Rapid insulin sensitivity test (RIST)

1998 ◽  
Vol 76 (12) ◽  
pp. 1080-1086 ◽  
Author(s):  
W Wayne Lautt ◽  
Xiaowsi Wang ◽  
Parissa Sadri ◽  
Dallas J Legare ◽  
M Paula Macedo

A rapid insulin sensitivity test (RIST) was recently introduced to assess insulin action in vivo (H. Xie, L. Zhu, Y.L. Zhang, D.J. Legare, and W.W. Lautt. J. Pharmacol. Toxicol. Methods, 35: 77-82. 1996). This technical report describes the current recommended standard operating procedure for the use of the RIST in rats based upon additional experience with approximately 100 tests. We describe the manufacture and use of an arterial-venous shunt that allows rapid multiple arterial samples and intravenous administration of drugs. The RIST procedure involves determination of a stable arterial glucose baseline to define the ideal euglycemic level to be maintained following a 5-min infusion of insulin, with the RIST index being the amount of glucose required to be infused to maintain euglycemia over the test period. Insulin administration by a 5-min infusion is preferable to a 30-s bolus administration. No significant difference was determined between the use of Toronto pork-beef or human insulin. Four consecutive RISTs were carried out in the same animal over 4-5 h with no tendency for change with time. The RIST index is sufficiently sensitive and reproducible to permit establishment of insulin dose-response curves and interference of insulin action by elimination of hepatic parasympathetic nerves, using atropine. This technical report provides the current recommended standard operating procedure for the RIST.Key words: insulin, resistance, test, methodology, glucose.

2018 ◽  
Vol 71 (suppl 3) ◽  
pp. 1205-1211
Author(s):  
Alessandra Madalena Garcia Santos ◽  
Claudia Silveira Viera ◽  
Beatriz Rosana Gonçalves de Oliveira Toso ◽  
Grasiely Masotti Scalabrin Barreto ◽  
Sarah Nancy Deggau Hegeto de Souza

ABSTRACT Objective: To compare the physiological and behavioral responses of Premature Infant (PREEMIE) positioned by the Unit Routine Decubitus (URD) and the Standard Operating Procedure (SOP). Method: A quasi-experimental comparative study performed at a Neonatal Intensive Care Unit in Southern Brazil. We evaluated 30 PREEMIEs with gestational age ≤32 weeks, randomly assigned to Unit Routine Decubitus (URD) and Intervention Group (IG), subdivided into Right Lateral Decubitus (RLD), Dorsal Decubitus (DD), Left Lateral Decubitus (LLD) and Ventral Decubitus (VD). It was evaluated before, during and after the procedure: Heart Rate (HR); Respiratory Frequency (RF); Peripheral Oxygen Saturation (SpO2); behavior by the Neonatal Behavioral Assessment Scale (NBAS); by NIPS. Results: During the intervention, RR (p = 0.023), indexes in NBAS (p = 0.01) and NIPS (p <0.0001) reduced significantly in SOP. HR and SpO2 did not present a significant difference. Conclusion: Positioning according to the SOP shows benefit in relation to the behavioral and physiological status of PREEMIE.


Author(s):  
Wahyu Wahyu Wahyu ◽  
Marliyati Marliyati Marliyati ◽  
I. Nyoman Romangsi

The aim of this article is to analyze internal control in service company. The analyze used the components of internal control according to COSO: control environment, risk assessment, control activities, information and communication, monitoring. Analysis of internal control used the data obtained through observation, questionnaires, interview, and documentary. Based on this analysis results can be concluded, that the dual positions refer with company SOP (Standard Operating Procedure). Separation of task does not work because that the dual positions. Therefore, the component of control activities applied at company is not in accordance with the component of control activities according to COSO. Nonconformity components still results in very effective internal control because the purpose of the internal control still remains to be achieved even though there are components that are not in accordance with the internal control components according to COSO.


2018 ◽  
Vol 7 (2) ◽  
pp. 95
Author(s):  
Indrastuti Indrastuti ◽  
Fatmawaty Damrah

2020 ◽  
pp. 33-38
Author(s):  
N. Katkasova ◽  
L. Pudovinnikova

This standard operating procedure (SOP) determines the standard process of filling out questionnaire by a nurse, it is introduced into the practice of nursing staff of the Samara City Clinical Polyclinic No. 15.


2020 ◽  
pp. 64-66
Author(s):  
Svetlana Dashuk

This standard operating procedure (SOP) defines the establishment of uniform requirements to compliance with the procedure for carrying out hygienic treatment of hands, has been introduced into the practical activities of medical workers of Tolyattin dental polyclinic No. 3.


2020 ◽  
pp. 71-74
Author(s):  
Svetlana Dashuk

This standard operating procedure (DIS) defines the establishment of uniform requirements for compliance with the procedure for carrying out current and general cleaning in the premises, has been put into practice by cleaners of the office premises of Tolyattin dental polyclinic No. 3.


Sign in / Sign up

Export Citation Format

Share Document