A STUDY ON HOW TO ELEVATE ORGANISATIONAL CREATIVITY IN TAIWANESE DESIGN ORGANISATION

2008 ◽  
Vol 12 (04) ◽  
pp. 699-723 ◽  
Author(s):  
WEN-CHIH CHANG ◽  
ZUN-HWA CHIANG

This research focuses on exploring which factors influence organisational creativity the most, and what actions are the most effective to enhance organisational creativity of design companies and departments in Taiwan. The survey showed that the most influential five factors to organisational creativity were in the order of design environment, team climate, group/organisation culture, design process and motive of work. The survey also showed that the most effective ways of improving organisational creativity were in the order of effective knowledge/experience sharing among colleagues, cultivating the designers' world view, accumulations of team design experiences, visiting domestic and foreign design exhibitions and diversified design work experiences. After the data from the questionnaire were further analysed by t-test, one-way ANOVA and Scheffé post hoc multiple comparisons, the study also showed that the most effective ways of improving organisational creativity were in the significant difference between the design company and design department. Furthermore, in terms of demographic variables of gender, employees' education, professional training, age and working experiences, the study result also implied that the most effective ways of improving organisational creativity could be different under different situations. With follow-up interview, we also found that due to the differences of business conditions, interviewees also had different perspectives referring to the definitions of good ideas. It drew various degrees of attentions when valuating creativity and improving it in the organisation. Thus, in order to get an effective creative performance, while facing different layout strategies and environments, administrators must adjust these measures to fit into their own need according to the conditions or restrictions of the organisations.

2013 ◽  
Vol 28 (1) ◽  
pp. 28-32 ◽  
Author(s):  
Matthew Wyon ◽  
Julie Harris ◽  
Derrick Brown ◽  
Frances Clarke

A lateral bias has been previously reported in dance training. The aim of this study was to investigate whether there are any bilateral differences in peak forces, power, and maximum knee flexion during a sequence of three grand jetés and how they relate to leg dominance. A randomised observational design was selected for the study. Volunteers consisted of 20 female dancers in the last year of pre-professional training. All volunteers completed three different tests to determine leg dominance prior to completing a three grande jeté sequence. The lead leg for the jump sequence was randomised. Peak take-off power, relative landing force (BW), and maximum knee flexion angles were measured using a Myotest accelerometer and integrated goniometer. Results indicated that 90% of dancers reported right leg dominance. A significant difference was noted in peak take-off power among the jumps (p<0.01); post hoc test indicated jump 3 was significantly greater than jump 1. Mean maximum take-off knee angles increased over the three-jump sequence with the left leg having a significantly deeper plié than the right (p<0.01). Landing data showed an increase in peak force and a decrease in maximum knee angles across the jump sequence. The present data indicate different bilateral strategies during take-off and landing during grand jetés in female dancers resulting in increased forces during the jumps on the non-dominant side. These differences need to be addressed by incorporating appropriate modifications in training methodology that eliminates the observed bilateral differences.


2012 ◽  
Vol 42 (2) ◽  
Author(s):  
Anton Budhi Darmawan ◽  
Dwi Utami Anjarwati

Background: Chronic suppurative otitis media (CSOM) is one infectious disease of the middle ear, most commonly caused by Pseudomonas aeruginosa. A high number of patients come to the ENT outpatient clinic with active benign type of CSOM. The bacteria Pseudomonas aeruginosa is capable of producing biofilm which protects itself from penetration of antibiotics, and therefore creates resistance towards antibiotics and difficult to eradicate. Objective: The aim of this study was to compare the sensitivity levels of chloramphenicol, polymyxin-neomycin, cyprofloxacin and ofloxacine against Pseudomonas aeruginosa in patients with active benign type CSOM in ENT clinic. Method: The method used was across sectional study on 25 patients, from August 2010 until December 2010. Samples were taken withear swab and then put on sensitivity test to chloramphenicol, polymyxin-neomycin, cyprofloxacin andofloxacine using the diffusion disc method. The analysis used in this study was Cochran test. Results: Results showed a significant difference in sensitivity among chloramphenicol (38,70%), polymyxinneomycin(83,87%),cyprofloxacin(90,32%)andofloxacin(58,06%)withp=0,000(p<0,05).PostHocanalysisusing the Mc Nemar indicated that there were significant differences in sensitivity betweenpolymyxin-neomycin to chloramphenicol with p=0,000 (p<0,05), ciprofloxacin to chloramphenicol andciprofloxacin to ofloxacine with p= 0,002, but there were no significant differences between cyprofloxacinto polymyxin-neomycin with p=0,687, polymyxin-neomycin to ofloxacin p=0.057 and ofloxacin tochloramphenicol p=0,109.   There were significant differences in antibiotic ear dropssensitivity to Pseudomonas aeruginosa in patients with active benign type of CSOM. Cyprofloxacin andpolymyxin-neomycin were more sensitive than ofloxacin and chloramphenicol. Keywords: Pseudomonas aeruginosa, active benign type of chronic suppurative otitis media, antibioticear drops.  Abstrak :  Latar belakang: Otitis media supuratif kronik (OMSK) merupakan penyakit infeksi kronik telinga tengah yang sering dijumpai di klinik THT. Penyebab tersering OMSK adalah bakteri Pseudomonasaeruginosa. Pseudomonas aeruginosa mempunyai kemampuan untuk membentuk biofilm yangmelindunginya dari penetrasi antibiotik sehingga menimbulkan resistensi terhadap antibiotik dan sulituntuk eradikasinya. Tujuan: Untuk mengetahui perbandingan tingkat sensitivitas kloramfenikol,polimiksin-neomisin, ciprofloksasin dan ofloksasin terhadap isolat Pseudomonas aeruginosa padapasien OMSK benigna aktif di klinik THT RSMS. Metode: Metode yang digunakan adalah crosssectional terhadap 29 pasien OMSK di klinik THT RSMS periode bulan Agustus 2010 - Desember2010. Pengambilan sampel dilakukan dengan swab telinga. Uji sensitivitas terhadap kloramfenikol,polimiksin-neomisin, ciprofloksasin dan ofloksasin dilakukan dengan metode cakram secara difusi.Analisis yang digunakan dalam penelitian ini adalah Cochran dan analisis post hoc. Hasil: Didapatkansensitivitas kloramfenikol sebesar 38,70%, polimiksin-neomisin sebesar 83,87%, ciprofloksasin sebesar90,32% dan ofloksasin sebesar 58,06% dengan p=0,01 (P<0,05), yang menunjukkan adanya perbedaansensitivitas yang bermakna antara kloramfenikol, polimiksin-neomisin, ciprofloksasin dan ofloksasinterhadap Pseudomonas aeruginosa. Analisis post hoc menggunakan Mc Nemar menunjukkan bahwaterdapat perbedaan sensitivitas yang bermakna antara tetes telinga polimiksin-neomisin terhadapkloramfenikol, dan ciprofloksasin terhadap kloramfenikol p=0,000 (p<0,05), serta terdapat perbedaanyang bermakna antara tetes telinga ciprofloksasin terhadap ofloksasin, p=0,002, tetapi tidak terdapatperbedaan yang bermakna antara ciprofloksasin terhadap polimiksin-neomisin, p=0,687, polimiksinneomisinterhadap ofloksasin p=0,057, dan kloramfenikol terhadap ofloksasin p=0,109. Kesimpulan:Terdapat perbedaan sensitivitas yang bermakna tetes telinga antibiotik terhadap Pseudomonas aeruginosa pada pasien OMSK benigna aktif. Ciprofloksasin dan polimiksin-neomisin tetes telinga mempunyai sensitivitas yang lebih baik dibanding ofloksasin dan kloramfenikol. Kata kunci: Pseudomonas aeruginosa, otitis media supuratif kronik, tetes telinga antibiotik 


Author(s):  
Mana Alqahtani

The aim was to assess the influence of moderate cigarette-smoking on the clinical (bleeding on probing [BoP] and probing depth [PD]) and radiographic (crestal bone resorption [CBR]) around cement- and screw-retained dental implants at 5 years’ follow-up. A questionnaire was used to collect information about age, gender, smoking history, duration of implants in function, jaw location of the implant, and daily toothbrushing and flossing. Peri-implant BoP, PD and CBR were measured in all groups. Group comparisons were performed using one-way analysis of variance and for multiple comparisons, the Bonferroni Post hoc adjustment test was performed. Level of significance was set at P&lt;0.05. Forty-eight patients (25 smokers and 23 non-smokers) had cement-retained dental implants; and 48 (24 smokers and 24 non-smokers) had screw-retained dental implants. Among patients with cement and screw-retained dental implants, PD (P&lt;0.05) and CBR (P&lt;0.05) were significantly higher among smokers than non-smokers. The peri-implant sites that demonstrated BoP were statistically significantly higher among non-smokers (P&lt;0.05) than smokers among patients with cement- and screw-retained dental implants. There was no statistically significant difference in peri-implant PD and CBR among smokers with cement- and screw-retained dental implants. Among non-smokers with cement and screw-retained dental implants, there was no statistically significant difference in BoP, PD and CBR. Cigarette-smoking is associated with an increased PD and CBR around cement- and screw-retained dental implants. Cigarette-smoking increases peri-implant soft tissue inflammation as well as loss of crestal bone and this relationship is independent of the type of implant retention protocol used.The author recommends that cement- and screw-retained dental implants are suitable for prosthesis restoration in non-smokers. Further studies on dual-smokers (individuals smoking cigarettes and other forms of tobacco products) are needed related to the clinicoradiographic inflammatory parameters around cement- and screw-retained dental implants


2020 ◽  
Vol 21 (2) ◽  
pp. 126-131
Author(s):  
Bhuvanachandra Pasupuleti ◽  
Vamshikrishna Gone ◽  
Ravali Baddam ◽  
Raj Kumar Venisetty ◽  
Om Prakash Prasad

Background: Clobazam (CLBZ) metabolized primarily by Cytochrome P-450 isoenzyme CYP3A4 than with CYP2C19, Whereas Levetiracetam (LEV) is metabolized by hydrolysis of the acetamide group. Few CYP enzymes are inhibited by Proton Pump Inhibitors (PPIs) Pantoprazole, Esomeprazole, and Rabeprazole in different extents that could affect drug concentrations in blood. The aim of the present study was to evaluate the effect of these PPIs on the plasma concentrations of LEV and CLBZ. Methods: Blood samples from 542 patients were included out of which 343 were male and 199 were female patients and were categorized as control and test. Plasma samples analyzed using an HPLC-UV method. Plasma concentrations were measured and compared to those treated and those not treated with PPIs. One way ANOVA and games Howell post hoc test used by SPSS 20 software. Results: CLBZ concentrations were significantly 10 folds higher in patients treated with Pantoprazole (P=0.000) and 07 folds higher in patients treated with Esmoprazole and Rabeprazole (P=0.00). Whereas plasma concentration of LEV control group has no statistical and significant difference when compared to pantoprazole (P=0.546) and with rabeprazole and esomeprazole was P=0.999. Conclusion: The effect of comedication with PPIs on the plasma concentration of clobazam is more pronounced for pantoprazole to a greater extent when compared to esomeprazole and rabeprazole. When pantoprazole is used in combination with clobazam, dose reduction of clobazam should be considered, or significance of PPIs is seen to avoid adverse effects.


Nutrients ◽  
2021 ◽  
Vol 13 (6) ◽  
pp. 1806
Author(s):  
Virginia Chan ◽  
Alyse Davies ◽  
Lyndal Wellard-Cole ◽  
Silvia Lu ◽  
Hoi Ng ◽  
...  

Technology-enhanced methods of dietary assessment may still face common limitations of self-report. This study aimed to assess foods and beverages omitted when both a 24 h recall and a smartphone app were used to assess dietary intake compared with camera images. For three consecutive days, young adults (18–30 years) wore an Autographer camera that took point-of-view images every 30 seconds. Over the same period, participants reported their diet in the app and completed daily 24 h recalls. Camera images were reviewed for food and beverages, then matched to the items reported in the 24 h recall and app. ANOVA (with post hoc analysis using Tukey Honest Significant Difference) and paired t-test were conducted. Discretionary snacks were frequently omitted by both methods (p < 0.001). Water was omitted more frequently in the app than in the camera images (p < 0.001) and 24 h recall (p < 0.001). Dairy and alternatives (p = 0.001), sugar-based products (p = 0.007), savoury sauces and condiments (p < 0.001), fats and oils (p < 0.001) and alcohol (p = 0.002) were more frequently omitted in the app than in the 24 h recall. The use of traditional self-report methods of assessing diet remains problematic even with the addition of technology and finding new objective methods that are not intrusive and are of low burden to participants remains a challenge.


Author(s):  
Álvaro Borrallo-Riego ◽  
Eleonora Magni ◽  
Juan Antonio Jiménez-Álvarez ◽  
Vicente Fernández-Rodríguez ◽  
María Dolores Guerra-Martín

The supervision of clinical placements is essential to achieving a positive learning experience in the clinical setting and which supports the professional training of those being supervised. The aim of this study was to explore health sciences students’ perceptions of the role of the supervisor in the supervision of clinical placements. A quantitative methodology was used, administering a previously validated questionnaire, by means of an expert panel and a pre-test, to 134 students from the Faculty of Nursing, Physiotherapy and Podiatry at the University of Seville (Spain). The analysis of variables was carried out by means of a data matrix. The results revealed a statistically significant difference in the perception of placement supervision depending on the degree, with Nursing producing the highest degree of affirmation in the variables studied and the greatest satisfaction with placement supervision; in contrast, Physiotherapy produced the greatest dissatisfaction and the lowest degree of affirmation. The study and analysis of these perceptions facilitates the collection of relevant information in order to formulate actions that help to improve the supervision experience during placements. They also allow a greater understanding of what factors most influence the experience of supervision during clinical placements.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Suvanjaa Sivalingam ◽  
Emil List Larsen ◽  
Daniel H. van Raalte ◽  
Marcel H. A. Muskiet ◽  
Mark M. Smits ◽  
...  

AbstractGlucagon-like peptide 1 receptor agonists have shown cardioprotective effects which have been suggested to be mediated through inhibition of oxidative stress. We investigated the effect of treatment with a glucagon-like peptide 1 receptor agonist (liraglutide) on oxidative stress measured as urinary nucleic acid oxidation in persons with type 2 diabetes. Post-hoc analysis of two independent, randomised, placebo-controlled and double-blinded clinical trials. In a cross-over study where persons with type 2 diabetes and microalbuminuria (LIRALBU, n = 32) received liraglutide (1.8 mg/day) or placebo for 12 weeks in random order, separated by 4 weeks of wash-out. In a parallel-grouped study where obese persons with type 2 diabetes (SAFEGUARD, n = 56) received liraglutide (1.8 mg/day), sitagliptin (100 mg/day) or placebo for 12 weeks. Endpoints were changes in the urinary markers of DNA oxidation (8-oxo-7,8-dihydro-2′-deoxyguanosine (8-oxodG)) and RNA oxidation [8-oxo-7,8-dihydroguanosine (8-oxoGuo)]. In LIRALBU, we observed no significant differences between treatment periods in urinary excretion of 8-oxodG [0.028 (standard error (SE): 0.17] nmol/mmol creatinine, p = 0.87) or of 8-oxoGuo [0.12 (0.12) nmol/mmol creatinine, p = 0.31]. In SAFEGUARD, excretion of 8-oxodG was not changed in the liraglutide group [2.8 (− 8.51; 15.49) %, p = 0.62] but a significant decline was demonstrated in the placebo group [12.6 (− 21.3; 3.1) %, p = 0.02], resulting in a relative increase in the liraglutide group compared to placebo (0.16 nmol/mmol creatinine, SE 0.07, p = 0.02). Treatment with sitagliptin compared to placebo demonstrated no significant difference (0.07 (0.07) nmol/mmol creatinine, p = 0.34). Nor were any significant differences for urinary excretion of 8-oxoGuo liraglutide vs placebo [0.09 (SE: 0.07) nmol/mmol creatinine, p = 0.19] or sitagliptin vs placebo [0.07 (SE: 0.07) nmol/mmol creatinine, p = 0.35] observed. This post-hoc analysis could not demonstrate a beneficial effect of 12 weeks of treatment with liraglutide or sitagliptin on oxidatively generated modifications of nucleic acid in persons with type 2 diabetes.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Ádám László Nagy ◽  
Zsolt Tóth ◽  
Tamás Tarjányi ◽  
Nándor Tamás Práger ◽  
Zoltán Lajos Baráth

Abstract Background In this research the biomechanical properties of a bone model was examined. Porcine ribs are used as experimental model. The objective of this research was to investigate and compare the biomechanical properties of the bone model before and after implant placement. Methods The bone samples were divided in three groups, Group 1 where ALL-ON-FOUR protocol was used during pre-drilling and placing the implants, Group 2 where ALL-ON-FOUR protocol was used during pre-drilling, and implants were not placed, and Group 3 consisting of intact bones served as a control group. Static and dynamic loading was applied for examining the model samples. Kruskal–Wallis statistical test and as a post-hoc test Mann–Whitney U test was performed to analyze experimental results. Results According to the results of the static loading, there was no significant difference between the implanted and original ribs, however, the toughness values of the bones decreased largely on account of predrilling the bones. The analysis of dynamic fatigue measurements by Kruskal–Wallis test showed significant differences between the intact and predrilled bones. Conclusion The pre-drilled bone was much weaker in both static and dynamic tests than the natural or implanted specimens. According to the results of the dynamic tests and after a certain loading cycle the implanted samples behaved the same way as the control samples, which suggests that implantation have stabilized the skeletal bone structure.


2020 ◽  
Vol 57 (6) ◽  
pp. 341-347
Author(s):  
Jaeyeon Chung ◽  
Sang-Hwan Ji ◽  
Young-Eun Jang ◽  
Eun-Hee Kim ◽  
Ji-Hyun Lee ◽  
...  

Near-infrared spectroscopy devices can measure peripheral tissue oxygen saturation (StO<sub>2</sub>). This study aims to compare StO<sub>2</sub> using INVOS® and different O3™ settings (O3<sup>25:75</sup> and O3<sup>30:70</sup>). Twenty adults were recruited. INVOS® and O3™ probes were placed simultaneously on 1 side of forearm. After baseline measurement, the vascular occlusion test was initiated. The baseline value, rate of deoxygenation and reoxygenation, minimum and peak StO<sub>2</sub>, and time from cuff release to peak value were measured. The parameters were compared using ANOVA and Kruskal-Wallis tests. Bonferroni’s correction and Mann-Whitney pairwise comparison were used for post hoc analysis. The agreement between StO<sub>2</sub> of devices was evaluated using Bland-Altman plots. INVOS® baseline value was higher (79.7 ± 6.4%) than that of O3<sup>25:75</sup> and O3<sup>30:70</sup> (62.4 ± 6.0% and 63.7 ± 5.5%, respectively, <i>p</i> &#x3c; 0.001). The deoxygenation rate was higher with INVOS® (10.6 ± 2.1%/min) than with O3<sup>25:75</sup> and O3<sup>30:70</sup> (8.4 ± 2.2%/min, <i>p</i> = 0.006 and 7.5 ± 2.1%/min, <i>p</i> &#x3c; 0.001). The minimum and peak StO<sub>2</sub> were higher with INVOS®. No significant difference in the reoxygenation rate was found between the devices and settings. The time to reach peak after cuff deflation was faster with INVOS® (both <i>p</i> &#x3c; 0.001). Other parameters were similar. There were no differences between the different O3™ settings. There were differences in StO<sub>2</sub> measurements between the devices, and these devices should not be interchanged. Differences were not observed between O3™ device settings.


2018 ◽  
Vol 128 (1) ◽  
pp. 120-125 ◽  
Author(s):  
Robert F. Spetzler ◽  
Joseph M. Zabramski ◽  
Cameron G. McDougall ◽  
Felipe C. Albuquerque ◽  
Nancy K. Hills ◽  
...  

OBJECTIVEThe Barrow Ruptured Aneurysm Trial (BRAT) is a prospective, randomized trial in which treatment with clipping was compared to treatment with coil embolization. Patients were randomized to treatment on presentation with any nontraumatic subarachnoid hemorrhage (SAH). Because all other randomized trials comparing these 2 types of treatments have been limited to saccular aneurysms, the authors analyzed the current BRAT data for this subgroup of lesions.METHODSThe primary BRAT analysis included all sources of SAH: nonaneurysmal lesions; saccular, blister, fusiform, and dissecting aneurysms; and SAHs from an aneurysm associated with either an arteriovenous malformation or a fistula. In this post hoc review, the outcomes for the subgroup of patients with saccular aneurysms were further analyzed by type of treatment. The extent of aneurysm obliteration was adjudicated by an independent neuroradiologist not involved in treatment.RESULTSOf the 471 patients enrolled in the BRAT, 362 (77%) had an SAH from a saccular aneurysm. Patients with saccular aneurysms were assigned equally to the clipping and the coiling cohorts (181 each). In each cohort, 3 patients died before treatment and 178 were treated. Of the 178 clip-assigned patients with saccular aneurysms, 1 (1%) was crossed over to coiling, and 64 (36%) of the 178 coil-assigned patients were crossed over to clipping. There was no statistically significant difference in poor outcome (modified Rankin Scale score > 2) between these 2 treatment arms at any recorded time point during 6 years of follow-up. After the initial hospitalization, 1 of 241 (0.4%) clipped saccular aneurysms and 21 of 115 (18%) coiled saccular aneurysms required retreatment (p < 0.001). At the 6-year follow-up, 95% (95/100) of the clipped aneurysms were completely obliterated, compared with 40% (16/40) of the coiled aneurysms (p < 0.001). There was no difference in morbidity between the 2 treatment groups (p = 0.10).CONCLUSIONSIn the subgroup of patients with saccular aneurysms enrolled in the BRAT, there was no significant difference between modified Rankin Scale outcomes at any follow-up time in patients with saccular aneurysms assigned to clipping compared with those assigned to coiling (intent-to-treat analysis). At the 6-year follow-up evaluation, rates of retreatment and complete aneurysm obliteration significantly favored patients who underwent clipping compared with those who underwent coiling.Clinical trial registration no.: NCT01593267 (clinicaltrials.gov)


Sign in / Sign up

Export Citation Format

Share Document