A Quantum Chemical Conformational Analysis of the Ethylenediamine Molecule

1972 ◽  
Vol 50 (7) ◽  
pp. 1005-1007 ◽  
Author(s):  
N. Hadjiliadis ◽  
A. Diot ◽  
T. Theophanides

The conformational analysis of the ethylenediamine molecule has been studied by the LCAO-EHMO calculation method. The results indicate that the most stable conformation of the molecule is the gauche form, in which the angle N—C—C—N is ca. 63.0° measured from the cis form. This is in agreement with experimental data and can explain the fact that the ethylenediamine in its chelate complexes is always in the gauche form. In addition, the present results indicate that the trans form is the next most stable conformation of ethylenediamine in agreement with experimental results on bridging ethylenediamine metal complexes.

1985 ◽  
Vol 50 (4) ◽  
pp. 920-929 ◽  
Author(s):  
Jiří Sedláček

CNDO/2 calculations for simple models of adsorption and dehydration reactions of secondary aliphatic and aromatic alcohols on polar catalysts are presented. The models involve selected stages of elimination mechanisms of various types (E1, E2 and E1cB elimination). Calculated quantum chemical quantities were correlated with reported experimental data. It is shown that reactivities for the series of substituted phenylethanols correlate very well with the ease of carbonium ion formation. In the case of aliphatic alcohols, calculated quantities correlate generally with the reactivities on SiO2 and are in anticorrelation with the reactivities on Al2O3.NaOH.


Molecules ◽  
2021 ◽  
Vol 26 (5) ◽  
pp. 1321
Author(s):  
Yasunobu Asawa ◽  
Aleksandra V. Arsent’eva ◽  
Sergey A. Anufriev ◽  
Alexei A. Anisimov ◽  
Kyrill Yu. Suponitsky ◽  
...  

Bis(carboranyl)amides 1,1′-μ-(CH2NH(O)C(CH2)n-1,2-C2B10H11)2 (n = 0, 1) were prepared by the reactions of the corresponding carboranyl acyl chlorides with ethylenediamine. Crystal molecular structure of 1,1′-μ-(CH2NH(O)C-1,2-C2B10H11)2 was determined by single crystal X-ray diffraction. Treatment of bis(carboranyl)amides 1,1′-μ-(CH2NH(O)C(CH2)n-1,2-C2B10H11)2 with ammonium or cesium fluoride results in partial deboronation of the ortho-carborane cages to the nido-carborane ones with formation of [7,7′(8′)-μ-(CH2NH(O)C(CH2)n-7,8-C2B9H11)2]2−. The attempted reaction of [7,7′(8′)-μ-(CH2NH(O)CCH2-7,8-C2B9H11)2]2− with GdCl3 in 1,2-dimethoxy- ethane did not give the expected metallacarborane. The stability of different conformations of Gd-containing metallacarboranes has been estimated by quantum-chemical calculations using [3,3-μ-DME-3,3′-Gd(1,2-C2B9H11)2]− as a model. It was found that in the most stable conformation the CH groups of the dicarbollide ligands are in anti,anti-orientation with respect to the DME ligand, while any rotation of the dicarbollide ligand reduces the stability of the system. This makes it possible to rationalize the design of carborane ligands for the synthesis of gadolinium metallacarboranes on their base.


1983 ◽  
Vol 105 (1) ◽  
pp. 29-33 ◽  
Author(s):  
A. M. Clausing

Cavity solar receivers are generally believed to have higher thermal efficiencies than external receivers due to reduced losses. A simple analytical model was presented by the author which indicated that the ability to heat the air inside the cavity often controls the convective loss from cavity receivers. Thus, if the receiver contains a large amount of inactive hot wall area, it can experience a large convective loss. Excellent experimental data from a variety of cavity configurations and orientations have recently become available. These data provided a means of testing and refining the analytical model. In this manuscript, a brief description of the refined model is presented. Emphasis is placed on using available experimental evidence to substantiate the hypothesized mechanisms and assumptions. Detailed comparisons are given between analytical predictions and experimental results. Excellent agreement is obtained, and the important mechanisms are more clearly delineated.


1993 ◽  
Vol 16 (2) ◽  
pp. 63-70 ◽  
Author(s):  
N.A. Hoenich ◽  
P.T. Smirthwaite ◽  
C. Woffindin ◽  
P. Lancaster ◽  
T.H. Frost ◽  
...  

Recirculation is an important factor in single needle dialysis and, if high, can compromise treatment efficiency. To provide information regarding recirculation characteristics of access devices used in single needle dialysis, we have developed a new technique to characterise recirculation and have used this to measure the recirculation of a Terumo 15G fistula needle and a VasCath SC2300 single lumen catheter. The experimentally obtained results agreed well with those established clinically (8.5 ± 2.4% and 18.4 ± 3.4%). The experimental results have also demonstrated a dependence on access type, pump speeds and fistula flow rate. A comparison of experimental data with theoretical predictions showed that the latter exceeded those measured with the largest contribution being due to the experimental fistula.


Author(s):  
Farrokh Zarifi-Rad ◽  
Hamid Vajihollahi ◽  
James O’Brien

Scale models give engineers an excellent understanding of the aerodynamic behavior behind their design; nevertheless, scale models are time consuming and expensive. Therefore computer simulations such as Computational Fluid Dynamics (CFD) are an excellent alternative to scale models. One must ask the question, how close are the CFD results to the actual fluid behavior of the scale model? In order to answer this question the engineering team investigated the performance of a large industrial Gas Turbine (GT) exhaust diffuser scale model with performance predicted by commercially available CFD software. The experimental results were obtained from a 1:12 scale model of a GT exhaust diffuser with a fixed row of blades to simulate the swirl generated by the last row of turbine blades five blade configurations. This work is to validate the effect of the turbulent inlet conditions on an axial diffuser, both on the experimental front and on the numerical analysis approach. The object of this work is to bring forward a better understanding of velocity and static pressure profiles along the gas turbine diffusers and to provide an accurate experimental data set to validate the CFD prediction. For the CFD aspect, ANSYS CFX software was chosen as the solver. Two different types of mesh (hexagonal and tetrahedral) will be compared to the experimental results. It is understood that hexagonal (HEX) meshes are more time consuming and more computationally demanding, they are less prone to mesh sensitivity and have the tendancy to converge at a faster rate than the tetrahedral (TET) mesh. It was found that the HEX mesh was able to generate more consistent results and had less error than TET mesh.


2010 ◽  
Vol 24 (18) ◽  
pp. 1963-1970 ◽  
Author(s):  
ARVIDS STASHANS ◽  
RICHARD RIVERA

Structural and optical properties of F-center (two electrons trapped by an oxygen vacancy) defect in hematite have been studied using a quantum-chemical model. Calculated absorption energies, 0.9 eV and 3.6 eV, are discussed in terms of the available experimental data. An explanation for the origin of experimentally observed electron depletion in hematite is proposed.


2014 ◽  
Vol 698 ◽  
pp. 466-471
Author(s):  
Oleg V. Panchenko ◽  
Alexey M. Levchenko ◽  
Victor A. Karkhin

Specimens of various sizes are used to determine hydrogen content in deposited metals in such standards as ISO 3690, AWS A 4.3, and GOST 23338 while measuring methods are the same. It causes problems in comparison of experimental results and brings up the following question: what kind of specimen size is optimal to determine hydrogen content? An optimal specimen size was estimated using a calculation method. Experimental and calculation results obtained by using specimens with estimated dimensions were compared to the results obtained by using the specimen with dimensions of 100*25*8 mm to determine hydrogen content in a deposited metal.


Sign in / Sign up

Export Citation Format

Share Document