scholarly journals Translational aspects of rectal evoked potentials: a comparative study in rats and humans

2013 ◽  
Vol 305 (2) ◽  
pp. G119-G128 ◽  
Author(s):  
Thomas Dahl Nissen ◽  
Christina Brock ◽  
Carina Graversen ◽  
Steven J. Coen ◽  
Leif Hultin ◽  
...  

Inconsistencies between species has stunted the progress of developing new analgesics. To increase the success of translating results between species, improved comparable models are required. Twelve rats received rectal balloon distensions on 2 different days separated by 24.3 (SD 24.6) days. Rectal balloon distensions were also performed in 18 humans (mean age: 34 yr; range: 21–56 yr; 12 men) on two separate occasions, separated by 9.3 (SD 5.5) days. In rats, cerebral evoked potentials (CEPs) were recorded by use of implanted skull-electrodes to distension pressure of 80 mmHg. In humans surface electrodes and individualized pressure, corresponding to pain detection threshold, were used. Comparison of morphology was assessed by wavelet analysis. Within- and between-day reproducibility was assessed in terms of latencies, amplitudes, and frequency content. In rats CEPs showed triphasic morphology. No differences in latencies, amplitudes, and power distribution were seen within or between days (all P ≥ 0.5). Peak-to-peak amplitude between the first positive and negative potential were the most reproducible characteristic within and between days (evaluated by intraclass correlation coefficients, ICC) (ICC = 0.99 and ICC = 9.98, respectively). In humans CEPs showed a triphasic morphology. No differences in latencies, amplitudes, or power distribution were seen within or between days (all P ≥ 0.2). Latency to the second negative potential (ICC = 0.98) and the second positive potential (ICC = 0.95) was the most reproducible characteristic within and between days. A unique and reliable translational platform was established assessing visceral sensitivity in rats and humans, which may improve the translational process of developing new drugs targeting visceral pain.

2012 ◽  
Vol 3 (3) ◽  
pp. 186
Author(s):  
Thomas Dahl Nissen ◽  
Carina Graversen ◽  
Steven Coen ◽  
Leif Hultin ◽  
Qasim Aziz ◽  
...  

AbstractBackgroundIn recent years only few novel drugs targeting visceral pain have been developed. This lack of success may be explained by animal models having poor predictive value. To increase the success of translating results from animals to humans there is a demand for comparable test models. The aim was to establish a comparable and reliable translational model to evoke mechanical rectal pain in rats and humans.MethodsMechanical rectal rapid balloon distension was done on two different days in 12 rats (separated by 24.3 ± 7.1 days) and 18 humans (separated by 9.3 ± 1.3 days). Evoked potentials were recorded from permanently implanted skull-electrodes in rats, at stimulation pressure of 80 mmHg and duration of 100 ms. In human surface electrodes and individualized pressure, corresponding to the pain detection threshold, lasting 150 ms, were used. Within- and between days reproducibility were assessed in terms of latencies, amplitudes and frequency content.ResultsIn both rats and humans evoked potentials with tri-phasic morphology were recorded. No differences in latencies, amplitudes and power distribution were seen within or between days (all F ≤ 2.0; all P ≥ 0.2). The analyses of the EPs revealed peak-to-peak amplitude as the most reproducible parameter within (ICC ≥ 0.84) and between (ICC ≥ 0.70) days, seen across both species. The spectral analyses showed that the EEG power was distributed mainly in the delta and theta bands. The main power in rats was contained in the theta band (45%), whereas humans had the predominant power in the delta band (46%).ConclusionA unique visceral translational platform was established to reliably assess neurophysiologic response to rapid balloon distension in rats and humans. The model provides an approach to study basic and clinical pain as well as pharmacological intervention.


Pain Medicine ◽  
2019 ◽  
Vol 21 (4) ◽  
pp. 736-746 ◽  
Author(s):  
Jan Rosner ◽  
Paulina Simonne Scheuren ◽  
Stephanie Anja Stalder ◽  
Armin Curt ◽  
Michèle Hubli

Abstract Objective Pinprick evoked potentials (PEPs) represent a novel tool to assess the functional integrity of mechano-nociceptive pathways with a potential toward objectifying sensory deficits and gain seen in neurological disorders. The aim of the present study was to evaluate the feasibility and reliability of PEPs with respect to age, stimulation site, and skin type. Methods Electroencephalographic responses evoked by two pinprick stimulation intensities (128 mN and 256 mN) applied at three sites (hand dorsum, palmar digit II, and foot dorsum) were recorded in 30 healthy individuals. Test–retest reliability was performed for the vertex negative–positive complex amplitudes, N-latencies, and pain ratings evoked by the 256mN stimulation intensity. Results Feasibility of PEP acquisition was demonstrated across age groups, with higher proportions of evoked potentials (>85%) for the 256mN stimulation intensity. Reliability analyses, that is, Bland-Altman and intraclass correlation coefficients, revealed poor to excellent reliability upon retest depending on the stimulation sites. Conclusions This study highlights the reliability of PEP acquisition from cervical and lumbar segments across clinically representative age groups. Future methodological improvements might further strengthen PEP reliability in order to complement clinical neurophysiology of sensory nerve fibers by a more specific assessment of mechano-nociceptive pathways. Beyond looking at sensory deficits, PEPs may also become applicable to revealing signs of central sensitization, complementing the clinical assessment of mechanical hyperalgesia.


1991 ◽  
Vol 34 (5) ◽  
pp. 989-999 ◽  
Author(s):  
Stephanie Shaw ◽  
Truman E. Coggins

This study examines whether observers reliably categorize selected speech production behaviors in hearing-impaired children. A group of experienced speech-language pathologists was trained to score the elicited imitations of 5 profoundly and 5 severely hearing-impaired subjects using the Phonetic Level Evaluation (Ling, 1976). Interrater reliability was calculated using intraclass correlation coefficients. Overall, the magnitude of the coefficients was found to be considerably below what would be accepted in published behavioral research. Failure to obtain acceptably high levels of reliability suggests that the Phonetic Level Evaluation may not yet be an accurate and objective speech assessment measure for hearing-impaired children.


2018 ◽  
Vol 21 (2) ◽  
pp. 125-137
Author(s):  
Jolanta Stasiak ◽  
Marcin Koba ◽  
Marcin Gackowski ◽  
Tomasz Baczek

Aim and Objective: In this study, chemometric methods as correlation analysis, cluster analysis (CA), principal component analysis (PCA), and factor analysis (FA) have been used to reduce the number of chromatographic parameters (logk/logkw) and various (e.g., 0D, 1D, 2D, 3D) structural descriptors for three different groups of drugs, such as 12 analgesic drugs, 11 cardiovascular drugs and 36 “other” compounds and especially to choose the most important data of them. Material and Methods: All chemometric analyses have been carried out, graphically presented and also discussed for each group of drugs. At first, compounds’ structural and chromatographic parameters were correlated. The best results of correlation analysis were as follows: correlation coefficients like R = 0.93, R = 0.88, R = 0.91 for cardiac medications, analgesic drugs, and 36 “other” compounds, respectively. Next, part of molecular and HPLC experimental data from each group of drugs were submitted to FA/PCA and CA techniques. Results: Almost all results obtained by FA or PCA, and total data variance, from all analyzed parameters (experimental and calculated) were explained by first two/three factors: 84.28%, 76.38 %, 69.71% for cardiovascular drugs, for analgesic drugs and for 36 “other” compounds, respectively. Compounds clustering by CA method had similar characteristic as those obtained by FA/PCA. In our paper, statistical classification of mentioned drugs performed has been widely characterized and discussed in case of their molecular structure and pharmacological activity. Conclusion: Proposed QSAR strategy of reduced number of parameters could be useful starting point for further statistical analysis as well as support for designing new drugs and predicting their possible activity.


Author(s):  
Marcos A Soriano ◽  
G Gregory Haff ◽  
Paul Comfort ◽  
Francisco J Amaro-Gahete ◽  
Antonio Torres-González ◽  
...  

The aims of this study were to (I) determine the differences and relationship between the overhead press and split jerk performance in athletes involved in weightlifting training, and (II) explore the magnitude of these differences in one-repetition maximum (1RM) performances between sexes. Sixty-one men (age: 30.4 ± 6.7 years; height: 1.8 ± 0.5 m; body mass 82.5 ± 8.5 kg; weightlifting training experience: 3.7 ± 3.5 yrs) and 21 women (age: 29.5 ± 5.2 yrs; height: 1.7 ± 0.5 m; body mass: 62.6 ± 5.7 kg; weightlifting training experience: 3.0 ± 1.5 yrs) participated. The 1RM performance of the overhead press and split jerk were assessed for all participants, with the overhead press assessed on two occasions to determine between-session reliability. The intraclass correlation coefficients (ICC) and 95% confidence intervals showed a high reliability for the overhead press ICC = 0.98 (0.97 – 0.99). A very strong correlation and significant differences were found between the overhead press and split jerk 1RM performances for all participants (r = 0.90 [0.93 – 0.85], 60.2 ± 18.3 kg, 95.7 ± 29.3 kg, p ≤ 0.001). Men demonstrated stronger correlations between the overhead press and split jerk 1RM performances (r = 0.83 [0.73-0.90], p ≤ 0.001) compared with women (r = 0.56 [0.17-0.80], p = 0.008). These results provide evidence that 1RM performance of the overhead press and split jerk performance are highly related, highlighting the importance of upper-limb strength in the split jerk maximum performance.


Nutrients ◽  
2021 ◽  
Vol 13 (4) ◽  
pp. 1163
Author(s):  
Suzana Shahar ◽  
Mohd Razif Shahril ◽  
Noraidatulakma Abdullah ◽  
Boekhtiar Borhanuddin ◽  
Mohd Arman Kamaruddin ◽  
...  

Measuring dietary intakes in a multi-ethnic and multicultural setting, such as Malaysia, remains a challenge due to its diversity. This study aims to develop and evaluate the relative validity of an interviewer-administered food frequency questionnaire (FFQ) in assessing the habitual dietary exposure of The Malaysian Cohort (TMC) participants. We developed a nutrient database (with 203 items) based on various food consumption tables, and 803 participants were involved in this study. The output of the FFQ was then validated against three-day 24-h dietary recalls (n = 64). We assessed the relative validity and its agreement using various methods, such as Spearman’s correlation, weighed Kappa, intraclass correlation coefficient (ICC), and Bland–Altman analysis. Spearman’s correlation coefficient ranged from 0.24 (vitamin C) to 0.46 (carbohydrate), and almost all nutrients had correlation coefficients above 0.3, except for vitamin C and sodium. Intraclass correlation coefficients ranged from −0.01 (calcium) to 0.59 (carbohydrates), and weighted Kappa exceeded 0.4 for 50% of nutrients. In short, TMC’s FFQ appears to have good relative validity for the assessment of nutrient intake among its participants, as compared to the three-day 24-h dietary recalls. However, estimates for iron, vitamin A, and vitamin C should be interpreted with caution.


Dysphagia ◽  
2021 ◽  
Author(s):  
Sofie Albinsson ◽  
Lisa Tuomi ◽  
Christine Wennerås ◽  
Helen Larsson

AbstractThe lack of a Swedish patient-reported outcome instrument for eosinophilic esophagitis (EoE) has limited the assessment of the disease. The aims of the study were to translate and validate the Eosinophilic Esophagitis Activity Index (EEsAI) to Swedish and to assess the symptom severity of patients with EoE compared to a nondysphagia control group. The EEsAI was translated and adapted to a Swedish cultural context (S-EEsAI) based on international guidelines. The S-EEsAI was validated using adult Swedish patients with EoE (n = 97) and an age- and sex-matched nondysphagia control group (n = 97). All participants completed the S-EEsAI, the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire-Oesophageal Module 18 (EORTC QLQ-OES18), and supplementary questions regarding feasibility and demographics. Reliability and validity of the S-EEsAI were evaluated by Cronbach’s alpha and Spearman correlation coefficients between the domains of the S-EEsAI and the EORTC QLQ-OES18. A test–retest analysis of 29 patients was evaluated through intraclass correlation coefficients. The S-EEsAI had sufficient reliability with Cronbach’s alpha values of 0.83 and 0.85 for the “visual dysphagia question” and the “avoidance, modification and slow eating score” domains, respectively. The test–retest reliability was sufficient, with good to excellent intraclass correlation coefficients (0.60–0.89). The S-EEsAI domains showed moderate correlation to 6/10 EORTC QLQ-OES18 domains, indicating adequate validity. The patient S-EEsAI results differed significantly from those of the nondysphagia controls (p < 0.001). The S-EEsAI appears to be a valid and reliable instrument for monitoring adult patients with EoE in Sweden.


Author(s):  
Jens Sörensen ◽  
Jonny Nordström ◽  
Tomasz Baron ◽  
Stellan Mörner ◽  
Sven-Olof Granstam ◽  
...  

Abstract Aim To develop a method for diagnosing left ventricular (LV) hypertrophy from cardiac perfusion 15O-water positron emission tomography (PET). Methods We retrospectively pooled data from 139 subjects in four research cohorts. LV remodeling patterns ranged from normal to severe eccentric and concentric hypertrophy. 15O-water PET scans (n = 197) were performed with three different PET devices. A low-end scanner (66 scans) was used for method development, and remaining scans with newer devices for a blinded evaluation. Dynamic data were converted into parametric images of perfusable tissue fraction for semi-automatic delineation of the LV wall and calculation of LV mass (LVM) and septal wall thickness (WT). LVM and WT from PET were compared to cardiac magnetic resonance (CMR, n = 47) and WT to 2D-echocardiography (2DE, n = 36). PET accuracy was tested using linear regression, Bland–Altman plots, and ROC curves. Observer reproducibility were evaluated using intraclass correlation coefficients. Results High correlations were found in the blinded analyses (r ≥ 0.87, P < 0.0001 for all). AUC for detecting increased LVM and WT (> 12 mm and > 15 mm) was ≥ 0.95 (P < 0.0001 for all). Reproducibility was excellent (ICC ≥ 0.93, P < 0.0001). Conclusion 15O-water PET might detect LV hypertrophy with high accuracy and precision.


Author(s):  
Igor Junio de Oliveira Custódio ◽  
Gibson Moreira Praça ◽  
Leandro Vinhas de Paula ◽  
Sarah da Glória Teles Bredt ◽  
Fabio Yuzo Nakamura ◽  
...  

This study aimed to analyze the intersession reliability of global positioning system (GPS-based) distances and accelerometer-based (acceleration) variables in small-sided soccer games (SSG) with and without the offside rule, as well as compare variables between the tasks. Twenty-four high-level U-17 soccer athletes played 3 versus 3 (plus goalkeepers) SSG in two formats (with and without the offside rule). SSG were performed on eight consecutive weeks (4 weeks for each group), twice a week. The physical demands were recorded using a GPS with an embedded triaxial accelerometer. GPS-based variables (total distance, average speed, and distances covered at different speeds) and accelerometer-based variables (Player Load™, root mean square of the acceleration recorded in each movement axis, and the root mean square of resultant acceleration) were calculated. Results showed that the inclusion of the offside rule reduced the total distance covered (large effect) and the distances covered at moderate speed zones (7–12.9 km/h – moderate effect; 13–17.9 km/h – large effect). In both SSG formats, GPS-based variables presented good to excellent reliability (intraclass correlation coefficients – ICC > 0.62) and accelerometer-based variables presented excellent reliability (ICC values > 0.89). Based on the results of this study, the offside rule decreases the physical demand of 3 versus 3 SSG and the physical demands required in these SSG present high intersession reliability.


Author(s):  
Jodie E. Chapman ◽  
Betina Gardner ◽  
Jennie Ponsford ◽  
Dominique A. Cadilhac ◽  
Renerus J. Stolwyk

Abstract Objective: Neuropsychological assessment via videoconference could assist in bridging service access gaps due to geographical, mobility, or infection control barriers. We aimed to compare performances on neuropsychological measures across in-person and videoconference-based administrations in community-based survivors of stroke. Method: Participants were recruited through a stroke-specific database and community advertising. Stroke survivors were eligible if they had no upcoming neuropsychological assessment, concurrent neurological and/or major psychiatric diagnoses, and/or sensory, motor, or language impairment that would preclude standardised assessment. Thirteen neuropsychological measures were administered in-person and via videoconference in a randomised crossover design (2-week interval). Videoconference calls were established between two laptop computers, facilitated by Zoom. Repeated-measures t tests, intraclass correlation coefficients (ICCs), and Bland–Altman plots were used to compare performance across conditions. Results: Forty-eight participants (26 men; M age = 64.6, SD = 10.1; M time since stroke = 5.2 years, SD = 4.0) completed both sessions on average 15.8 (SD = 9.7) days apart. For most measures, the participants did not perform systematically better in a particular condition, indicating agreement between administration methods. However, on the Hopkins Verbal Learning Test – Revised, participants performed poorer in the videoconference condition (Total Recall Mdifference = −2.11). ICC estimates ranged from .40 to .96 across measures. Conclusions: This study provides preliminary evidence that in-person and videoconference assessment result in comparable scores for most neuropsychological tests evaluated in mildly impaired community-based survivors of stroke. This preliminary evidence supports teleneuropsychological assessment to address service gaps in stroke rehabilitation; however, further research is needed in more diverse stroke samples.


Sign in / Sign up

Export Citation Format

Share Document