developed for routine analysis. This method was developed by selecting Agilent TC C18 (250 x 4.6 mm, 5 μ) column as stationary phase and acrylonibrile:water (45:55), pH adjusted to 3, as mobile phase. Flow rate of mobile phase was maintained at 4: 1 mL/min at ambient temperature throughout the experiment. Quantification was achieved with ultraviolet (DAD) detection at 220 nm. The retention time obtained for rizatriptan was 2.8 min. The detector response was linear in the concentration range of 2-25μg/mL. This method was validated and shown to be specific, sensitive, precise, linear, accurate, rugged and robust. Hence, this method can be applied for routine quality control of rizatriptan benzoate in dosage forms as well as in bulk drug.


2021 ◽  
Vol 001 (02) ◽  
Author(s):  
Shalin Parikh ◽  
Jayant Dave ◽  
Jayendrakumar Patel

A simple, precise, accurate and sensitive isocratic stability indicating RP-HPLC method has been developed and validated for determination of Ketoconazole in bulk drug and pharmaceutical dosage form. Isocratic RP-HPLC separation was achieved on Agilent C8 (150 mm ?4.6 mm, 5 µm particle size) with the mobile phase 0.3 % Triaethylamine in 20 mM potassium dihydrogen phosphate buffer pH adjusted to 4.0: Acetonitrile (68:32 % v/v) at a flow rate 1.0 ml/min. The retention time of Ketoconazole was 8.97 ± 0.50 min. The method was validated for specificity, linearity, precision, accuracy and robustness. The linear regression analysis data of calibration curve showed good linearity in concentration range 10-60 ?g/ml. The Intraday and Interday precision were 0.59-1.11 % and 0.26-1.73 % RSD respectively. The accuracy was found to be 98.11-99.26 %. The drug was subjected to the stress conditions like hydrolysis, oxidation, photolysis and dry heat. The proposed method is found to be specific with respect to degradation product formed after Acidic hydrolysis, Oxidation, Thermal and Photolytic degradation. The Ketoconazole was found to be stable under neutral hydrolytic, thermal and photolytic stress conditions. Acidic, thermal, photolytic stress conditions showed degradation. The proposed chromatographic method can be used for estimation of drug during stress testing & formal stability studies.


Author(s):  
Y. Rajesh Babu ◽  
N. Appalaraju

The aim of this paper was to develop and validate the stability indicating RP-HPLC method for the determination of Imatinib mesylate in bulk and pharmaceutical dosage forms. A simple, accurate, precise, sensitive and stability indicating RP-HPLC method has been developed for the determination of Imatinib mesylate in bulk drug and pharmaceutical dosage form, in which separations are done using develosil C18, 5μm, 150 × 4.6mm i.d. column at a flow rate of 1.0mL/min with an injection volume of 20μL. The beer’s law was obeyed over the concentration range of 5 - 35μg/mL. The correlation coefficient was found to be 0.996 and it showed good linearity, reproducibility, precision in this concentration range. The % recovery values were found to be within the limits, which showed that the method was accurate. The LOD and LOQ were calculated using statistical methods. The % RSD values were less than 2. The developed method was successfully applied for determination of Imatinib mesylate in pharmaceutical dosage form. The results obtained are in good agreement with those obtained by using the standard method.


Author(s):  
Rajesh Babu Y. ◽  
Appala Raju N.

The aim of this paper was to develop and validate the stability indicating RP-HPLC method for the determination of Pazopanib hydrochloride in bulk and pharmaceutical dosage forms. A simple, accurate, precise, sensitive and stability indicating RP-HPLC method has been developed for the determination of Pazopanib hydrochloride in bulk drug and pharmaceutical dosage form, in which separations are done using develosil C18, 5μm, 150 × 4.6mm i.d. column at a flow rate of 1.0mL/min with an injection volume of 20μL. The beer’s law was obeyed over the concentration range of 5 - 35μg/mL. The correlation coefficient was found to be 0.996 and it showed good linearity, reproducibility, precision in this concentration range. The % recovery values were found to be within the limits, which showed that the method was accurate. The LOD and LOQ were calculated using statistical methods. The % RSD values were less than 2. The developed method was successfully applied for determination of Pazopanib hydrochloride in pharmaceutical dosage form. The results obtained are in good agreement with those obtained by using the standard method.


2008 ◽  
Vol 5 (s2) ◽  
pp. 1098-1102 ◽  
Author(s):  
N. Appala Raju ◽  
J. Venkateswara Rao ◽  
K. Vanitha Prakash ◽  
K. Mukkanti ◽  
K. Srinivasu

A simple, precise, rapid and accurate reverse phase HPLC method developed for the estimation of levetiracetam in tablet dosage form. A Sun Fire C18, 250 x 4.6 mm, 5 μm partical size, with mobile phase consisting of acetonitrile and 0.03 M potassium dihydrogen phosphate (pH adjusted to 3.0 with orthophosphoric acid) in the ratio of 15:85 v/v was used. The flow rate was 1 mL /min and the effluents were monitored at 210 nm. The retention time was 5.53 min. The detector response was linear in the concentration of 20-240 μg/mL. The respective linear regression equation being Y= 22119.684 x 6829.3428. The limit of detection and limit of quantification was 0.16 and 0.5 μg/mL respectively. The percentage assay of levetiracetam was 99.87%. The method was validated by determining its accuracy, precision and system suitability. The results of the study showed that the proposed RP-HPLC method is simple, rapid, precise and accurate, which is useful for the routine determination of levetiracetam in bulk drug and in its pharmaceutical dosage form.


Author(s):  
MADHURIMA BASAK ◽  
Santhosh Reddy Gouru ◽  
Animesh Bera ◽  
Krishna veni Nagappan

Objective: The present study aims at developing an accurate precise, rapid and sensitive Reverse Phase High-Performance Liquid Chromatography (RP-HPLC) method for assessing Empagliflozin in bulk drug and in the pharmaceutical dosage form. Methods: The proposed method employs a Reverse Phase Shim Pack C18 column (250 mm × 4.6 mm id; 5 µm) using a mobile phase comprising of acetonitrile and water in the ratio of 60:40 v/v flushed at a flow rate of 1 ml/min. The eluents were monitored at 223 nm. Results: Empagliflozin was eluted at a retention time of 5.417 min and established a co-relation co-efficient (R2>0.999) over a concentration ranging from 0.0495-100µg/ml. Percentage recovery was obtained between 98-102% which indicated that the method is accurate. The Limit of Detection (LOD) and Limit of Quantitation (LOQ) were found at 0.0125µg/ml and 0.0495µg/ml, respectively. Conclusion: An RP-HPLC method which was relatively simple, accurate, rapid and precise was developed and its validation was performed for the quantitative analysis of empagliflozin in bulk and tablet dosage form (10 and 25 mg) in accordance to International Conference of Harmonization (ICH) Q2 (R1) guidelines. The proposed method may aid in routinely analyzing empagliflozin in pharmaceuticals.


Author(s):  
Sushil D. Patil ◽  
Pravin B. Shelke ◽  
Priti Aher ◽  
Maswood Ahmed Hafizur Rahman

A simple, rapid, economic, sensitive and precise HPLC method has been developed for the simultaneous determination of Sulphadoxine and Pyrimethamine in pharmaceutical dosage form by taking Tolterodine as an internal standard. The method was carried out using Phenomenex C18 (4.6ID × 250mm; 5µm) column and mobile phase comprised of methanol and Phosphate Buffer in proportion of ratio 60:40 v/v. The flow rate was 1.0mL/min and detection was carried out at 276nm. The retention time of Sulphadoxine, Pyrimethamine and Tolterodine were found to be 2.967, 4.058 and 6.908 respectively. Linearity of Sulphadoxine and Pyrimethamine in the range of 2 to 12μg/mL and 4 to 24μg/mL respectively. The % recoveries of Sulphadoxine and Pyrimethamine were found to be in between 99.93% to 99. 96 % respectively. The proposed method is suitable for the routine quality control analysis for simultaneous determination of Sulphadoxine and Pyrimethamine was in bulk and pharmaceutical dosage form.