scholarly journals RP-HPLC Determination of Atomoxetine Hydrochloride in Bulk and Pharmaceutical Formulations

2011 ◽  
Vol 8 (4) ◽  
pp. 1958-1964 ◽  
Author(s):  
H. R. Prajapati ◽  
P. N. Raveshiya ◽  
J. M. Prajapati

A reversed phase high performance liquid chromatographic (RP–HPLC) method was developed and subsequently validated for the determination of atomoxetine hydrochloride in bulk and pharmaceutical formulation. The separation was done by a PerkinElmer Brownlee analytical C8 column (260 mm x 4.6 mm, 5 µm) using methanol: 50 mM KH2PO2buffer (PH adjusted to 6.8 with 0.1 M NaOH), 80:20 v/v as an eluent. UV detection was performed at 270 nm at a flow rate 1.0 mL/min. The validation of the method was performed, and specificity, reproducibility, precision accuracy and ruggedness were confirmed. The correlation coefficient was found to be 0.997 for atomoxetine hydrochloride. The recovery was in the range of 99.94 to 100.98% and limit of quantification was found to be 5.707 µg/mL. The method is simple, rapid, selective and economical too and can be used for the routine analysis of drug in pharmaceutical formulations.

2019 ◽  
Vol 9 (01) ◽  
pp. 83-88
Author(s):  
Pinkal Patel ◽  
Nalini Patel ◽  
Kinjal Parmar

A simple, selective and rapid reversed phase High Performance Liquid Chromatographic (RP-HPLC) method has been developed and validated for the simultaneous analysis Gatifloxacin and flurbiprofen sodium in eye drops. The separation was carried out using a mobile phase consisting ACN: Buffer (pH 3.5) in the ratio of 55:45 v/v. The column used was Phenomenex luna ODS C18 (250mm X 4.6 mm i.d., 5 μm particle size) with flow rate of 1 ml / min using UV detection at 268 nm. The described method was linear over a concentration range of 2-12 μg/ml for both of Gatifloxacin and flurbiprofen sodium. The retention times of Gatifloxacin and flurbiprofen sodium were found to be 3.710 min. and 6.797 min respectively. Method was validated statistically and recovery studies were carried out. The proposed method has been applied successfully to the analysis of cited drugs either in pure form or in pharmaceutical formulations with good accuracy and precision. The method here in described can be employed for quality control and routine analysis of drugs in pharmaceutical formulations.


2008 ◽  
Vol 5 (s2) ◽  
pp. 1117-1122 ◽  
Author(s):  
B. Prasanna Kumar Reddy ◽  
Y. Ramanjaneya Reddy

A simple, selective, accurate reverse phase-high performance liquid chromatographic (RP-HPLC) method was developed and validated for the analysis of sildenafil citrate in pharmaceutical formulations. Chromatographic separation achieved isocratically on a C18column (Use Inertsil C18, 5μ , 150 mm x 4.6 mm) utilizing a mobile phase of acetonitrile/phosphate buffer (70:30, v/v, pH 7.0) at a flow rate of 0.8 mL/m with UV detection at 228 nm. The retention time was 4.087. The method is accurate (99.15-101.85%), precise (intra-day variation 0.13-1.56% and inter-day variation 0.30-1.60%) and linear within range 0.1-30 μg/mL (R2=0.999) concentration and was successfully used in monitoring left over drug. The detection limit of sildenafil citrate at a signal-to-noise ratio of 3 was 1.80 ng/mL in human plasma while quantification limit in human serum was 5.60 ng/mL. The proposed method is applicable to stability studies and routine analysis of sildenafil citrate in pharmaceutical formulations as well as in human plasma samples.


2013 ◽  
Vol 2013 ◽  
pp. 1-4 ◽  
Author(s):  
Xiaojun Shang ◽  
Suying Ma ◽  
Zheshen Li

A rapid, sensitive, and reproducible reverse phase high performance liquid chromatographic (RP-HPLC) method with UV detector for the determination of nimodipine in sustained release tablets was developed. The method involved using a SinoChoom ODS-BP C18reversed phase column (5 μm, 4.6 mm × 200 mm) and mobile phase consisting of methanol-acetonitrile-water (35 : 38 : 27, v/v). The flow rate is 1.0 mL/min, the UV detector was operated at 237 nm, and the column was maintained at 25°C. The method was validated according to official compendia guidelines. The calibration curve of nimodipine for RP-HPLC method was linear over the range of 10–100 μg/mL. The retention time was found at 7.50 min for nimodipine. The variation for interday and intraday assay was found to be less than 0.72%. The proposed RP-HPLC was proved to be suitable for the determination of nimodipine in sustained release tablets.


2010 ◽  
Vol 7 (3) ◽  
pp. 827-832 ◽  
Author(s):  
R. Kalaichelvi ◽  
B. Thangabalan ◽  
D. Srinivasa Rao

A rapid, simple and validated reversed-phase high-performance liquid chromatographic method has been developed for analysis of aripiprazole in tablet dosage form. Aripiprazole was separated on an ODS analytical column with a 40:60 (v/v) mixture of acetonitrile and triethanolamine buffer (5 mM, pH 3.5 ± 0.05 adjusted by addition of 85% phosphoric acid) as mobile phase at a flow rate of 1.5 mL min-1. The effluent was monitored by UV detection at 254 nm. Calibration plots were linear in the range of 20 to 60 µg mL-1and the LOD and LOQ were 0.411 and 1.248 µg mL-1, respectively. The high recovery and low relative standard deviation confirm the suitability of the method for routine quality control determination of aripiprazole in tablets.


INDIAN DRUGS ◽  
2013 ◽  
Vol 50 (05) ◽  
pp. 48-52
Author(s):  
A Lodhi ◽  
◽  
A Jain ◽  
B. Biswal

A validated high performance liquid chromatographic method was developed for the determination of chromium picolinate in pharmaceutical dosage forms. The analysis was performed at room temperature using a reversed-phase ODS, 5µm (250×4.6) mm column. The mobile phase consisted of acetonitrile: buffer (60:40 V/V) at a flow rate of 0.5 mL/min. The PDA-detector was set at 264 nm. The developed method showed a good linear relationship in the concentration range from 1.5 – 12.5 µg/mL with a correlation coefficient from 0.999. The limit of detection and limit of quantification were 0.0540513 and 0.1637919 µg/mL respectively.


2013 ◽  
Vol 2013 ◽  
pp. 1-4
Author(s):  
Suying Ma ◽  
Haixia Lv ◽  
Xiaojun Shang

A high performance liquid chromatographic (HPLC) method with UV detector for the determination of dyclonine hydrochloride and a gas chromatography (GC) method with flame ionization detector (FID) for the determination of camphor and menthol in lotion were developed. The developed HPLC method involved using a SinoChoom ODS-BP C18reversed-phase column (5 μm, 4.6 mm × 200 mm) and mobile phase consisting of acetonitrile : water : triethylamine in a ratio of 45 : 55 : 1.0; pH was adjusted to 3.5 with glacial acetic acid. The developed GC method for determination of camphor and menthol involved using an Agilent 19091J-413 capillary chromatographic column (30 m × 320 μm × 0.25 μm). The two methods were validated according to official compendia guidelines. The calibration of dyclonine hydrochloride for HPLC method was linear over the range of 20–200 μg/mL. The retention time was found at 6.0 min for dyclonine hydrochloride. The calibration of camphor and menthol of GC method was linear over the range of 10–2000 μg/mL. The retention time was found at 2.9 min for camphor and 3.05 min for menthol. The proposed HPLC and GC methods were proved to be suitable for the determination of dyclonine hydrochloride, camphor, and menthol in lotion.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (07) ◽  
pp. 43-49
Author(s):  
B.P. Manjula ◽  
V. G Joshi ◽  
Siddamsetty Ramachandra Setty ◽  
M Geetha ◽  

Tea tree oil, an active ingredient of skin, hair and nail care cosmeceuticals, has claims for topical antimicrobial, analgesic and anti-inflammatory activity. Its complex composition is governed by ISO 4730:2017. Terpinene-4-ol is the principal constituent of the oil (35% - 48%) followed by γ-terpinene (14% -28%), α-terpinene (6%-12%) and 1,8-cineole (≤15%). A reversed-phase, isocratic high performance liquid chromatographic method has been developed and validated for routine determination of tea tree oil based on1,8-cineole content in bulk and commercially available cosmeceuticals using C18 column, methanol-water (70:30 v/v) as mobile phase and flow rate of 1mL/min. UV detection was done at 200 nm. Linearity of the method was established for 20-100μL/mL (R2 = 0.9992) with LOD, LOQ values of 0.5594 μL/mL and 5.5941μL/mL respectively. The % RSD values for robustness and precision were <1% and recovery ranged between 99.09-102.96%. The method was successfully applied for determination of 1,8-cineole content in cosmeceuticals.


2008 ◽  
Vol 91 (4) ◽  
pp. 739-743 ◽  
Author(s):  
Andréia de Haro Moreno ◽  
Hérida Regina Nunes Salgado

Abstract A rapid, accurate, and sensitive high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of ceftazidime in pharmaceuticals. The method validation parameters yielded good results and included range, linearity, precision, accuracy, specificity, and recovery. The excipients in the commercial powder for injection did not interfere with the assay. Reversed-phase chromatography was used for the HPLC separation on a Waters C18 (WAT 054275; Milford, MA) column with methanolwater (70 + 30, v/v) as the mobile phase pumped isocratically at a flow rate of 1.0 mL/min. The effluent was monitored at 245 nm. The calibration graph for ceftazidime was linear from 50.0 to 300.0 g/mL. The values for interday and intraday precision (relative standard deviation) were &lt;1. The results obtained by the HPLC method were calculated statistically by analysis of variance. We concluded that the HPLC method is satisfactory for the determination of ceftazidime in the raw material and pharmaceuticals.


Author(s):  
Zubaidur Rahman ◽  
Vijey Aanandhi M ◽  
Sumithra M

Objective: A simple, novel, sensitive, rapid high-performance liquid chromatographic (RP-HPLC) method has been developed and validated for quantitative determination of atomoxetine HCl (ATH) in bulk and formulations.Methods: The chromatographic development was carried out on RP-HPLC. The column used as Xterra RP 18 (250 mm × 4.6 mm, 5 μ particle size), with mobile phase consisting of methanol: water 80:20 V/V. The flow rate was 1.0 mL/min and the effluents were monitored at 270 nm.Results: The retention time was found to be 5.350 min. The method was validated as per International Conference on Harmonization Guideline with respect to linearity, accuracy, precision, and robustness. The calibration curve was found to be linear over a range of 2–10 μg/mL with a regression coefficient of 0.9999. The method has proved high sensitivity and specificity.Conclusion: The results of the study showed that the proposed RP-HPLC method was simple, rapid, precise and accurate which is useful for the routine determination of ATH in bulk drug and in its pharmaceutical dosage form.


2008 ◽  
Vol 91 (5) ◽  
pp. 1070-1074 ◽  
Author(s):  
Arun M Prajapati ◽  
Satish A Patel ◽  
Natvarlal J Patel ◽  
Dipti B Patel ◽  
Sejal K Patel

Abstract This research paper describes validated reversed-phase high-performance column liquid chromatographic (RP-HPLC) and first-derivative UV spectrophotometric methods for the estimation of voriconazole (VOR) in oral suspension powder. The RP-HPLC separation was achieved on Phenomenex C18 column (250 4.6 mm id, 5 m particle size) using wateracetonitrile (40 + 60, v/v; pH adjusted to 4.5 0.02 with acetic acid) as the mobile phase at a flow rate of 1.4 mL/min and ambient temperature. Quantification was achieved with photodiode array detection at 255 nm over the concentration range of 0.11 g/mL with mean recovery of 99.49 0.83 for VOR by the RP-HPLC method. Quantification was achieved with UV detection at 266 nm over the concentration range of 820 g/mL with mean recovery of 99.74 0.664 for VOR by the first-derivative UV spectrophotometric method. These methods are simple, precise, and sensitive, and they are applicable for the determination of VOR in oral suspension powder.


Sign in / Sign up

Export Citation Format

Share Document