scholarly journals Pneumatic Artificial Muscles Based on Biomechanical Characteristics of Human Muscles

2006 ◽  
Vol 3 (3) ◽  
pp. 191-197 ◽  
Author(s):  
N. Saga ◽  
J. Nagase ◽  
T. Saikawa

This article reports the pneumatic artificial muscles based on biomechanical characteristics of human muscles. A wearable device and a rehabilitation robot that assist a human muscle should have characteristics similar to those of human muscle. In addition, since the wearable device and the rehabilitation robot should be light, an actuator with a high power to weight ratio is needed. At present, the McKibben type is widely used as an artificial muscle, but in fact its physical model is highly nonlinear. Therefore, an artificial muscle actuator has been developed in which high-strength carbon fibres have been built into the silicone tube. However, its contraction rate is smaller than the actual biological muscles. On the other hand, if an artificial muscle that contracts axially is installed in a robot as compactly as the robot hand, big installing space is required. Therefore, an artificial muscle with a high contraction rate and a tendon-driven system as a compact actuator were developed, respectively. In this study, we report on the basic structure and basic characteristics of two types of actuators.

2020 ◽  
Vol 32 (5) ◽  
pp. 885-893
Author(s):  
Naoki Saito ◽  
Daisuke Furukawa ◽  
Toshiyuki Satoh ◽  
Norihiko Saga ◽  
◽  
...  

This paper describes a semi-crouching assistive device using pneumatic artificial muscles. The goal of this device is to reduce the load on the lower back when performing work in the semi-crouching position. The load on the lower back is reduced by decreasing the compressive pressure on the lumbar disk of the lower back. This compressive pressure increases as the contraction force of the erector spine increases. Therefore, it is important to reduce the muscle activity of the erector spine. Based on the analytical result of a worker’s position model, the proposed device adopts a scheme to push the chest of the user as an appropriate assistive method. Additionally, the analytical result shows that a reduction in weight of the device is also important for decreasing the load on the lower back. Based on these results, we prototyped a lightweight semi-crouching assistive device that can generate sufficient assistive force via a pneumatic artificial muscle, which has high power to weight ratio. This device was experimentally evaluated via electromyogram of the erector spine when the user maintains a semi-crouching position. The experimental results confirmed the usefulness of this device.


2013 ◽  
Vol 460 ◽  
pp. 1-12 ◽  
Author(s):  
Alexander Hošovský ◽  
Kamil Židek

Pneumatic artificial muscles belong to a category of nonconventional pneumatic actuators that are distinctive for their high power/weight ratio, simple construction and low price and maintenance costs. As such, pneumatic artificial muscles represent an alternative type of pneumatic actuator that could replace the traditional ones in certain applications. Due to their specific construction, PAM-based systems have nonlinear characteristics which make it more difficult to design a control system with good performance. In the paper, a gray-box model (basically analytical but with certain experimental parts) of the one degree-of-freedom PAM-based actuator is derived. This model interconnects the description of pneumatic and mechanical part of the system through a set of several nonlinear differential equations and its main purpose is the design of intelligent control system in simulation environment. The model is validated in both open-loop and closed-loop mode using the measurements on real plant and the results confirm that model performance is in good agreement with the performance of real actuator.


2011 ◽  
Vol 5 (4) ◽  
pp. 544-550 ◽  
Author(s):  
Hiroki Tomori ◽  
◽  
Taro Nakamura

Robots have entered human life, and closer relationships are being formed between humans and robots. It is desirable that these robots be flexible and lightweight. With this as our goal, we have developed an artificial muscle actuator using straight-fiber-type artificial muscles derived from the McKibben-type muscles, which have excellent contraction rate and force characteristics. In this study, we compared the steady state and dynamic characteristic of straightfiber-type and McKibben-type muscles and verified the usefulness of straight-fiber-type muscles.


2009 ◽  
Vol 12 (4) ◽  
pp. 18-29
Author(s):  
Thanh Diep Cong Tu

In recent years, CPM - Continuous Passive Motion has been proved to be one of the most effective therapeutic methods for patients who have problems with motion such as spinal cord injury, ankle and knee injury, parkinson and so on. Many commercial CPM devices are found in market but all of them use motors as the main actuators. The lack of human compliance of electric actuators, which are commonly used in these machines, makes them potentially harmful to patients. An interesting alternative, to electric actuators for medical purposes, particularly promising for rehabilitation, is a pneumatic artificial muscle (PAM) actuator because of its high power/weight ratio and compliance properties. However, the highly nonlinear and hysteresis of PAM make it the challenging for design and control. In this study, a PID compensation using neural network control is studied to improve the control performance of the novel model of Knee CPM device.


2019 ◽  
Vol 10 (1) ◽  
pp. 43 ◽  
Author(s):  
Tsung-Chin Tsai ◽  
Mao-Hsiung Chiang

This study determines the practicality and feasibility of the application of pneumatic artificial muscles (PAMs) in a pneumatic therapy robotic system. The novel mechanism consists of a single actuated pneumatic artificial muscle (single-PAM) robotic lower limb that is driven by only one PAM combined with a torsion spring. Unlike most of previous studies, which used dual-actuated pneumatic artificial muscles (dual-PAMs) to drive joints, this design aims to develop a novel single-PAM for a one degree-of-freedom (1-DOF) robotic lower-limb system with the advantage of a mechanism for developing a multi-axial therapy robotic system. The lower limb robotic assisting system uses the stretching/contraction characteristics of a single-PAM and the torsion spring designed by the mechanism to realize joint position control. The joint is driven by a single-PAM controlled by a proportional pressure valve, a designed 1-DOF lower-limb robotic system, and an experimental prototype system similar to human lower limbs are established. However, the non-linear behavior, high hysteresis, low damping and time-variant characteristics for a PAM with a torsion spring still limits its controllability. In order to control the system, a fuzzy sliding mode controller (FSMC) is used to control the path tracking for the PAM for the first time. This control method prevents approximation errors, disturbances, un-modeled dynamics and ensures positioning performance for the whole system. Consequently, from the various experimental results, the control response designed by the joint torsion spring mechanism can also obtain the control response like the design of the double-PAMs mechanism, which proves that the innovative single-PAM with torsion spring mechanism design in this study can reduce the size of the overall aid mechanism and reduce the manufacturing cost, can also improve the portability and convenience required for the wearable accessory, and is more suitable for the portable rehabilitation aid system architecture.


Author(s):  
Benjamin K. S. Woods ◽  
Shane M. Boyer ◽  
Erica G. Hocking ◽  
Norman M. Wereley ◽  
Curt S. Kothera

Pneumatic artificial muscles (PAMs) are comprised of an elastomeric bladder surrounded by a braided mesh sleeve. When the bladder is inflated, the actuator may either contract or extend axially, with the direction of motion dependent on the orientation of the fibers in the braided sleeve. Contractile PAMs have excellent actuation characteristics, including high specific power, specific work, and power density. Unfortunately, extensile PAMs exhibit much reduced blocked force, and are prone to buckling under axial compressive loading. For applications in which extensile motion and compressive force are desired, the push-PAM actuator introduced here exploits the operational characteristics of a contractile PAM, but changes the direction of motion and force by employing a simple internal mechanism using no gears or pulleys. Quasi-static behavior of the push-PAM was compared to a contractile PAM for a range of operating pressures. Based on these data, the push-PAM actuator can achieve force and stroke comparable to a contractile PAM tested under the same conditions.


Author(s):  
Sunil Kumar Rajendran ◽  
Feitian Zhang

Super-coiled polymer (SCP), one of the newly-developed artificial muscles, has various advantages over traditional artificial muscles in terms of cost, flexibility and power-to-weight ratio. This paper investigates the performance of super-coiled polymer-based actuation in underwater robotics, and presents a novel design of robotic fish using antagonistic SCP actuators. Dynamic model of the robot is derived. An example robotic fish prototype is developed and used in experiments to study SCP actuation for underwater robots. Furthermore, experimental results show that using SCP actuators in robotic fish solves the challenging heat-dissipation problem at ease, thus improving the dynamic response of SCP actuation significantly. A PID controller is designed to regulate the tail flap angle of the designed robotic fish. Simulation results of the closed-loop system are presented to validate the proposed robot design and actuation approach.


2011 ◽  
Vol 186 ◽  
pp. 31-35 ◽  
Author(s):  
Fei Li ◽  
Yu Wang ◽  
He Ting Tong ◽  
Ray P.S. Han

As a skeletal muscle-like actuator, PAM possesses many unique advantages. They include compliance and high power-to-weight ratio, which make it an ideal actuator for robotic and powered exoskeleton applications. But its flexible braided mesh shell and the compressibility of air make PAM much more difficult to model and control compared to traditional actuators. In this work, the mechanical properties of the McKibben PAM produced by Festo are examined, tested and discussed. The results demonstrate the muscle-like property of PAM and its strong non-linear and hysteresis behaviors. A simple law between the areas of the hysteresis and pressure is proposed, and the relationships of the areas of the hysteresis, external load and the continuous working time are studied. Further, changing the PAM length that is smaller than 0.4 mm may lead to the “crawl” phenomenon. Finally, the empirical results can be used in compensation-based controls of the hysteresis in the McKibben PAM.


Author(s):  
Jonathon E. Slightam ◽  
Mark L. Nagurka

Abstract Fluidic braided artificial muscles have been studied for close to seventy years. Their high power-to-weight ratio and force-to-weight ratio make them a desirable actuation technology for compact and lightweight mobile manipulation. Use of hydraulics with fluidic artificial muscles has helped realize high actuation forces with new potential applications. To achieve large actuation forces produced from high internal pressure, artificial muscles operate near the limitations of their mechanical strength. Design improvements and future applications in mechanical systems will benefit from detailed theoretical analysis of the fluidic artificial muscle mechanics. This paper presents the theoretical modeling of a hydraulic artificial muscle, analysis of its mechanics, and experimental results that validate the model. A prototype is analyzed that operates at 14 MPa and can generate up to 6.3 kN of force and a displacement of 21.5 mm. This model promises to be useful for mechanical system design and model-based control.


2020 ◽  
Vol 5 (41) ◽  
pp. eaaz4239 ◽  
Author(s):  
Seyed M. Mirvakili ◽  
Douglas Sim ◽  
Ian W. Hunter ◽  
Robert Langer

Pneumatic artificial muscles have been widely used in industry because of their simple and relatively high-performance design. The emerging field of soft robotics has also been using pneumatic actuation mechanisms since its formation. However, these actuators/soft robots often require bulky peripheral components to operate. Here, we report a simple mechanism and design for actuating pneumatic artificial muscles and soft robotic grippers without the use of compressors, valves, or pressurized gas tanks. The actuation mechanism involves a magnetically induced liquid-to-gas phase transition of a liquid that assists the formation of pressure inside the artificial muscle. The volumetric expansion in the liquid-to-gas phase transition develops sufficient pressure inside the muscle for mechanical operations. We integrated this actuation mechanism into a McKibben-type artificial muscle and soft robotic arms. The untethered McKibben artificial muscle generated actuation strains of up to 20% (in 10 seconds) with associated work density of 40 kilojoules/meter3, which favorably compares with the peak strain and peak energy density of skeletal muscle. The untethered soft robotic arms demonstrated lifting objects with an input energy supply from only two Li-ion batteries.


Sign in / Sign up

Export Citation Format