scholarly journals Two-Photon Calcium Imaging of Network Activity in XFP-Expressing Neurons in the Mouse

2007 ◽  
Vol 97 (4) ◽  
pp. 3118-3125 ◽  
Author(s):  
Jennifer M. Wilson ◽  
Daniel A. Dombeck ◽  
Manuel Díaz-Ríos ◽  
Ronald M. Harris-Warrick ◽  
Robert M. Brownstone

Fluorescent protein (XFP) expression in postnatal neurons allows the anatomical and physiological investigation of identified subpopulations of interneurons with established techniques. However, the spatiotemporal pattern of activity of these XFP neurons within a network and their role in the functional output of the network are more challenging issues to investigate. Here we apply two-photon excitation laser scanning microscopy to mouse spinal cord locomotor networks and present the methodology by which calcium activity can be recorded in XFP-expressing neurons. Such activity can be studied both in relation to neighboring non-XFP neurons in a spinal cord slice preparation and in relation to functional locomotor output monitored by ventral root activity in the intact in vitro spinal cord. Thus the network properties and functional correlates with locomotion of identified populations of interneurons can be studied simultaneously.

2002 ◽  
Vol 68 (2) ◽  
pp. 901-909 ◽  
Author(s):  
Thomas R. Neu ◽  
Ute Kuhlicke ◽  
John R. Lawrence

ABSTRACT A major limitation for the use of two-proton laser scanning microscopy (2P-LSM) in biofilm and other studies is the lack of a thorough understanding of the excitation-emission responses of potential fluorochromes. In order to use 2P-LSM, the utility of various fluorochromes and probes specific for a range of biofilm constituents must be evaluated. The fluorochromes tested in this study included classical nucleic acid-specific stains, such as acridine orange (AO) and 4",6"-diamidino-2-phenylindole (DAPI), as well as recently developed stains. In addition, stains specific for biofilm extracellular polymeric substances (EPS matrix components) were tested. Two-photon excitation with a Ti/Sapphire laser was carried out at wavelengths from 760 to 900 nm in 10-nm steps. It was found that autofluorescence of phototrophic organisms (cyanobacteria and green algae) resulted in strong signals for the entire excitation range. In addition, the coenzyme F420-related autofluorescence of methanogenic bacteria could be used to obtain images of dense aggregates (excitation wavelength, 780 nm). The intensities of the emission signals for the nucleic acid-specific fluorochromes varied. For example, the intensities were similar for excitation wavelengths ranging from 780 to 900 nm for AO but were higher for a narrower range, 780 to 810 nm, for DAPI. In selective excitation, fading, multiple staining, and combined single-photon-two-photon studies, the recently developed nucleic acid-specific fluorochromes proved to be more suitable regardless of whether they are intended for living or fixed samples. Probes specific for proteins and glycoconjugates allowed two-photon imaging of polymeric biofilm constituents. Selective excitation-emission was observed for Calcofluor White M2R (780 to 800 nm) and SyproOrange (880 to 900 nm). In addition, fluor-conjugated concanavalin A lectins were examined and provided acceptable two-photon emission signals at wavelengths ranging from 780 to 800 nm. Finally, CellTracker, a fluorochrome suitable for long-term labeling of microbial eucaryote cells, was found to give strong emission at wavelengths ranging from 770 to 810 nm. If fluorochromes have the same two-photon excitation cross section, they are suitable for multiple staining and multichannel recording. Generally, if an appropriate excitation wavelength and fluorochrome were used, it was possible to obtain more highly resolved images for thick biofilm samples with two-photon laser microscopy than with conventional single-photon laser microscopy. Due to its potential for higher resolution in light-scattering tissue-like material, such as biofilms, and extremely localized excitation, 2P-LSM is a valuable addition to conventional confocal laser scanning microscopy with single-photon excitation. However, further development of the method and basic research are necessary to take full advantage of nonlinear excitation in studies of interfacial microbial ecology.


2008 ◽  
Vol 14 (6) ◽  
pp. 492-506 ◽  
Author(s):  
John A. Scherschel ◽  
Michael Rubart

AbstractTwo-photon excitation microscopy has become the standard technique for high resolution deep tissue and intravital imaging. It provides intrinsic three-dimensional resolution in combination with increased penetration depth compared to single-photon confocal microscopy. This article will describe the basic physical principles of two-photon excitation and will review its multiple applications to cardiovascular imaging, including second harmonic generation and fluorescence laser scanning microscopy. In particular, the capability and limitations of multiphoton microscopy to assess functional heterogeneity on a cellular scale deep within intact, Langendorff-perfused hearts are demonstrated. It will also discuss the use of two-photon excitation-induced release of caged compounds for the study of intracellular calcium signaling and intercellular dye transfer.


1999 ◽  
Vol 5 (S2) ◽  
pp. 1060-1061
Author(s):  
J. M. Squirrell ◽  
D. L. Wokosin ◽  
B. D. Bavister ◽  
J. G. White

A major challenge for fluorescence imaging of living cells is maintaining viability during and following prolonged exposure to excitation illumination, especially when imaging over hours or even days, as when studying mammalian embryonic development. The use of specific fluorescently labeled components in living embryos promises to reveal the roles of organelles and molecules in a native and reproducible context. However, to gain a thorough understanding of dynamic biological systems, events of interest must be recorded as they occur, while limiting perturbations caused by the observation technique. Therefore, establishing long-term fluorescence imaging methods that maintain viability is critical for advancing our understanding of cell and developmental biology.One promising technique for imaging living cells is two photon laser scanning microscopy (TPLSM). The lower energy per photon and the restriction of fluorophore excitation to the imaged focal plane should reduce the total photodamage to thick specimens when compared to conventional laser scanning confocal microscopy (LSCM).


Author(s):  
David W. Piston ◽  
James H. Strickler ◽  
Watt W. Webb

The non-linear optical technique of two-photon excitation of fluorescence and photochemical reactions makes possible new applications that are not possible using linear one-photon excitation in laser scanning confocal microscopy. The two-photon excitation effect arises from the simultaneous absorption of two red photons, which causes the transition to an excited electronic state with its normal absorption in the ultraviolet. In our fluorescence experiments, this excited state is the same singlet state, S1, that is populated during a conventional fluorescence experiment, and thus exhibits the same emission properties (e.g. wavelength shifts, environmental sensitivity) that are observed in typical biological microscopy studies. Likewise, photochemical reactions such as light induced polymerization and photolytic uncaging that are normally catalyzed by UV light can be generated using two-photon excitation. In practice, twophoton excitation is made possible by the very high local instantaneous intensity that is provided by a combination of the diffraction limited focusing in the microscope and the temporal concentration of a subpicosecond mode-locked laser.


Sign in / Sign up

Export Citation Format

Share Document