scholarly journals A Space-Frequency Data Compression Method for Spatially Dense Laser Doppler Vibrometer Measurements

1996 ◽  
Vol 3 (2) ◽  
pp. 127-133 ◽  
Author(s):  
José Roberto de França Arruda ◽  
Sérgio Augusto Vianna do Rio ◽  
Luiz Antonio Silva Bernardes Santos

When spatially dense mobility shapes are measured with scanning laser Doppler vibrometers, it is often impractical to use phase-separation modal parameter estimation methods due to the excessive number of highly coupled modes and to the prohibitive computational cost of processing huge amounts of data. To deal with this problem, a data compression method using Chebychev polynomial approximation in the frequency domain and two-dimensional discrete Fourier series approximation in the spatial domain, is proposed in this article. The proposed space-frequency regressive approach was implemented and verified using a numerical simulation of a free-free-free-free suspended rectangular aluminum plate. To make the simulation more realistic, the mobility shapes were synthesized by modal superposition using mode shapes obtained experimentally with a scanning laser Doppler vibrometer. A reduced and smoothed model, which takes advantage of the sinusoidal spatial pattern of structural mobility shapes and the polynomial frequency-domain pattern of the mobility shapes, is obtained. From the reduced model, smoothed curves with any desired frequency and spatial resolution can he produced whenever necessary. The procedure can he used either to generate nonmodal models or to compress the measured data prior to modal parameter extraction.

2016 ◽  
Author(s):  
Navid Hasheminejad ◽  
Cedric Vuye ◽  
Wim Van den Bergh ◽  
Joris Dirckx ◽  
Jari Leysen ◽  
...  

1997 ◽  
Vol 76 (4) ◽  
pp. 213-222 ◽  
Author(s):  
Geoffrey R. Ball ◽  
Alex Huber ◽  
Richard L. Goode

This paper describes measurements of the vibratory modes of the middle ear ossicles made with a scanning laser Doppler vibrometer. Previous studies of the middle ear ossicles with single-point laser Doppler measurements have raised questions regarding the vibrational modes of the ossicular chain. Single-point analysis methods do not have the ability to measure multiple points on the ossicles and, consequently, have limited ability to simultaneously record relative phase information at these points. Using a Polytec Model PSV-100, detailed measurements of the ossicular chain have been completed in the human temporal bone model. This model, when driven with a middle ear transducer, provides detailed three-dimensional data of the vibrational patterns of the middle ear ossicles. Implications for middle ear implantable devices are discussed.


Sign in / Sign up

Export Citation Format

Share Document