scholarly journals Creep Behavior of Passive Bovine Extraocular Muscle

2011 ◽  
Vol 2011 ◽  
pp. 1-6 ◽  
Author(s):  
Lawrence Yoo ◽  
Hansang Kim ◽  
Andrew Shin ◽  
Vijay Gupta ◽  
Joseph L. Demer

This paper characterized bovine extraocular muscles (EOMs) using creep, which represents long-term stretching induced by a constant force. After preliminary optimization of testing conditions, 20 fresh EOM samples were subjected to four different loading rates of 1.67, 3.33, 8.33, and 16.67%/s, after which creep was observed for 1,500 s. A published quasilinear viscoelastic (QLV) relaxation function was transformed to a creep function that was compared with data. Repeatable creep was observed for each loading rate and was similar among all six anatomical EOMs. The mean creep coefficient after 1,500 seconds for a wide range of initial loading rates was at1.37±0.03(standard deviation, SD). The creep function derived from the relaxation-based QLV model agreed with observed creep to within 2.7% following 16.67%/s ramp loading. Measured creep agrees closely with a derived QLV model of EOM relaxation, validating a previous QLV model for characterization of EOM biomechanics.

2017 ◽  
Vol 17 (7) ◽  
pp. 4493-4511 ◽  
Author(s):  
Shu-peng Ho ◽  
Liang Peng ◽  
Holger Vömel

Abstract. Radiosonde observations (RAOBs) have provided the only long-term global in situ temperature measurements in the troposphere and lower stratosphere since 1958. In this study, we use consistently reprocessed Global Positioning System (GPS) radio occultation (RO) temperature data derived from the COSMIC and Metop-A/GRAS missions from 2006 to 2014 to characterize the inter-seasonal and interannual variability of temperature biases in the upper troposphere and lower stratosphere for different radiosonde sensor types. The results show that the temperature biases for different sensor types are mainly due to (i) uncorrected solar-zenith-angle-dependent errors and (ii) change of radiation correction. The mean radiosonde–RO global daytime temperature difference in the layer from 200 to 20 hPa for Vaisala RS92 is equal to 0.20 K. The corresponding difference is equal to −0.06 K for Sippican, 0.71 K for VIZ-B2, 0.66 K for Russian AVK-MRZ, and 0.18 K for Shanghai. The global daytime trend of differences for Vaisala RS92 and RO temperature at 50 hPa is equal to 0.07 K/5 yr. Although there still exist uncertainties for Vaisala RS92 temperature measurement over different geographical locations, the global trend of temperature differences between Vaisala RS92 and RO from June 2006 to April 2014 is within ±0.09 K/5 yr. Compared with Vaisala RS80, Vaisala RS90, and sondes from other manufacturers, the Vaisala RS92 seems to provide the most accurate RAOB temperature measurements, and these can potentially be used to construct long-term temperature climate data records (CDRs). Results from this study also demonstrate the feasibility of using RO data to correct RAOB temperature biases for different sensor types.


2016 ◽  
Vol 368 ◽  
pp. 3-6
Author(s):  
Mária Huráková ◽  
Kornel Csach ◽  
Jozef Miškuf ◽  
Alena Juríková ◽  
Štefan Demčák ◽  
...  

Nanoindentation experiments were executed on amorphous metallic ribbons made of Fe40Ni40B20, Cu47Ti35Zr11Ni6Si1 and Zr65Cu17.5Ni10Al7.5 that differ in microhardness and glass forming ability. The individual serrated plastic flow events were analyzed in a wide range of the loading rates. In the individual pop-in events of the load-displacement (P-h) curve the contributions of plastic deformation (Δhpl) were calculated depending on the loading rate and the alloy composition. It is concluded that the contribution of the serrated plastic deformation flow varies with the composition of the alloy. The highest plastic deformation for the individual pop-ins was observed for Zr-based metallic glasses.


Machines ◽  
2019 ◽  
Vol 7 (4) ◽  
pp. 67
Author(s):  
Pietro Marzaroli ◽  
Alessandro Albanetti ◽  
Edoardo Negri ◽  
Hermes Giberti ◽  
Marco Tarabini

This work describes the design and validation of an electro-mechanical excitation system for characterization of the response of the human body to multiaxial vibrations. The presented system is based on the linear delta configuration and is designed to expose standing subjects to vibration along three perpendicular axes, with an excitation bandwidth of at least 30 Hz and a maximum vibration amplitude of ±30 mm along the vertical direction and ±20 mm along the horizontal directions. The shaker characteristic dimensions are the result of numerical optimization of the inverse manipulability index; the motors and transmissions have been selected using a multibody dynamic simulation. Finite element simulations were performed to ensure that the structural resonances were outside the excitation bandwidth. Once the shaker had been manufactured, experiments were performed to verify the capability of the system in real testing conditions. The mean quadratic error between the modulus of the imposed acceleration and the measured one is between 5.7 × 10−3 and 1.4 × 10−2 m/s2 in the frequency range between 1 and 50 Hz, proving the good outcome of the design process.


2021 ◽  
Vol 250 ◽  
pp. 01003
Author(s):  
Yoshikatsu Kimoto ◽  
Kohei Kanamori ◽  
Akio Yonezu ◽  
Hiroyuki Yamada

This study evaluated the interfacial adhesive strength between aluminium alloy and epoxy resin (Al/epoxy resin) over a wide range of strain rates (loading rates). We conducted three types of tests with different loading rate, i.e., a quasi-static tensile test for the range of lower loading rate, a Split Hopkinson Bar (SHB) for the range of middle loading rate, and Laser Shock Adhesion Test (LaSAT) for the range of higher loading rate. LaSAT is a unique test of adhesion evaluation, since laser induced shock wave is employed to lead interfacial fracture. In parallel, finite element method (FEM) is conducted in order to calculate stress distribution at the interface during LaSAT. As a result, it was found that the interface between the aluminium alloy and the epoxy resin interface shows significant loading rate dependency of the adhesion strength and this tendency is very similar to that of bulk epoxy materials.


Author(s):  
Frank Z. Liang ◽  
Larry M. Palanuk ◽  
Mike Gabriel

This paper presents two simple and unique tests to extract shock-level loading limits for eutectic and lead free solders. A wide range of loading rates, from quasi-static to high speed, was applied to a through-hole-mounted anchor assembly test coupon. The high speed shock tests were conducted on a drop shock table where the impacting velocities were derived through table input adjustments. The quasi-static tests were done using controlled hydraulic linear actuator with a load cell. As would be assumed, the dynamic load to cause solder joint failure was found to increase with higher loading rate. However, at such a high loading rate range, the impact velocity did not change the load to failure. This study leads to an interesting hypothesis that at high loading rates, the solder joint strain rate may not see a significant change as observed at low rates.


Author(s):  
Runhua Zhang ◽  
Jo E. Sias ◽  
Eshan V. Dave

Aging has a significant effect on performance of asphalt materials. Reliable characterization of asphalt binder properties with aging is crucial to improving asphalt binder specifications as well as modification and formulation methods. The objective of this study is to correlate the laboratory conditioning methods with field aging using evolution of binder rheological parameters with time and pavement depth. Loose mixtures are aged in the lab (5 and 12 days aging at 95°C, and 24 h at 135°C) and recovered binder rheological properties are compared with those from different layers of field cores. The virgin binder results with 20 h pressure aging vessel (PAV) aging are also included. Binder testing is conducted using a dynamic shear rheometer with a 4 mm plate over a wide range of frequencies and temperatures. Rheological parameters calculated from the master curves, performance grade system, and binder Christensen–Anderson–Marasteanu model are used to evaluate changes with aging. The field aging gradient is evaluated, and the laboratory conditioning durations corresponding with the field aging durations at different pavement depths are calculated. The results show that 5 days of aging can simulate around 8 years of field aging (in New Hampshire) for the top 12.5 mm pavement, and 12 days’ aging can simulate approximately 20 years; 20 h PAV binder aging is not adequate to capture the long-term performance of the pavement. This study provides a way to optimize the laboratory conditioning durations and evaluate the performance of asphalt material with respect to pavement life (time) and depth (location) within the pavement structure.


2016 ◽  
Author(s):  
Shu-Peng Ho ◽  
Liang Peng ◽  
Holger Vömel

Abstract. Radiosonde observations (RAOBs) have provided the only long-term global in situ temperature measurements in the troposphere and lower stratosphere since 1958. In this study, we use consistently reprocessed Global Positioning System (GPS) radio occultation (RO) temperature data derived from COSMIC and Metop-A/GRAS missions from 2006 to 2014 to characterize the inter-seasonal and inter-annual variability of temperature biases in the lower stratosphere for different sensor types. The results show that the RAOB temperature biases for different RAOB sensor types are mainly owing to i) uncorrected solar zenith angle dependent errors, and ii) change of radiation correction. The mean daytime temperature difference (ΔT) for Vaisala RS92 is equal to 0.18 K in Australia, 0.20 K in Germany, 0.10 K in Canada, 0.13 K in England, and 0.33 K in Brazil. The mean daytime ΔT is equal to −0.06 K for Sippican, 0.71 K for VIZ-B2, 0.66 K for AVK-MRZ, and 0.18 K for Shanghai. The daytime trend of anomalies for Vaisala RS92 and RO temperature at 50 hPa is equal to 0.00 K/5 yrs over United States, −0.02 K/5 yrs over Germany, 0.17 K/5 yrs over Australia, 0.23 K/5 yrs over Canada, 0.26 K/5 yrs over England, and 0.12 K/5 yrs over Brazil, respectively. Although there still exist uncertainties for Vaisala RS92 temperature measurements over different geographical locations, the global trend of temperature anomaly between Vaisala RS92 and RO from June 2006 to April 2014 is within +/−0.09 K/5 yrs globally. Comparing with Vaisala RS80, Vaisala RS90 and sondes from other manufacturers, the Vaisala RS92 seems to provide the best RAOB temperature measurements, which can potentially be used to construct long term temperature CDRs. Results from this study also demonstrate the feasibility to use RO data to correct RAOB temperature biases for different sensor types.


1984 ◽  
Vol 106 (4) ◽  
pp. 473-479
Author(s):  
N. Urabe ◽  
A. Yoshitake ◽  
H. Kagawa

In order to investigate the mechanisms and the factors to govern the brittle fracture initiation during the fatigue crack propagation at low temperatures, fracture toughness tests under wide range of loading rates, fatigue tests at low temperatures and fracture toughness tests after having been given pre-loading were performed on steels and weld junctions. The fatigue fracture toughness Kfc was estimated as equivalent as the fracture toughness Kc under the monotonic tensile loading if they were compared at the same loading rate, since the residual stress due to the cyclic loading was less effective on the brittle fracture initiation. The calculated fatigue life based on Paris’s formula taken into consideration of the crack closure phenomena showed a good one-by-one agreement with the observed fatigue life up to the brittle fracture initiation. Therefore, a design curve was preliminarily drawn to determine the fatigue life at low temperatures.


2020 ◽  
Author(s):  
Gemma Coxon ◽  
Nans Addor ◽  
Camila Alvarez-Garreton ◽  
Hong X. Do ◽  
Keirnan Fowler ◽  
...  

<p>Large-sample hydrology (LSH) relies on data from large sets (tens to thousands) of catchments to go beyond individual case studies and derive robust conclusions on hydrological processes and models and provide the foundation for improved understanding of the link between catchment characteristics, climate and hydrological responses. Numerous LSH datasets have recently been released, covering a wide range of regions and relying on increasingly diverse data sources to characterize catchment behaviour. These datasets offer novel opportunities for open hydrology, yet they are also limited by their lack of comparability, accessibility, uncertainty estimates and characterization of human impacts.</p><p>Here, we underscore the key role of LSH datasets in open hydrologic science and highlight their potential to enhance the transparency and reproducibility of hydrological studies.  We provide a review of current LSH datasets and identify their limitations, including the current difficulties of inter-dataset comparison and limited accessibility of hydrological observations. To overcome these limitations, we propose simple guidelines alongside long-term coordinated actions for the community, which aim to standardize and automatize the creation of LSH datasets worldwide. This presentation will highlight how, by producing and using common LSH datasets, the community can increase the comparability and reproducibility of hydrological research.</p><p>This research was performed as part of the Panta Rhei Working Group on large-sample hydrology and is based on https://doi.org/10.1080/02626667.2019.1683182.</p>


Author(s):  
Bjørnar Karlsen ◽  
Kåre Lind ◽  
Helge Malmbekk ◽  
Per Ohlckers

A high-precision voltage buffer and a 10:1 resistive voltage divider have been constructed for use in ac voltage and electrical power metrology. Long-term stability of the buffer's dc response has been demonstrated by two dc sweeps performed 20 days apart, with best-fit linearized gain varying less than 1 μV/V. The absolute ac gain has been measured using a high-precision digital multimeter for 10 Hz and 1 kHz with results consistent with dc within 5 μV/V. This value agrees with the characterization of ac–dc difference using thermal converters from different producers with a variety of resistance for various voltages from 1 V to 5 V. The ac–dc difference was further characterized better than 40 μV/V for the same voltages up to 100 kHz and better than 100 μV/V for 3 V at 1 MHz. Absolute ac gain and ac–dc difference has also been measured for the voltage divider and buffer combination from 10 V to 50 V, with similar agreement up to 1 kHz. The ac–dc difference from 10 Hz to 100 kHz of this combination shows an agreement well within 30 μV/V in this entire voltage span with a total response not exceeding 125 μV/V. This make the voltage divider and buffer combination suitable for sampling electrical powers for a wide range of voltages.


Sign in / Sign up

Export Citation Format

Share Document