Time-Frequency Representation of Inspiratory Motor Output in Anesthetized C57BL/6 Mice In Vivo

2005 ◽  
Vol 93 (3) ◽  
pp. 1762-1775 ◽  
Author(s):  
Marvin H. O'Neal ◽  
Evan T. Spiegel ◽  
Ki H. Chon ◽  
Irene C. Solomon

Inspiratory motor discharges, in addition to long-time-scale rhythmic oscillatory bursting, exhibit short-time-scale rhythmic oscillations that have been identified, and subsequently characterized, using power spectral analyses [predominantly fast-Fourier transforms (FFT)]. These analyses assume that the signal being analyzed is stationary; however, this is not the case for most biological signals, which exhibit varying degrees of nonstationarity. To overcome this limitation, time-frequency methods, which provide not only the frequency content but also information regarding the timing of these fast rhythmic oscillations (i.e., dynamics of spectral activity), should be used. Thus this study was performed to investigate the dynamic or time-varying features of spectral activity in inspiratory motor output. Both conventional time-invariant and time-frequency (time-varying) spectral analysis methods were performed on recordings of diaphragm EMG, phrenic nerve, and hypoglossal nerve discharges obtained from spontaneously breathing urethan-anesthetized adult C57BL/6 mice. Conventional time-invariant spectral analysis using a FFT algorithm revealed three dominant peaks in the power spectrum, which were located at 1) 20–46, 2) 83–149, and 3) 177–227 Hz. Time-frequency spectral analysis using a generalized time-frequency representation (TFR) with the smoothed pseudo-Wigner-Ville distribution (SPWD) kernel confirmed the general location of these spectral peaks, identified additional spectral peaks within the frequency ranges described above, and revealed a time-dependent expression of spectral activity within the inspiratory burst for each of the frequency ranges. Furthermore, this method revealed that 1) little or no spectral activity occurs during the initial portion of the inspiratory burst in any of the frequency ranges identified, 2) transient oscillations in the magnitude of spectral power exist where spectral activity occurs, and 3) total spectral power exhibits an augmenting pattern over the course of the inspiratory burst. These data, which provide the first description of spectral content in inspiratory motor discharges in adult mice, show that both time-invariant and time-varying spectral analysis methods are capable of identifying short-time-scale rhythmic oscillations in inspiratory motor discharge (as expected); however, the dynamic (i.e., timing) features of this oscillatory activity can only be obtained using the time-frequency method. We suggest that time-frequency methods, such as the SPWD, should be used in future studies examining short-time-scale (fast) rhythmic oscillations in inspiratory motor discharges, because additional insight into the neural control mechanisms that participate in inspiratory-phase neuronal and motoneuronal synchronization may be obtained.

2016 ◽  
Vol 311 (3) ◽  
pp. R582-R591 ◽  
Author(s):  
Hugo F. Posada-Quintero ◽  
John P. Florian ◽  
Álvaro D. Orjuela-Cañón ◽  
Ki H. Chon

Time-domain indices of electrodermal activity (EDA) have been used as a marker of sympathetic tone. However, they often show high variation between subjects and low consistency, which has precluded their general use as a marker of sympathetic tone. To examine whether power spectral density analysis of EDA can provide more consistent results, we recently performed a variety of sympathetic tone-evoking experiments (43). We found significant increase in the spectral power in the frequency range of 0.045 to 0.25 Hz when sympathetic tone-evoking stimuli were induced. The sympathetic tone assessed by the power spectral density of EDA was found to have lower variation and more sensitivity for certain, but not all, stimuli compared with the time-domain analysis of EDA. We surmise that this lack of sensitivity in certain sympathetic tone-inducing conditions with time-invariant spectral analysis of EDA may lie in its inability to characterize time-varying dynamics of the sympathetic tone. To overcome the disadvantages of time-domain and time-invariant power spectral indices of EDA, we developed a highly sensitive index of sympathetic tone, based on time-frequency analysis of EDA signals. Its efficacy was tested using experiments designed to elicit sympathetic dynamics. Twelve subjects underwent four tests known to elicit sympathetic tone arousal: cold pressor, tilt table, stand test, and the Stroop task. We hypothesize that a more sensitive measure of sympathetic control can be developed using time-varying spectral analysis. Variable frequency complex demodulation, a recently developed technique for time-frequency analysis, was used to obtain spectral amplitudes associated with EDA. We found that the time-varying spectral frequency band 0.08–0.24 Hz was most responsive to stimulation. Spectral power for frequencies higher than 0.24 Hz were determined to be not related to the sympathetic dynamics because they comprised less than 5% of the total power. The mean value of time-varying spectral amplitudes in the frequency band 0.08–0.24 Hz were used as the index of sympathetic tone, termed TVSymp. TVSymp was found to be overall the most sensitive to the stimuli, as evidenced by a low coefficient of variation (0.54), and higher consistency (intra-class correlation, 0.96) and sensitivity (Youden's index > 0.75), area under the receiver operating characteristic (ROC) curve (>0.8, accuracy > 0.88) compared with time-domain and time-invariant spectral indices, including heart rate variability.


2008 ◽  
Vol 130 (2) ◽  
Author(s):  
Yoonchan Oh ◽  
C. Steve Suh ◽  
Hung-Jue Sue

The demand for higher clock speed and larger current magnitude in high-performance flip chip packaging configurations of small footprint has raised the concern over rapid thermal transients and large thermal spatial gradients that could severely compromise package performance. This paper explores coupled electrical-thermal-mechanical multiphysics to evaluate the concern and to establish the knowledge base necessary for improving flip chip reliability. It is found that within the first few hundreds of nanoseconds after power-on, there are fast-attenuating, dispersive stress waves of extremely high frequency propagating in the package. The concepts of high cycle fatigue, power density, and joint time-frequency analysis are employed to characterize the waves along with the various damage modes resulting from the propagation of these short-lived dynamical disturbances in bulk materials and along bimaterial interfaces. A qualitative measure for failure is developed to evaluate the extent of damage inflicted by short-time wave motion. Damages identified in this study are in agreement with physical failure modes commonly seen in industry, thus implying that micron scale cracks or interfacial adhesion flaws initiated at the short-time scale would be further propagated by the coefficient of thermal expansion induced thermal stresses at the long-time scale and result in eventual electrical disruptions.


1993 ◽  
Vol 21 (2) ◽  
pp. 196-201
Author(s):  
Søren Achim Nielsen ◽  
Thomas Hougaard

An alternative test is presented, in which algal cultures are used for testing toxic substances. This test system is based on variations in the size distribution of cells in test cultures as a measurement of growth. Thus, inhibition of mitotic activity is used as a measurement for toxic effects. The test can be performed on a short time-scale and is very sensitive to even weak toxic doses.


1996 ◽  
Vol 32 (2) ◽  
pp. 212-221 ◽  
Author(s):  
Eglee Gomez Fermin ◽  
Francisco G. Figueiras ◽  
Belen Arbones ◽  
Maria Luisa Villarino

Sign in / Sign up

Export Citation Format

Share Document