Pyrolyzed Photoresist Electrodes for Integration in Microfluidic Chips for Transmitter Detection from Biological Cells

2013 ◽  
Vol 2 (5) ◽  
pp. B5-B7 ◽  
Author(s):  
S. T. Larsen ◽  
A. Argyraki ◽  
L. Amato ◽  
S. Tanzi ◽  
S. S. Keller ◽  
...  
PIERS Online ◽  
2009 ◽  
Vol 5 (3) ◽  
pp. 251-255 ◽  
Author(s):  
Hsin-Hung Li ◽  
Jen-Yu Jao ◽  
Ming-Kun Chen ◽  
Ling-Sheng Jang ◽  
Yi-Chu Hsu

2016 ◽  
Vol 34 (11) ◽  
pp. 1043
Author(s):  
Wei YAN ◽  
Deshun XU ◽  
Yunfeng ZHA ◽  
Xiaofang WU

2019 ◽  
Vol 35 (6) ◽  
pp. 87-90
Author(s):  
S.V. Nikulin ◽  
V.A. Petrov ◽  
D.A. Sakharov

The real-time monitoring of electric capacitance (impedance spectroscopy) allowed obtaining evidence that structures which look like intestinal villi can be formed during the cultivation under static conditions as well as during the cultivation in microfluidic chips. It was shown in this work via transcriptome analysis that the Hh signaling pathway is involved in the formation of villus-like structures in vitro, which was previously shown for their formation in vivo. impedance spectroscopy, intestine, villi, electric capacitance, Hh The study was funded by the Russian Science Foundation (Project 16-19-10597).


2014 ◽  
Vol 11 (2) ◽  
pp. 116-120 ◽  
Author(s):  
Yung-Sheng Lin ◽  
Ming-Yuan-Lee ◽  
Chih-Hui Yang ◽  
Keng-Shiang Huang

2019 ◽  
Vol 73 (8) ◽  
pp. 893-901
Author(s):  
Sinead J. Barton ◽  
Bryan M. Hennelly

Cosmic ray artifacts may be present in all photo-electric readout systems. In spectroscopy, they present as random unidirectional sharp spikes that distort spectra and may have an affect on post-processing, possibly affecting the results of multivariate statistical classification. A number of methods have previously been proposed to remove cosmic ray artifacts from spectra but the goal of removing the artifacts while making no other change to the underlying spectrum is challenging. One of the most successful and commonly applied methods for the removal of comic ray artifacts involves the capture of two sequential spectra that are compared in order to identify spikes. The disadvantage of this approach is that at least two recordings are necessary, which may be problematic for dynamically changing spectra, and which can reduce the signal-to-noise (S/N) ratio when compared with a single recording of equivalent duration due to the inclusion of two instances of read noise. In this paper, a cosmic ray artefact removal algorithm is proposed that works in a similar way to the double acquisition method but requires only a single capture, so long as a data set of similar spectra is available. The method employs normalized covariance in order to identify a similar spectrum in the data set, from which a direct comparison reveals the presence of cosmic ray artifacts, which are then replaced with the corresponding values from the matching spectrum. The advantage of the proposed method over the double acquisition method is investigated in the context of the S/N ratio and is applied to various data sets of Raman spectra recorded from biological cells.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Dezhi Feng ◽  
Jing Su ◽  
Yi Xu ◽  
Guifang He ◽  
Chenguang Wang ◽  
...  

AbstractProstate-specific antigen (PSA) is the most widely used biomarker for the early diagnosis of prostate cancer. Existing methods for PSA detection are burdened with some limitations and require improvement. Herein, we developed a novel microfluidic–electrochemical (μFEC) detection system for PSA detection. First, we constructed an electrochemical biosensor based on screen-printed electrodes (SPEs) with modification of gold nanoflowers (Au NFs) and DNA tetrahedron structural probes (TSPs), which showed great detection performance. Second, we fabricated microfluidic chips by DNA TSP-Au NF-modified SPEs and a PDMS layer with designed dense meandering microchannels. Finally, the μFEC detection system was achieved based on microfluidic chips integrated with the liquid automatic conveying unit and electrochemical detection platform. The μFEC system we developed acquired great detection performance for PSA detection in PBS solution. For PSA assays in spiked serum samples of the μFEC system, we obtained a linear dynamic range of 1–100 ng/mL with a limit of detection of 0.2 ng/mL and a total reaction time <25 min. Real serum samples of prostate cancer patients presented a strong correlation between the “gold-standard” chemiluminescence assays and the μFEC system. In terms of operation procedure, cost, and reaction time, our method was superior to the current methods for PSA detection and shows great potential for practical clinical application in the future.


Langmuir ◽  
2020 ◽  
Vol 36 (44) ◽  
pp. 13364-13370
Author(s):  
Zhengping Tan ◽  
Zaiyan Hou ◽  
Ke Wang ◽  
Yuce Li ◽  
Lianbin Zhang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document