Field of view control for closed-loop visually-guided motion

Author(s):  
William S. Gribble
2018 ◽  
Vol 2018 ◽  
pp. 1-13
Author(s):  
Zhi-ming Song ◽  
Zhong-quan Qu

To expand field of view (FOV) of telescope, the method of special scanning often is used, but, for some telescopes with special structure in optics and machine, the conventional scanning methods are unsuitable. This paper proposes a novel scanning method based on autoguiding system so as to expand the FOV of fiber array solar optical telescope (FASOT) in possession of the special structure in optics and machine. Meanwhile, corresponding experiments are conducted in the FASOT prototype, FASOT-1B, in order to demonstrate that, for both FASOT and FASOT-1B, the proposed scanning method is feasible. First of all, on the basis of the software and hardware characteristics of FASOT and FASOT-1B, the three key technologies related to the proposed scanning method are described: quickly locating and pointing the first scanning step, the closed-loop controlling of multistep scanning, and the disturbance suppression of every scanning step based on Kalman filter. Afterwards, experiments are conducted and corresponding results show that the proposed scanning method is robust for the random disturbances forced on every scanning step and able to meet the scanning requirement of both FASOT and FASOT-1B .


2017 ◽  
Vol 05 (01) ◽  
pp. 1-17 ◽  
Author(s):  
Geoff Fink ◽  
Hui Xie ◽  
Alan F. Lynch ◽  
Martin Jagersand

This paper presents a dynamic image-based visual servoing (IBVS) control law for a quadrotor unmanned aerial vehicle (UAV) equipped with a single fixed on-board camera. The motion control problem is to regulate the relative position and yaw of the vehicle to a moving planar target located within the camera’s field of view. The control law is termed dynamic as it’s based on the dynamics of the vehicle. To simplify the kinematics and dynamics, the control law relies on the notion of a virtual camera and image moments as visual features. The convergence of the closed-loop is proven to be globally asymptotically stable for a horizontal target. In the case of nonhorizontal targets, we modify the control using a homography decomposition. Experimental and simulation results demonstrate the control law’s performance.


Robotica ◽  
2005 ◽  
Vol 23 (4) ◽  
pp. 409-418 ◽  
Author(s):  
Kemal Berk Yesin ◽  
Bradley J. Nelson

We present a visual feedback method for closed loop control of automated microassembly. A CAD model based multi-camera visual tracking system that is well suited for flexible automation and assembly of complex 3D geometries was developed. The system is capable of providing six degree-of-freedom pose feedback on the observed micro-components in real-time (30 Hz). Using CAD models of the observed objects, a complete description of the observed scene, including the effect of occlusions, is available and dependence on distinctive visual features such as fudicial marks is avoided.


1994 ◽  
Vol 144 ◽  
pp. 593-596
Author(s):  
O. Bouchard ◽  
S. Koutchmy ◽  
L. November ◽  
J.-C. Vial ◽  
J. B. Zirker

AbstractWe present the results of the analysis of a movie taken over a small field of view in the intermediate corona at a spatial resolution of 0.5“, a temporal resolution of 1 s and a spectral passband of 7 nm. These CCD observations were made at the prime focus of the 3.6 m aperture CFHT telescope during the 1991 total solar eclipse.


Author(s):  
W. Krakow ◽  
W. C. Nixon

The scanning electron microscope (SEM) can be run at television scanning rates and used with a video tape recorder to observe dynamic specimen changes. With a conventional tungsten source, a low noise TV image is obtained with a field of view sufficient to cover the area of the specimen to be recorded. Contrast and resolution considerations have been elucidated and many changing specimens have been studied at TV rates.To extend the work on measuring the magnitude of charge and field distributions of small particles in the SEM, we have investigated their motion and electrostatic interaction at TV rates. Fig. 1 shows a time sequence of polystyrene spheres on a conducting grating surface inclined to the microscope axis. In (la) there are four particles present in the field of view, while in (lb) a fifth particle has moved into view.


Author(s):  
M. G. Lagally

It has been recognized since the earliest days of crystal growth that kinetic processes of all Kinds control the nature of the growth. As the technology of crystal growth has become ever more refined, with the advent of such atomistic processes as molecular beam epitaxy, chemical vapor deposition, sputter deposition, and plasma enhanced techniques for the creation of “crystals” as little as one or a few atomic layers thick, multilayer structures, and novel materials combinations, the need to understand the mechanisms controlling the growth process is becoming more critical. Unfortunately, available techniques have not lent themselves well to obtaining a truly microscopic picture of such processes. Because of its atomic resolution on the one hand, and the achievable wide field of view on the other (of the order of micrometers) scanning tunneling microscopy (STM) gives us this opportunity. In this talk, we briefly review the types of growth kinetics measurements that can be made using STM. The use of STM for studies of kinetics is one of the more recent applications of what is itself still a very young field.


Author(s):  
A. V. Crewe ◽  
J. Wall ◽  
L. M. Welter

A scanning microscope using a field emission source has been described elsewhere. This microscope has now been improved by replacing the single magnetic lens with a high quality lens of the type described by Ruska. This lens has a focal length of 1 mm and a spherical aberration coefficient of 0.5 mm. The final spot size, and therefore the microscope resolution, is limited by the aberration of this lens to about 6 Å.The lens has been constructed very carefully, maintaining a tolerance of + 1 μ on all critical surfaces. The gun is prealigned on the lens to form a compact unit. The only mechanical adjustments are those which control the specimen and the tip positions. The microscope can be used in two modes. With the lens off and the gun focused on the specimen, the resolution is 250 Å over an undistorted field of view of 2 mm. With the lens on,the resolution is 20 Å or better over a field of view of 40 microns. The magnification can be accurately varied by attenuating the raster current.


Author(s):  
Stephen R. Bolsover

The field of intracellular ion concentration measurement expanded greatly in the 1980's due primarily to the development by Roger Tsien of ratiometric fluorescence dyes. These dyes have many applications, and in particular they make possible to image ion concentrations: to produce maps of the ion concentration within living cells. Ion imagers comprise a fluorescence microscope, an imaging light detector such as a video camera, and a computer system to process the fluorescence signal and display the map of ion concentration.Ion imaging can be used for two distinct purposes. In the first, the imager looks at a field of cells, measuring the mean ion concentration in each cell of the many in the field of view. One can then, for instance, challenge the cells with an agonist and examine the response of each individual cell. Ion imagers are not necessary for this sort of experiment: one can instead use a system that measures the mean ion concentration in a just one cell at any one time. However, they are very much more convenient.


Author(s):  
B.G. Frost ◽  
D.C. Joy ◽  
L.F. Allard ◽  
E. Voelkl

A wide holographic field of view (up to 15 μm in the Hitachi-HF2000) is achieved in a TEM by switching off the objective lens and imaging the sample by the first intermediate lens. Fig.1 shows the corresponding ray diagram for low magnification image plane off-axis holography. A coherent electron beam modulated by the sample in its amplitude and its phase is superimposed on a plane reference wave by a negatively biased Möllenstedt-type biprism.Our holograms are acquired utilizing a Hitachi HF-2000 field emission electron microscope at 200 kV. Essential for holography are a field emission gun and an electron biprism. At low magnification, the excitation of each lens must be appropriately adjusted by the free lens control mode of the microscope. The holograms are acquired by a 1024 by 1024 slow-scan CCD-camera and processed by the “Holoworks” software. The hologram fringes indicate positively and negatively charged areas in a sample by the direction of the fringe bending (Fig.2).


Sign in / Sign up

Export Citation Format

Share Document