scholarly journals Laparoscopic vs Open Ultrasound of the Liver: An in vitro Study

HPB Surgery ◽  
1996 ◽  
Vol 10 (2) ◽  
pp. 87-89 ◽  
Author(s):  
P. J. Cozzi ◽  
J. L. McCall ◽  
J. O. Jorgensen ◽  
D. L. Morris

Intra-operative contact ultrasound is a sensitive method of detecting liver tumours. The aim of this study was to compare the sensitivity of open contact ultrasound (OUS) of the liver with laparoscopic contact ultrasound (LUS). Hypoechoic “lesions” were created in 5 fresh pig livers by inserting 28 grapes via small incisions in the inferior surface. The size (range 8–25 mm) and location of each grape was recorded. Scanning was undertaken in random order by two experienced independent observers with no knowledge of the size, number or position of the lesions, using an Aloka 650 series scanner and 7.5 MHz probes. The crude sensitivity with OUS was 96% and 100% respectively for the two observers, and 92% for each with LUS. One grape was interpreted as 2 seperate grapes on LUS by one observer. Absolute sensitivity (grapes identified in the correct location) was 86% and 93% respectively with OUS and 79% for each observer with LUS.LUS was almost as sensitive as OUS in this model of hepatic metastases.

2005 ◽  
Vol 128 (2) ◽  
pp. 275-281 ◽  
Author(s):  
S. A. Atwood ◽  
F. E. Kennedy ◽  
J. H. Currier ◽  
D. W. Van Citters ◽  
J. P. Collier

The long-term success of a total knee replacement depends on the wear performance of a polyethylene bearing that separates a metal femoral component from a metal tibial tray. Although fixed bearing designs secure the polyethylene bearing to the tibial tray, mobile bearing knees allow the polyethylene to move relative to the tibial tray. This study has evaluated the wear performance of an intended articulation on the inferior surface of the LCS®-Rotating Platform mobile bearing by conducting clinically relevant tribological testing and comparing results to retrieved knee bearings. A retrieval analysis leads to the conclusion that third-body particles in the contact produce curvilinear scratches longer than the expected rotation of the knee on both the polyethylene bearing and the CoCr tibial tray. Tribological testing shows that polymethylmethacrylate (PMMA) bone cement particles produce worn surfaces most similar to retrievals. Porous-coating beads and bone debris also have the ability to damage both surfaces. Worn polyethylene surfaces from pin-on-flat tests show scratches longer than the excursion length, and “skipping marks”—pits spaced at smaller rotation intervals along a scratch—as observed in retrievals. These wear features suggest that a ratcheting mechanism, which moves the third-body particles further along the scratch with each cycle, may be responsible for the observed wear.


Planta Medica ◽  
2016 ◽  
Vol 81 (S 01) ◽  
pp. S1-S381
Author(s):  
EM Pferschy-Wenzig ◽  
K Koskinen ◽  
C Moissl-Eichinger ◽  
R Bauer

1990 ◽  
Vol 64 (03) ◽  
pp. 402-406 ◽  
Author(s):  
M D Oethinger ◽  
E Seifried

SummaryThe present in vitro study investigated dose-, time- and temperature-dependent effects of two-chain urokinase plasminogen activato(u-PA, urokinase) on normal citrated plasma. When 10 μg/ml u-PA wereadded to pooled normal plasma and incubated for 30 min at an ambient temperature (25° C), α2-antiplas-min decreased to 8% of the control value. Incubation on ice yielded a decrease to 45% of control,whereas α2-antiplasmin was fully consumed at 37° C. Fibrinogen and plasminogen fell to 46% and 39%, respectively, after a 30 min incubation at 25° C. Thrombin time prolonged to 190% of control.Various inhibitors were studied with respect to their suitability and efficacy to prevent these in vitro effects. Aprotinin exhibited a good protective effect on fibrinogen at concentrations exceeding 500 KlU/ml plasma. Its use, however, was limited due to interferences with some haemostatic assays. We could demonstrate that L-Glutamyl-L-Glycyl-L-Arginyl chloromethyl ketone (GGACK) and a specific polyclonal anti-u-PA-antibody (anti-u-PA-IgG) effectively inhibited urokinase-induced plasmin generation without interfering with haemostatic assays. The anti-u-PA-antibody afforded full protection ofα2-antiplasmin at therapeutic levels of u-PA.It is concluded that u-PA in plasma samples from patients during thrombolytic therapy may induce in vitro effects which should be prevented by the use of a suitable inhibitor such as GGACK or specific anti-u-PA-antibody.


1995 ◽  
Vol 73 (02) ◽  
pp. 219-222 ◽  
Author(s):  
Manuel Monreal ◽  
Luis Monreal ◽  
Rafael Ruiz de Gopegui ◽  
Yvonne Espada ◽  
Ana Maria Angles ◽  
...  

SummaryThe APTT has been considered the most suitable candidate to monitor the anticoagulant activity of hirudin. However, its use is hampered by problems of standardization, which make the results heavily dependent on the responsiveness of the reagent used. Our aim was to investigate if this different responsiveness of different reagents when added in vitro is to be confirmed in an ex vivo study.Two different doses of r-hirudin (CGP 39393), 0.3 mg/kg and 1 mg/kg, were administered subcutaneously to 20 New Zealand male rabbits, and the differences in prolongation of APTT 2 and 12 h later were compared, using 8 widely used commercial reagents. All groups exhibited a significant prolongation of APTT 2 h after sc administration of hirudin, both at low and high doses. But this prolongation persisted 12 h later only when the PTTa reagent (Boehringer Mannheim) was used. In general, hirudin prolonged the APTT most with the silica- based reagents.In a further study, we compared the same APTT reagents in an in vitro study in which normal pooled plasma was mixed with increasing amount of hirudin. We failed to confirm a higher sensitivity for silica- containing reagents. Thus, we conclude that subcutaneous administration of hirudin prolongs the APTT most with the silica-based reagents, but this effect is exclusive for the ex vivo model.


Sign in / Sign up

Export Citation Format

Share Document