scholarly journals Re-Evaluation of Acid-Base Prediction Rules in Patients with Chronic Respiratory Acidosis

2003 ◽  
Vol 10 (6) ◽  
pp. 311-315 ◽  
Author(s):  
Tereza Martinu ◽  
Dick Menzies ◽  
Sandra Dial

RATIONALE: The prediction rules for the evaluation of the acid-base status in patients with chronic respiratory acidosis, derived primarily from an experimental canine model, suggest that complete compensation should not occur. This appears to contradict frequent observations of normal or near-normal pH levels in patients with chronic hypercapnia.METHODS: Linear regression analysis was used to estimate the relationships between arterial pH, bicarbonate and partial pressure of carbon dioxide (PCO2) from 18 separate arterial blood gas measurements in 18 clinically stable outpatients with chronic hypercapnic respiratory failure from chronic obstructive lung disease, and without clinical conditions or medications likely to cause a primary metabolic alkalosis.RESULTS: The PCO2ranged from 45 mmHg to 77 mmHg, and pH ranged from 7.37 to 7.44. In only three of the arterial blood gas measurements were the pH values lower than 7.38. From the regression equations derived from these measurements, the pH decreased by 0.014 for each 10 mmHg increase in the PCO2, and the bicarbonate level increased by 5.1 mmol/L. These values are quite different from a decrease in pH of 0.03 and an increase in bicarbonate of 3.5 mmol/L predicted using the rules derived from the canine model.CONCLUSIONS: In patients with chronic stable hypercapnia, acid-base compensatory mechanisms appear to be more effective than would be predicted using the classic rules.

PLoS ONE ◽  
2021 ◽  
Vol 16 (3) ◽  
pp. e0248264
Author(s):  
Sancho Rodríguez-Villar ◽  
Paloma Poza-Hernández ◽  
Sascha Freigang ◽  
Idoia Zubizarreta-Ormazabal ◽  
Daniel Paz-Martín ◽  
...  

Background Point-of-care arterial blood gas (ABG) is a blood measurement test and a useful diagnostic tool that assists with treatment and therefore improves clinical outcomes. However, numerically reported test results make rapid interpretation difficult or open to interpretation. The arterial blood gas algorithm (ABG-a) is a new digital diagnostics solution that can provide clinicians with real-time interpretation of preliminary data on safety features, oxygenation, acid-base disturbances and renal profile. The main aim of this study was to clinically validate the algorithm against senior experienced clinicians, for acid-base interpretation, in a clinical context. Methods We conducted a prospective international multicentre observational cross-sectional study. 346 sample sets and 64 inpatients eligible for ABG met strict sampling criteria. Agreement was evaluated using Cohen’s kappa index, diagnostic accuracy was evaluated with sensitivity, specificity, efficiency or global accuracy and positive predictive values (PPV) and negative predictive values (NPV) for the prevalence in the study population. Results The concordance rates between the interpretations of the clinicians and the ABG-a for acid-base disorders were an observed global agreement of 84,3% with a Cohen’s kappa coefficient 0.81; 95% CI 0.77 to 0.86; p < 0.001. For detecting accuracy normal acid-base status the algorithm has a sensitivity of 90.0% (95% CI 79.9 to 95.3), a specificity 97.2% (95% CI 94.5 to 98.6) and a global accuracy of 95.9% (95% CI 93.3 to 97.6). For the four simple acid-base disorders, respiratory alkalosis: sensitivity of 91.2 (77.0 to 97.0), a specificity 100.0 (98.8 to 100.0) and global accuracy of 99.1 (97.5 to 99.7); respiratory acidosis: sensitivity of 61.1 (38.6 to 79.7), a specificity of 100.0 (98.8 to 100.0) and global accuracy of 98.0 (95.9 to 99.0); metabolic acidosis: sensitivity of 75.8 (59.0 to 87.2), a specificity of 99.7 (98.2 to 99.9) and a global accuracy of 97.4 (95.1 to 98.6); metabolic alkalosis sensitivity of 72.2 (56.0 to 84.2), a specificity of 95.5 (92.5 to 97.3) and a global accuracy of 93.0 (88.8 to 95.3); the four complex acid-base disorders, respiratory and metabolic alkalosis, respiratory and metabolic acidosis, respiratory alkalosis and metabolic acidosis, respiratory acidosis and metabolic alkalosis, the sensitivity, specificity and global accuracy was also high. For normal acid-base status the algorithm has PPV 87.1 (95% CI 76.6 to 93.3) %, and NPV 97.9 (95% CI 95.4 to 99.0) for a prevalence of 17.4 (95% CI 13.8 to 21.8). For the four-simple acid-base disorders and the four complex acid-base disorders the PPV and NPV were also statistically significant. Conclusions The ABG-a showed very high agreement and diagnostic accuracy with experienced senior clinicians in the acid-base disorders in a clinical context. The method also provides refinement and deep complex analysis at the point-of-care that a clinician could have at the bedside on a day-to-day basis. The ABG-a method could also have the potential to reduce human errors by checking for imminent life-threatening situations, analysing the internal consistency of the results, the oxygenation and renal status of the patient.


Author(s):  
Tom Scott ◽  
Hanna van Waart ◽  
Xavier CE Vrijdag ◽  
David Mullins ◽  
Peter Mesley ◽  
...  

Arterial blood gas (ABG) measurements at both maximum depth and at re-surfacing prior to breathing have not previously been measured during freedives conducted to extreme depth in cold open-water conditions. An elite freediver was instrumented with a left radial arterial cannula connected to two sampling syringes through a low-volume splitting device. He performed two open-water dives to 60 metres depth (197', 7 atmospheres absolute pressure) in the constant weight with fins competition format. ABG samples were drawn at 60 metres (by a mixed-gas scuba diver), and again on re-surfacing before breathing. An immersed surface static apnea, of identical length to the dives and with ABG sampling at identical times, was also performed. Both dives lasted approximately two minutes. PaO2 increased during descent from an indicative baseline of 15.8 kPa (after hyperventilation and glossopharyngeal insufflation) to 42.8 and 33.3 kPa (dives one and two), and decreased precipitously (to 8.2 and 8.6 kPa) during ascent. PaCO2 also increased from a low indicative baseline of 2.8 kPa to 6.3 and 5.1 kPa on dives one and two; an increase not explained by metabolic production of CO2 alone since PaCO2 actually decreased during ascent (to 5.2 and 4.5 kPa). Surface static apnea caused a steady decrease in PaO2 and increase in PaCO2 without the inflections provoked by depth changes. Lung compression and expansion provoke significant changes in both PaO2 and PaCO2 during rapid descent and ascent on a deep freedive. These changes generally support predictive hypotheses and previous findings in less extreme settings.


2017 ◽  
Vol 32 (2) ◽  
pp. 148-153
Author(s):  
Asifa Karamat ◽  
Shazia Awan ◽  
Muhammad Ghazanfar Hussain ◽  
Fahad Al Hameed ◽  
Faheem Butt ◽  
...  

Arterial blood gas (ABGs) analysis forms the cornerstone of emergency respiratory investigation. In many situations values obtained dictate management strategy and facilitate decision-making. It is an uncomfortable procedure for the patients and if repeated ABGs are required, consider whether less invasive measures, such as respiratory rate, pulse oximetry or capillary blood gas measurements could be used....


1988 ◽  
Vol 63 (7 Spec No) ◽  
pp. 743-747 ◽  
Author(s):  
B I McLain ◽  
J Evans ◽  
P R Dear

Sign in / Sign up

Export Citation Format

Share Document